Rooflight and Skylight Guides

What these guides are for These are the pages we would otherwise be reading out on the phone. Each one takes a single piece of rooflight or skylight detail — kerb height, rafter depth, flashing kits, U-values, actuator types, tunnel reflectivity — and explains what it does, what goes wrong when it is got wrong, […]

1930s Poole semis with internal bathrooms and no wall to reach
The roof end: a small dome that needs its own flashing like any other opening.
Start here

1930s Poole semis with internal bathrooms and no wall to reach

The interwar semi built across Parkstone, Winton, Penn Hill and Oakdale has a recognisable problem: a bathroom in the middle of the first floor with no external wall, no window, and nothing above it…

Read the guide

sun-tunnel-installation

12 guides
1930s Poole semis with internal bathrooms and no wall to reach
Daylight into a bathroom with no outside wall to put a window in.
Guide

1930s Poole semis with internal bathrooms and no wall to reach

The interwar semi built across Parkstone, Winton, Penn Hill and Oakdale has a recognisable problem: a bathroom in the middle…

Adding a light kit so the tunnel works after dark
Two small apertures spread light better than one larger one in a shallow ceiling void.
Guide

Adding a light kit so the tunnel works after dark

A sun tunnel goes dark when the sky does. In a bathroom or a hall that had no daylight at…

Broadstone bungalows where the loft void is shallow and wide
A landing that had no daylight of its own at all.
Guide

Broadstone bungalows where the loft void is shallow and wide

Broadstone, Creekmoor and the bungalow runs out towards Corfe Mullen were built low and built wide. Every room sits on…

Ceiling position: aiming a tunnel at the light you actually need
The roof end: a small dome that needs its own flashing like any other opening.
Guide

Ceiling position: aiming a tunnel at the light you actually need

Almost every sun tunnel gets put in the middle of the ceiling, and in perhaps half of those rooms the…

Condensation in a sun tunnel and the insulation sleeve that stops it
A short straight run loses far less light than a long bent one.
Guide

Condensation in a sun tunnel and the insulation sleeve that stops it

A sun tunnel drips because a cold surface has met warm wet air, not because the roof is leaking. The…

Diffuser choice and the difference between soft light and a glare spot
The kerb is measured before anything is ordered.
Guide

Diffuser choice and the difference between soft light and a glare spot

The diffuser is the only part of a sun tunnel anyone in the room ever sees, and it decides more…

Flashings for a sun tunnel on tile, slate and a flat roof
A prepared kerb, squared and weatherproofed, before the unit goes on.
Guide

Flashings for a sun tunnel on tile, slate and a flat roof

Almost everything that goes wrong with a sun tunnel at roof level is a flashing decision made badly, and almost…

How a rigid sun tunnel out-performs a flexible one over distance
Daylight into a bathroom with no outside wall to put a window in.
Guide

How a rigid sun tunnel out-performs a flexible one over distance

Over a short, straight drop between a roof plane and the ceiling below it, a flexible sun tunnel and a…

Reflectivity percentages and the light lost at every bend
Two small apertures spread light better than one larger one in a shallow ceiling void.
Guide

Reflectivity percentages and the light lost at every bend

A reflectivity figure on a sun tunnel data sheet is a real, measured property of the tube wall. What it…

Routing a tunnel through a loft full of services and storage
A landing that had no daylight of its own at all.
Guide

Routing a tunnel through a loft full of services and storage

A sun tunnel route is the answer to a geometry problem with two fixed points and a loft full of…

Tunnel diameter against room size: what 250mm and 350mm give
The roof end: a small dome that needs its own flashing like any other opening.
Guide

Tunnel diameter against room size: what 250mm and 350mm give

Of everything you can choose about a sun tunnel, diameter does the most work. It sets how much light enters,…

Where a sun tunnel beats a rooflight, and where it does not
A short straight run loses far less light than a long bent one.
Guide

Where a sun tunnel beats a rooflight, and where it does not

A sun tunnel is not a small rooflight. It is a different product solving a different problem, and the single…

roof-window-installation

12 guides
1930s semis in Poole: rafter spacing and the window sizes it allows
The flashing kit is chosen for the covering profile, not the window.
Guide

1930s semis in Poole: rafter spacing and the window sizes it allows

Half of suburban Poole was built to one drawing Between the wars the town spread outwards fast, and it spread…

Batten gauge, tile course and lining a window up with the roof
In the slope of the ceiling, daylight reaches further into the room than a dormer.
Guide

Batten gauge, tile course and lining a window up with the roof

You can see a badly set out window from the pavement Stand on any residential street in Poole and look…

Fitting a roof window without stripping the whole roof covering
Two spaced openings light a long room more evenly than one large one.
Guide

Fitting a roof window without stripping the whole roof covering

Nobody strips a roof to put a window in it It is a common worry and it comes from a…

