How glazing bars shed water into the kerb without wicking back
The two-stage drainage inside a lantern glazing bar, why pressure equalisation beats sealing, and the six things that block the route between the glass and the kerb.
A roof lantern is not sealed. It is drained.
This is the single idea that makes everything else about glazing bars make sense, and it is the opposite of what most people assume. Nobody builds a lantern by trying to make every joint watertight. It is built on the expectation that a small amount of water will get past the outer line, and on giving that water a designed route back out.
Look at a glazing bar in section and you see why. There is an outer gasket or capping taking the weather. Behind it there is a chamber running the full length of the bar, with a fall down the slope. At the bottom, where the bar lands on the ring beam above the kerb, there is an outlet. Water that gets past the first line lands in the chamber, runs down it, and leaves at the bottom onto the flashing — outside the building, above the roof surface.
That is the whole system. Two lines of defence, one of them a drain rather than a seal. It is used on curtain walling, on windows and on every decent rooflight, and it works reliably for decades when nothing interferes with it. The failures are almost never a failure of the principle. They are something blocking, bridging or short-circuiting the route.
The journey, stage by stage
| Stage | Where the water is | What keeps it moving | What defeats it |
|---|---|---|---|
| 1. On the glass | The outer face of the pane | The pitch of the slope — gravity does all of it | A pitch so shallow that surface tension holds drops in place to dry and stain |
| 2. At the gasket line | The junction between pane edge and bar capping | Even gasket compression, shedding the bulk of it back onto the glass | Perished or relaxed gaskets, uneven compression from a deflecting bar |
| 3. In the drainage chamber | The void inside the bar, below the glass line | A continuous fall down the slope to the outlet | Debris, a setting block sat across the channel, or a low point from bar deflection |
| 4. At the bar foot | The junction of bar, ring beam and kerb | An end cap or drainage slot discharging onto the flashing | Sealant applied over the outlet by a well-meaning previous repair |
| 5. Onto the roof | The kerb flashing and the roof covering | Kerb height and the fall of the roof below | Discharging below the standing water line — a separate subject with its own page |
Stages one to four are what this page is about. Stage five is the kerb’s problem, and it is covered in kerb height, falls and standing water.
Pressure equalisation: why a small hole beats a big seal
The bit that sounds wrong is that the drainage chamber is deliberately open to outside air. Not open to rain — open to pressure. There are small vents alongside the drainage outlets whose only job is to let the air inside the chamber sit at the same pressure as the air outside it.
The reason is that rain on its own barely penetrates anything. What drives water through a joint is a pressure difference across it: wind pushing on the outside face while the inside stays still. That difference is a pump, and it will push water uphill, sideways, and through gaps that would otherwise shed it perfectly.
Equalise the pressure and the pump stops. Water that gets into the chamber then has nothing pushing it further, so it does the only thing left available and runs downhill to the outlet. This is why a bar with a few small, correctly placed holes performs better in driving rain than a bar someone has sealed solid — and why the instinct to run a bead of silicone along everything makes a lantern worse rather than better.
Capillary action is the actual enemy
Water goes uphill, and it does not need wind to do it
Hold two sheets of glass close together with their edges in a saucer of water and the water climbs between them. The narrower the gap, the higher it climbs. That is capillary action, and it is why a gap in a glazing assembly is dangerous at exactly one size: too narrow to drain, too wide to be a seal.
The design answer is never to make gaps smaller. It is to interrupt them. An anti-capillary groove — a deliberate widening cut into the profile — breaks the continuous narrow path, because water climbing the gap reaches the groove, the gap suddenly becomes too wide to climb, and it drops. Drip breaks on the underside of a capping do the same job by giving water a clean edge to leave from instead of a surface to run back along.
The exception worth knowing: this is also the reason a repair that tightens a joint can cause the leak it was meant to fix. Squeeze a draining gap down to a wicking gap and you have converted a drain into a straw.

Where the bar meets the kerb
Everything above concentrates at one point: the foot of each bar, where the drainage chamber has to discharge. It is the most detailed 100mm of the whole skylight and it is hidden under a capping, which is why it is also the least inspected.
Three things have to be true there. The chamber must be open, so water can leave. The discharge must land on the outside face of the flashing, not behind it, or the drainage system is quietly emptying into the roof build-up. And the outlet has to sit above the highest level water reaches on the roof surface, because an outlet below the water line is not an outlet, it is an inlet whenever the roof is wet.
How hard that detail is worked varies across Poole more than most people expect. Driving rain is rain plus wind, and it is the wind half that changes here. A lantern on the Sandbanks spit or at the harbour mouth faces a south-westerly with no fetch break and no upwind roughness, so the pressure differences across its gaskets are larger, more sustained and more often paired with salt. A lantern in Old Town, a few hundred metres away but with the town behind it, spends most of the winter in a genuinely sheltered position. Same product, same principle, very different demand on the same two lines of defence — which is why the gasket grade and the discharge detail are specified per zone rather than once for the whole town.