Flashing kits for plain tile, pantile and slate, and where they differ
Set in the plane of the covering, with the flashing matched to the slate.
Guide

Flashing kits for plain tile, pantile and slate, and where they differ

The window is not what keeps the water out A roof window is a sealed box with glass in it.…

Head height, sill height and how the position frames a view
A profiled tile needs a deeper flashing than a slate does.
Guide

Head height, sill height and how the position frames a view

A window in a slope aims itself A wall window is neutral. It faces where the wall faces, and moving…

Insulation at the window perimeter and the cold corner it prevents
The kerb is measured before anything is ordered.
Guide

Insulation at the window perimeter and the cold corner it prevents

The dark line in the corner of a new reveal About eighteen months after a roof window goes in, a…

Plasterboard reveals that throw light into the room, not the wall
A prepared kerb, squared and weatherproofed, before the unit goes on.
Guide

Plasterboard reveals that throw light into the room, not the wall

The plasterboard does as much of the work as the glass Two identical roof windows, same size, same slope, same…

Purbeck stone slate roofs and the flashing detail they demand
The flashing kit is chosen for the covering profile, not the window.
Guide

Purbeck stone slate roofs and the flashing detail they demand

A roof made out of the hill behind it Drive west from Poole across the harbour and the roofs change…

Roof pitch limits: what happens below 15 degrees and above 55
In the slope of the ceiling, daylight reaches further into the room than a dormer.
Guide

Roof pitch limits: what happens below 15 degrees and above 55

Two limits, and they fail in opposite directions Every roof window carries a pitch range, and both ends of it…

Setting a roof window between rafters without cutting the structure
Two spaced openings light a long room more evenly than one large one.
Guide

Setting a roof window between rafters without cutting the structure

The loft decides the width, not the brochure A roof window’s width is settled by whoever framed the roof, usually…

Trimming a rafter for a wider window: the beams that take the load
Set in the plane of the covering, with the flashing matched to the slate.
Guide

Trimming a rafter for a wider window: the beams that take the load

Trimming, in the sense a carpenter means it Trimming a roof has nothing to do with tidying edges. It means…

Underlay, drape and the gap that stops water tracking behind a window
A profiled tile needs a deeper flashing than a slate does.
Guide

Underlay, drape and the gap that stops water tracking behind a window

The wet patch is rarely where the water got in Somebody rings about a damp corner of plasterboard a metre…

walk-on-rooflight-installation

12 guides
Anti slip surfaces and the frit pattern that stays grippy when wet
From beneath, it is the only daylight that room has.
Guide

Anti slip surfaces and the frit pattern that stays grippy when wet

Slip resistance on a walk-on rooflight is not an opinion about texture. It is a measured number, taken with a…

Balustrades, edge protection and where a walk-on panel changes the rules
Lit from the room below, it becomes the light in the terrace.
Guide

Balustrades, edge protection and where a walk-on panel changes the rules

Most of the difficulty in a walk-on project is not the glass. It is what happens at the edge of…

Flush thresholds, drainage channels and a terrace that does not pond
The laminated build-up is the structure, not a finish.
Guide

Flush thresholds, drainage channels and a terrace that does not pond

Water has exactly one job on a walk-on terrace, which is to leave. A non-trafficked rooflight does that with a…

Getting daylight down a light well without losing it to the walls
The frame carries the load; the glass only has to span it.
Guide

Getting daylight down a light well without losing it to the walls

A light well is not a window. It is a shaft, and a shaft is a lamp made mostly of…

How walk-on glass ages once a terrace has had a season of use
Structural glass set flush in a terrace, lighting the room beneath.
Guide

How walk-on glass ages once a terrace has had a season of use

A walk-on rooflight looks its best on the day it is commissioned and never looks quite like that again. That…

Old Town Poole basements and the pavement lights above them
The kerb is measured before anything is ordered.
Guide

Old Town Poole basements and the pavement lights above them

Walk through the older streets around Poole Quay and look down. Set into the pavement outside a number of buildings…

Point load, distributed load and the numbers a walk-on unit must meet
A prepared kerb, squared and weatherproofed, before the unit goes on.
Guide

Point load, distributed load and the numbers a walk-on unit must meet

There is no single number that describes what a walk-on rooflight will hold. There are two numbers, owned by two…

Sandbanks roof terraces and glass that takes salt and bare feet
From beneath, it is the only daylight that room has.
Guide

Sandbanks roof terraces and glass that takes salt and bare feet

A walk-on rooflight on a Sandbanks terrace is asked to do two jobs that pull against each other. For six…

Steel framing for a walk-on opening in an existing flat roof
Lit from the room below, it becomes the light in the terrace.
Guide

Steel framing for a walk-on opening in an existing flat roof

The glass is the easy part of a walk-on rooflight. The hard part is that you are cutting a hole…

Structural glass build-up: how many laminated layers carry a person
The laminated build-up is the structure, not a finish.
Guide

Structural glass build-up: how many laminated layers carry a person

A walk-on rooflight carries a person because it is not one piece of glass. It is three or four panes…

Thermal performance of a walk-on unit against a standard rooflight
The frame carries the load; the glass only has to span it.
Guide

Thermal performance of a walk-on unit against a standard rooflight

Owners expect a walk-on rooflight to perform like the rest of their glazing and are surprised when it does not.…

Trafficked but not walk-on: the units people mistake for each other
Structural glass set flush in a terrace, lighting the room beneath.
Guide

Trafficked but not walk-on: the units people mistake for each other

A good proportion of walk-on enquiries start with somebody standing on a roof looking at a rooflight and wondering whether…

energy-efficient-rooflights

12 guides
Argon and krypton fills matter less than the brochure suggests
A neutral coating you can just see at an angle, and barely at all from below.
Guide

Argon and krypton fills matter less than the brochure suggests

The cheapest line on the specification is usually the loudest Argon fill appears on almost every glazing quotation in the…

Condensation on the inside of the glass is a humidity problem
Clear glass on a south slope in July. The light is the problem, not the heat alone.
Guide

Condensation on the inside of the glass is a humidity problem

A week with a hygrometer settles it faster than an argument Almost every conversation about a wet skylight starts in…

G-value and solar gain: why a summer room refuses to cool down
The result the specification is aiming at: even light, no hot patch.
Guide

G-value and solar gain: why a summer room refuses to cool down

Nine in the evening, and the room is still the hottest in the house This is the complaint, almost word…

Part L, SAP and how a rooflight is counted in the calculation
Shade stops heat outside the glass, where it is still cheap to stop.
Guide

Part L, SAP and how a rooflight is counted in the calculation

“Does it meet Part L” is three different questions The question arrives as though there were a single standard a…

Pine canopy shading in Branksome Park and the glazing it allows
A warm-edge unit on a cold morning: clear glass, dry reveal.
Guide

Pine canopy shading in Branksome Park and the glazing it allows

The canopy is part of the roof build-up, whether or not it is on the drawing Walk a street in…

Rooflight area against floor area, and the daylight factor behind it
The kerb is measured before anything is ordered.
Guide

Rooflight area against floor area, and the daylight factor behind it

How big should it be, and the sum hiding behind the question It is the first question on almost every…

Solar control coatings: how they filter without dimming the room
A prepared kerb, squared and weatherproofed, before the unit goes on.
Guide

Solar control coatings: how they filter without dimming the room

Sunlight is not one thing, and that is the whole trick If sunlight were a single substance, filtering the heat…

South west facing roofs over Poole Harbour and the glare they catch
A neutral coating you can just see at an angle, and barely at all from below.
Guide

South west facing roofs over Poole Harbour and the glare they catch

Glare and heat are two different complaints People ring about a rooflight with what sounds like one problem and is…

Triple glazing on a rooflight: weight, U-value and diminishing return
Clear glass on a south slope in July. The light is the problem, not the heat alone.
Guide

Triple glazing on a rooflight: weight, U-value and diminishing return

The steps are not the same size Almost every argument about triple glazing goes wrong in the same place: it…

Vapour control layers, and the damp patch that is not a leak
The result the specification is aiming at: even light, no hot patch.
Guide

Vapour control layers, and the damp patch that is not a leak

It appears in October and it dries in April There is a particular sort of damp patch that behaves nothing…

Warm edge spacers and the cold strip around the glass
Shade stops heat outside the glass, where it is still cheap to stop.
Guide

Warm edge spacers and the cold strip around the glass

Look at where the water was, not at how much there is A rooflight running with condensation in January tells…

What a rooflight U-value covers and what it quietly leaves out
A warm-edge unit on a cold morning: clear glass, dry reveal.
Guide

What a rooflight U-value covers and what it quietly leaves out

Two quotes, two numbers, and not the same test Two firms price the same opening. One comes back with a…

conservation-rooflight-installation

12 guides
Article 4 directions and the permitted development they remove
The single central bar and the slim upstand are what the profile depends on.
Guide

Article 4 directions and the permitted development they remove

Two houses on the same street, the same age, the same roof. One has a pair of skylights in the…

Cast iron look frames, glazing bars and the details officers look for
A small aperture in a thick roof still lights a room, because it is glass not tile.
Guide

Cast iron look frames, glazing bars and the details officers look for

A case officer assessing a rooflight is not comparing brands. They are looking at a small number of physical details…

Listed building consent when the rooflight is on a rear slope
Spaced along the slope, they read as part of the roof rather than additions.
Guide

Listed building consent when the rooflight is on a rear slope

Almost every enquiry we take about a listed roof opens the same way: it is round the back, nobody can…