Six ways the drainage gets defeated
| Cause | How it shows itself | What it usually needs |
|---|---|---|
| Sealant over the outlets | Leak starts after a previous “repair”, not before it | Removing the sealant and reopening the drainage path |
| Debris in the chamber | Gradual onset, worse after autumn, worse on wooded plots | Clearing the channel and the outlets; then a maintenance habit |
| Setting blocks across the channel | Present from day one, on one pane only | Lifting the pane and repositioning the blocks clear of the drain |
| Perished or relaxed gaskets | Age-related, several bars at once, worse in wind-driven rain | Gasket replacement in the affected runs |
| Bar deflection creating a low point | Water emerging partway down a bar rather than at its foot | A structural look at span and section, not a sealing repair |
| Discharge behind the flashing | No visible water on the roof, damp appearing in the ceiling below the kerb | Reworking the bar foot and flashing relationship |
Five of those six are repairs to a lantern that is fundamentally sound. Only one of them — the deflection case — points at the frame being wrong for its span, and it is the one people reach for last when it should be checked early.
Setting blocks, end caps, and things fitted in the wrong order
Setting blocks are the small load-bearing packers a pane sits on. They are there to carry the glass and to keep its edge off the metal, and their position is specified — typically at quarter points along the supported edge rather than at the corners. Put one in the middle of a drainage channel and you have built a dam inside the bar on the day of installation. The lantern will be perfect for a year and then start weeping at the foot of one bar for no apparent reason.
End caps are the other one. They close the bottom of each bar and direct the discharge, and on most systems they are handed, sized and specific to the profile. A missing cap leaves the chamber open to wind-blown rain from below. A generic cap fitted because the right one was not on site changes where the water lands. Neither is visible from the ground and neither is visible from inside.
Both are assembly discipline rather than product quality. A well-made lantern installed carelessly will leak sooner than a mid-range one installed properly, and the difference is entirely in things nobody can see once the cappings are on. That is the honest argument for watching who fits a rooflight as closely as you watch which one you buy.

The five minutes that prevent most of this
- Look at the foot of every bar twice a year. Late autumn after leaf fall, and early spring. That is the whole maintenance regime for the drainage system.
- Clear, do not poke. Debris comes out with a soft brush or a rinse. A screwdriver into a drainage slot damages the profile and sometimes the gasket seating.
- Rinse from the top down. A hose run gently over the slopes flushes the chamber the way rain does. Watch where it emerges; that tells you the outlets are working.
- Check the flashing line while you are there. Water should be landing on the outside of the flashing and running away from the kerb, not disappearing behind it.
- Never seal anything you do not understand. If a hole looks like it should not be there, it is almost certainly a pressure equalisation vent doing its job.
- On wooded plots, do it three times. Pine drops needles continuously rather than in one autumn flush, and needles mat in a drainage channel far more effectively than leaves do.
If yours has already started
Water appearing inside a lantern is worth watching before anybody quotes for it. Note whether it comes with rain or with cold mornings, because a winter-only drip with no rain behind it is condensation rather than drainage, and that has its own causes and its own page. Note whether it emerges at the foot of a bar or partway up. Note whether it is one bar or all of them, and whether it started after somebody did work up there.
Those four observations usually name the cause before anyone gets on the roof, and they are the difference between a morning’s work reopening a drainage path and a quotation to replace a skylight that never needed replacing.
What we will and will not say
What we put in writing is a ten-year workmanship guarantee — a workmanship guarantee, not insurance backed, said plainly — and a fixed price after the roof has been surveyed rather than estimated from photographs. We will also tell you when a lantern does not need replacing, which is more often than the trade generally admits.
To have a drainage detail looked at, ring 01202 923272 and describe when the water appears rather than where. The service hub is at roof lantern installation.
Related reading
Can a roof lantern be fitted in winter?
Yes. Winter changes how the working day is organised, not whether a roof lantern can be installed. Cold is a…
Can a roof lantern be made to open?
Yes, but it is decided at order, not afterwards A roof lantern can be made to open. Most systems offer…
Can a roof lantern go on a pitched roof?
Not onto the slope itself. A roof lantern is designed to stand on a level kerb, and a pitched roof…
Can a roof lantern go over a garage conversion?
Frequently yes — but the garage decides, not the lantern Garage conversions are one of the better places to put…
Can a roof lantern sit on a flat roof without a kerb?
No. A roof lantern has to stand on an upstand of some kind — either a kerb built on site…
Can one cracked pane in a roof lantern be replaced on its own?
Normally yes, and that is a designed-in advantage of the format A roof lantern is assembled from a frame, a…