Poole Old Town conservation area and the roofs inside it
Recessed so the glass sits close to the plane of the slate.
Guide

Poole Old Town conservation area and the roofs inside it

The Old Town is the part of Poole that looks like Poole. It runs back from the Quay through the…

Purbeck stone slates and rooflights that respect the roof around them
On a listed or conservation-area roof, the profile is the whole argument.
Guide

Purbeck stone slates and rooflights that respect the roof around them

A Purbeck stone slate roof is the most demanding covering this firm works on, and the demand has nothing to…

Rear slopes, side slopes and the elevation a planner looks at first
The kerb is measured before anything is ordered.
Guide

Rear slopes, side slopes and the elevation a planner looks at first

Almost every conversation about a rooflight in a sensitive area reduces, within two minutes, to a question about which slope…

Secondary glazing, a single glazed look and the modern unit behind it
A prepared kerb, squared and weatherproofed, before the unit goes on.
Guide

Secondary glazing, a single glazed look and the modern unit behind it

On a small number of buildings an officer will want the rooflight to read as single glazed. Not literally single…

Sitting a conservation rooflight flush with the tile or slate line
The single central bar and the slim upstand are what the profile depends on.
Guide

Sitting a conservation rooflight flush with the tile or slate line

Water runs downhill and finds anything that lets it stop. That single fact governs the whole of this detail, and…

The Jurassic Coast World Heritage Site and roofs in its setting
A small aperture in a thick roof still lights a room, because it is glass not tile.
Guide

The Jurassic Coast World Heritage Site and roofs in its setting

The Jurassic Coast runs from Orcombe Point at Exmouth to Old Harry Rocks at Studland, roughly ninety-five miles of cliff…

Three planning authorities across the Poole service area
Spaced along the slope, they read as part of the roof rather than additions.
Guide

Three planning authorities across the Poole service area

Draw thirty miles around Poole and you cross a unitary boundary, a county boundary and a national park. Three local…

What a conservation rooflight actually is: flush, slim, black, barred
Recessed so the glass sits close to the plane of the slate.
Guide

What a conservation rooflight actually is: flush, slim, black, barred

Ask four suppliers what makes a rooflight a conservation rooflight and you will get four answers, all of them partly…

Writing a rooflight into a listed building application
On a listed or conservation-area roof, the profile is the whole argument.
Guide

Writing a rooflight into a listed building application

An application for listed building consent is a document, and it is judged as one. Two identical rooflights on two…

flat-roof-rooflight-installation

12 guides
Broadstone and Creekmoor roofs where standard specification is right
The frame-to-membrane junction, which is where flat roofs are won or lost.
Guide

Broadstone and Creekmoor roofs where standard specification is right

Standard specification is the right answer here, and we will say so Most of this site argues that a flat…

Drainage falls that move water past a rooflight instead of round it
A flat unit lights the floor beneath it rather than the far wall.
Guide

Drainage falls that move water past a rooflight instead of round it

What a kerb does to water that was minding its own business Before the rooflight went in, rain landed on…

Fixed, hinged and pop-up units on a low pitch deck
The membrane is dressed up the kerb face and the fall carries water past it.
Guide

Fixed, hinged and pop-up units on a low pitch deck

Start with whether it needs to open at all On a pitched roof the answer is usually yes, because a…

Insulation depth at the kerb and the cold line you cannot see
Two smaller units often beat one large pane on a domestic deck span.
Guide

Insulation depth at the kerb and the cold line you cannot see

The drip that is not a leak A fair number of the calls we take about a flat roof rooflight…

Laminated inner pane, toughened outer, and where each belongs
Ponding beside a kerb. A flat roof is never flat, and this is what a lost fall looks like.
Guide

Laminated inner pane, toughened outer, and where each belongs

Two entirely different kinds of broken Glass over your head can fail in two ways, and the difference between them…

Post-war estate flat roofs in Poole and the spans they allow
The kerb is measured before anything is ordered.
Guide

Post-war estate flat roofs in Poole and the spans they allow

The question underneath “how big can it be?” Almost every conversation about a flat roof rooflight arrives at size within…

Reveal design: splayed, square and what each does to the light
A prepared kerb, squared and weatherproofed, before the unit goes on.
Guide

Reveal design: splayed, square and what each does to the light

Two rooms, the same rooflight, different light Fit identical units into two identical extensions and finish the opening differently inside,…

Setting out a rooflight so the plasterboard reveal lines up
The frame-to-membrane junction, which is where flat roofs are won or lost.
Guide

Setting out a rooflight so the plasterboard reveal lines up

One rooflight, set out three times, by three different trades A flat roof rooflight gets positioned at least three times…

Single ply, felt and GRP: how each one turns up the upstand
A flat unit lights the floor beneath it rather than the far wall.
Guide

Single ply, felt and GRP: how each one turns up the upstand

The question nobody asks until the roofer has gone On most flat roof rooflight jobs there are two trades and…

Timber upstand or proprietary kerb: what each does to the detail
The membrane is dressed up the kerb face and the fall carries water past it.
Guide

Timber upstand or proprietary kerb: what each does to the detail

Two words for the same job, and they are not the same thing Every flat roof rooflight sits on something.…

Why a flat roof rooflight is never actually flat
Two smaller units often beat one large pane on a domestic deck span.
Guide

Why a flat roof rooflight is never actually flat

“Flat” is a product category, not a geometry The thing the brochures do not put on the front page A…

Wind uplift at the harbour mouth and the fixings that answer it
Ponding beside a kerb. A flat roof is never flat, and this is what a lost fall looks like.
Guide

Wind uplift at the harbour mouth and the fixings that answer it

The harbour mouth is a different roof from the rest of Poole Between Sandbanks and Studland the water is roughly…

electric-rooflight-installation

12 guides
Cable routing through a warm deck without breaching the vapour layer
A chain actuator suits a light sash; a spindle drive suits a heavy one.
Guide

Cable routing through a warm deck without breaching the vapour layer

The electrical side of getting power to an actuator is a settled matter, and it is set out on wiring…

Chain actuators or spindle drives: which suits which opening
Left open on a still evening to purge the day's heat.
Guide

Chain actuators or spindle drives: which suits which opening

Two families of drive open almost every electric rooflight fitted in a house around Poole. Which one you end up…

Control options: wall switch, remote, app and hard wired scene
Open, it vents the hottest air in the room, which sits at the ceiling.
Guide

Control options: wall switch, remote, app and hard wired scene

Almost every conversation about controlling an opening rooflight starts with the app and ends up somewhere else. The useful way…

How a rain sensor decides to close, and when it gets that wrong
An open sash on an exposed roof is a sail. That is what wind sensors answer.
Guide

How a rain sensor decides to close, and when it gets that wrong

A rain sensor is not a weather forecast. It is a pair of conductive tracks, a threshold and a timer,…

Maintenance access for an actuator once the ceiling is closed up
The rain sensor closes it whether or not anyone is home.
Guide

Maintenance access for an actuator once the ceiling is closed up

An opening rooflight has one moving assembly and it is the only part of the installation certain to need attention.…

Opening angle, free area and the ventilation a unit really gives
The kerb is measured before anything is ordered.
Guide

Opening angle, free area and the ventilation a unit really gives

Two rooflights of exactly the same size can differ by a factor of three in how much air they move,…

Salt air on an actuator: sealing, gaskets and Sandbanks exposure
A prepared kerb, squared and weatherproofed, before the unit goes on.
Guide

Salt air on an actuator: sealing, gaskets and Sandbanks exposure

On a coastal roof an opening rooflight does not fail at the glass. It fails at the hinge knuckle, the…

Smoke vent rooflights, AOV controls and the standards behind them
A chain actuator suits a light sash; a spindle drive suits a heavy one.
Guide

Smoke vent rooflights, AOV controls and the standards behind them

An automatic opening vent and an electric rooflight look similar from the room below and are completely different products in…

What a vent does when the mains fails and the battery is flat
Left open on a still evening to purge the day's heat.
Guide

What a vent does when the mains fails and the battery is flat

A mains-fed electric rooflight with no supply does not close, does not sense rain and does not report a fault.…

When a fixed rooflight can take a motor and when it cannot
Open, it vents the hottest air in the room, which sits at the ceiling.
Guide

When a fixed rooflight can take a motor and when it cannot

People ask this in two different ways. “Can you put a motor on mine?” is a question about one specific…

Wind sensors on the harbour front where gusts arrive unannounced
An open sash on an exposed roof is a sail. That is what wind sensors answer.
Guide

Wind sensors on the harbour front where gusts arrive unannounced

Rain sensors get all the attention because wet carpet is visible. Wind does the expensive damage, and it does it…

Wiring a rooflight actuator back to a fused spur
The rain sensor closes it whether or not anyone is home.
Guide

Wiring a rooflight actuator back to a fused spur

Between your consumer unit and a rooflight sash there are five or six links, each of which can be done…

velux-window-installation

12 guides
Canford Cliffs pine debris and the VELUX drainage channel it blocks
A blind in the recess does more for July than the glass specification does.
Guide

Canford Cliffs pine debris and the VELUX drainage channel it blocks

Under a mature pine canopy a roof window is not dealing with autumn. It is dealing with a continuous, year-round…

EDW, EDL and EDJ flashings matched to the roof covering
From outside, the unit sits in the plane of the tiles.
Guide

EDW, EDL and EDJ flashings matched to the roof covering

A roof window almost never leaks through the window. It leaks at the junction between the window and the roof,…

GGL, GGU, GPL and GPU: the difference the middle letter makes
A loft room with the sash open on its catch.
Guide

GGL, GGU, GPL and GPU: the difference the middle letter makes

Two letters do almost all the work in a VELUX type code. The middle one says how the window opens;…

Insulation collars, vapour collars and the order they go in
Two smaller sashes give cross-light where one large one gives glare.
Guide

Insulation collars, vapour collars and the order they go in

Three separate collars go round a roof window frame. They do three different jobs, they sit in a fixed order…

Matching a new VELUX to an old one when the code has been dropped
The centre pivot is what lets the outer face be cleaned from inside.
Guide

Matching a new VELUX to an old one when the code has been dropped

Most old size codes are still made. A minority are not, and when you are holding one of those the…

Reading a VELUX size code: what CK04 and MK08 actually mean
The kerb is measured before anything is ordered.
Guide

Reading a VELUX size code: what CK04 and MK08 actually mean

A VELUX size code is not a model number. It is two measurements written as four characters, and once you…

Recessed installation with BDX and what it does to the reveal
A prepared kerb, squared and weatherproofed, before the unit goes on.
Guide

Recessed installation with BDX and what it does to the reveal

Recessing drops the whole unit lower into the roof build-up, so the glass sits closer to the plane of the…

Replacing a VELUX without disturbing the surrounding tiles
A blind in the recess does more for July than the glass specification does.
Guide

Replacing a VELUX without disturbing the surrounding tiles

The window is the easy part. The question that decides how a VELUX replacement goes is whether the tiles around…

Salt on the harbour side and what it does to VELUX flashing zinc
From outside, the unit sits in the plane of the tiles.
Guide

Salt on the harbour side and what it does to VELUX flashing zinc

On a coastal roof the flashing outlives its warranty or it does not, and the difference is metallurgy rather than…

Servicing a VELUX: hinges, filters and the sash that will not stay up
A loft room with the sash open on its catch.
Guide

Servicing a VELUX: hinges, filters and the sash that will not stay up

A roof window has four moving parts and three consumable ones. Almost everything that goes wrong with one is on…

The 180 degree pivot, the cleaning position and safe reach
Two smaller sashes give cross-light where one large one gives glare.
Guide

The 180 degree pivot, the cleaning position and safe reach

A centre-pivot roof window rotates the full half-turn so the outer face comes inside the room. That single piece of…

VELUX age plates and dating a unit already on the roof
The centre pivot is what lets the outer face be cleaned from inside.
Guide

VELUX age plates and dating a unit already on the roof

Age decides more about a roof window than condition does. A tidy-looking unit from a discontinued generation may have no…

replacing-a-failed-or-misted-rooflight

12 guides
Changing the glass without changing the frame, and when that works
Chalked coating on a marine-exposed frame: the coating failed before the glass did.
Guide

Changing the glass without changing the frame, and when that works

Whether you can change the glass and keep the frame comes down to one thing: how the frame holds the…

Frame corrosion, gasket shrinkage and the leak that follows
A new unit in a sound frame: clear glass, same opening, no roof work.
Guide

Frame corrosion, gasket shrinkage and the leak that follows

The glass gets the blame because it is the part you can see. In a good many of the failures…

Like for like replacement when the original size is no longer made
Often the unit changes and the frame stays, which is the cheaper honest answer.
Guide

Like for like replacement when the original size is no longer made

Somewhere on most 1990s extensions in Poole there is a rooflight that cannot be bought any more. Not a rare…

Matching a new unit to an existing kerb without rebuilding it
The perimeter seal is the part that ages, and it fails from the edge inward.
Guide

Matching a new unit to an existing kerb without rebuilding it

Assume the upstand is sound. Assume it has been sounded all round, the deck under it is dry and nobody…

Old Town and Quay replacements where access is the hard part
Misting sits between the panes, which is why cleaning never touches it.
Guide

Old Town and Quay replacements where access is the hard part

Between Poole Quay and the High Street there are roofs where the rooflight itself is the simplest thing about the…

Polycarbonate domes on Poole estate extensions after fifteen summers
The kerb is measured before anything is ordered.
Guide

Polycarbonate domes on Poole estate extensions after fifteen summers

A polycarbonate dome does not fail the way a sealed glass unit fails. Nothing mists, because there is usually nothing…

Reading a failed unit: what the pattern of misting tells you
A prepared kerb, squared and weatherproofed, before the unit goes on.
Guide

Reading a failed unit: what the pattern of misting tells you

A failed sealed unit is not a blank statement. The way the misting sits on the glass, where it starts,…

Removing an old dome rooflight and closing the kerb it leaves
Chalked coating on a marine-exposed frame: the coating failed before the glass did.
Guide

Removing an old dome rooflight and closing the kerb it leaves

A dome is usually the easiest thing on a roof to take off and the most awkward thing to leave…

Salt off the harbour and UV: what ages a rooflight seal fastest
A new unit in a sound frame: clear glass, same opening, no roof work.
Guide

Salt off the harbour and UV: what ages a rooflight seal fastest

Four things age a rooflight seal, and they are not equally guilty. Ultraviolet does the most damage to the sealant…

Twenty year old units and the moment replacement beats repair
Often the unit changes and the frame stays, which is the cheaper honest answer.
Guide

Twenty year old units and the moment replacement beats repair

A rooflight does not have an expiry date printed on it, and a firm that tells you twenty years is…

What a replacement day looks like from scaffold to making good
The perimeter seal is the part that ages, and it fails from the edge inward.
Guide

What a replacement day looks like from scaffold to making good

By the time we arrive to fit, the interesting decisions have all been made. The survey settled the kerb, the…

Why a sealed unit mists: the desiccant, the seal and the pressure cycle
Misting sits between the panes, which is why cleaning never touches it.
Guide

Why a sealed unit mists: the desiccant, the seal and the pressure cycle

A sealed unit does not mist because the glass has worn out. Glass does not wear out. It mists because…

roof-lantern-installation

12 guides
Getting a large lantern onto a roof when access runs through the house
The same lantern after dark, seen from the garden.
Guide

Getting a large lantern onto a roof when access runs through the house

The largest single piece decides the whole job A roof lantern arrives in parts, and almost all of them are…

Hip ends against gable ends: what each asks of the roof below
The pitch throws daylight sideways, lighting the back wall rather than only the worktop.
Guide

Hip ends against gable ends: what each asks of the roof below

Only the two ends are ever really in question A roof lantern has four sides and two of them are…

How glazing bars shed water into the kerb without wicking back
The kerb is squared and weatherproofed before the lantern is set.
Guide

How glazing bars shed water into the kerb without wicking back

A roof lantern is not sealed. It is drained. This is the single idea that makes everything else about glazing…

Kerb height, falls and keeping lantern glass clear of standing water
Ridge bar and glazing bars: where a lantern either sheds water or holds it.
Guide

Kerb height, falls and keeping lantern glass clear of standing water

The kerb does three jobs, and only one of them is holding the lantern up A roof lantern does not…

Parkstone villa extensions and the lantern proportions that suit them
The frame goes on square to the kerb, or nothing above it sits right.
Guide

Parkstone villa extensions and the lantern proportions that suit them

Why this particular house argues about proportion Parkstone is not a single kind of street, but a great deal of…

Part F ventilation in a lantern and the trickle vent argument
The kerb is measured before anything is ordered.
Guide

Part F ventilation in a lantern and the trickle vent argument

What Part F is actually asking for Part F of the Building Regulations covers ventilation, and Approved Document F is…

Powder coat grades on the Sandbanks spit and why standard finishes chalk
A prepared kerb, squared and weatherproofed, before the unit goes on.
Guide

Powder coat grades on the Sandbanks spit and why standard finishes chalk

Run a finger down the frame If there is a fine pale powder on your fingertip afterwards, and the frame…

Rafter depth decides the span a lantern can hold
The same lantern after dark, seen from the garden.
Guide

Rafter depth decides the span a lantern can hold

The question behind nearly every lantern drawing Somewhere in most conversations about a roof lantern, someone asks whether we can…

Ridge bar cold bridging and the drip you keep wiping off the sill
The pitch throws daylight sideways, lighting the back wall rather than only the worktop.
Guide

Ridge bar cold bridging and the drip you keep wiping off the sill

You have been wiping the same 200mm of sill since October It is always the same spot. One end of…

Sizing a lantern to the room under it, not to the roof opening
The kerb is squared and weatherproofed before the lantern is set.
Guide

Sizing a lantern to the room under it, not to the roof opening

The opening is a constraint, not a brief Almost every roof lantern enquiry arrives the same way. Someone has measured…

Structural openings: trimmers, lintels and the load a lantern adds
Ridge bar and glazing bars: where a lantern either sheds water or holds it.
Guide

Structural openings: trimmers, lintels and the load a lantern adds

A lantern is a load standing on a hole you just cut Every other decision about a roof lantern is…

Why a lantern gathers more summer heat than a flat rooflight
The frame goes on square to the kerb, or nothing above it sits right.
Guide

Why a lantern gathers more summer heat than a flat rooflight

The hole is not the glass Start with the arithmetic, because it settles most of the argument before any talk…

What these guides are for

These are the pages we would otherwise be reading out on the phone. Each one takes a single piece of rooflight or skylight detail — kerb height, rafter depth, flashing kits, U-values, actuator types, tunnel reflectivity — and explains what it does, what goes wrong when it is got wrong, and how to tell which applies to your roof.

They are written for the person in the middle of a project: the extension is going up, the loft is being converted, or a unit has failed and the decision is repair against replace. None of them are sales pages. Several of them will talk you out of the more expensive option.

Twelve guides behind each of the ten services

Every service hub carries its own set. If you know which item you are dealing with, start with its service page and work down into the guides beneath it.

Guide set What the twelve cover
Roof lanterns Kerb height and falls, rafter depth against span, ridge-bar cold bridging, getting a large frame through a house, powder coat grades on the spit, sizing to the room rather than the opening
Flat roof rooflights Timber upstand against proprietary kerb, how felt, GRP and single ply turn up the kerb, why a flat unit is never actually flat, wind uplift at the harbour mouth, drainage falls, reveal design
Roof windows Setting a window between rafters without cutting structure, trimming for a wider unit, flashing kits for plain tile, pantile and slate, head and sill height, and what each does to the view
VELUX windows Reading a size code, what GGL, GGU, GPL and GPU actually mean, matching EDW, EDL and EDJ flashings to the covering, recessed installation and what it does to the reveal
Electric and opening units Chain actuators against spindle drives, wiring back to a fused spur, how a rain sensor decides to close and when it gets that wrong, smoke vents and AOV controls
Energy efficiency What a U-value covers and what it quietly leaves out, g-value and solar gain, solar control coatings, warm edge spacers and the cold strip around the glass
Misted and failed units Why a sealed unit mists, like-for-like replacement when the original size is no longer made, changing glass without changing the frame, and when replacement beats repair
Walk-on glazing Structural build-up and how many laminated layers carry a person, point and distributed loads, anti-slip frit patterns, flush thresholds and drainage that does not pond
Conservation rooflights What makes a unit a conservation rooflight, Article 4 directions, listed building consent on a rear slope, and the roofs inside the Poole Old Town conservation area
Sun tunnels Rigid against flexible over distance, reflectivity and the light lost at every bend, routing through a loft full of services, diffuser choice and glare

Where a guide stops and a survey starts

What reading can settle, and what it cannot

A guide can settle: what a component does, which options exist, what the trade-offs are, roughly what Building Control will be looking at, and whether the thing you are worried about is normal or a defect. That is enough to walk into a quote conversation knowing what questions to ask.

A guide cannot settle: what your deck is built from, whether that joist will take the opening, whether the existing kerb is square, or what the covering has been doing under the flashing for the last decade. Those are measurements, and no amount of reading substitutes for someone on the roof with a tape.

So use the guides to decide what you want and to check what you are told. Use the survey to decide what is actually going to be built.

Where to start, by what stage you are at

  1. Still deciding whether to glaze the roof at all. Start at services and read the middle column. The item is usually decided by the roof you have, not by preference.
  2. Architect’s drawing in hand, wondering if it is buildable. Read the structural guides in the lantern and flat rooflight sets — spans, trimmers and kerb heights are where drawings and roofs most often disagree.
  3. Worried about summer heat or winter cold. The energy efficiency set, starting with the difference between U-value and g-value. Getting this wrong is the most common regret we hear about.
  4. Something has already failed. The misted and failed unit set, then the answers page on whether a misted unit is still weatherproof. Usually it is, and the urgency is lower than it feels.
  5. In a conservation area or a National Park. The conservation set first, before you price anything, because the profile and the position on the slope are decided there.

Written for Dorset roofs, not for a generic one

Roof coverings around here are not uniform, and the guides say so. Purbeck stone slate in Langton Matravers, natural slate through Wimborne, interlocking concrete tile across the post-war Poole estates, single ply and felt on the rear extensions of the 1990s, and heathland-edge bungalows in Broadstone with shallow decks that decide how tall a kerb can be. A flashing guide written for a national audience skips all of that, which is precisely where the leaks happen.

Guides, answers and costs do different jobs

Page type Best for Length and depth
Guides Understanding a component or a decision properly before you commit to it Long. Diagrams, tables and trade detail, with the exposure implications named
Answers One specific question you want settled now — “do roof lanterns leak”, “can a sun tunnel go round a corner” Short. Direct answer first, then the reasoning and the exception
Costs Working out what will drive your figure up or down before you get a quote One page on the five things that move a price. We publish no price list, and the page explains why

If a guide leaves you with a question it did not answer, ring 01202 923272 or send it through the contact page. Questions that come up more than twice get written up and added here.

Get a fixed quote

Tell us which way your roof faces.

We will come back with a specification, not a catalogue page. If your extension faces south we will tell you the G-value we would fit and why.

  • No pressure, no doorstep sales call
  • We handle the Building Control notification
  • 10-year workmanship guarantee on every installation
  • Installations and replacements across Poole and south Dorset

Prefer to talk it through? 01202 923272