How a rigid sun tunnel out-performs a flexible one over distance

What a corrugated tube wall does to light, why the gap between rigid and flexible widens with every metre of run, and the point at which neither is the right product for the room.

A sun tunnel run from dome to diffuserLight enters at the dome and is reflected down the tube to a ceiling diffuser. Every bend costs reflectance, so a straight short run delivers far more than a long one with turns. Light falls with the square of the diameter.daylightdomeevery bend costs lightceiling diffuser

Over a short, straight drop between a roof plane and the ceiling below it, a flexible sun tunnel and a rigid one deliver light most people could not tell apart. Over three metres with a bend in it, they are not the same product at all.

The service page states the position in a sentence: rigid holds its light over distance. This is the working version of why. What a corrugated wall actually does to a beam, where flexible tube genuinely earns its place, how installation quality moves the answer, and the point at which neither tube is right and the room wants a rooflight instead.

Two different products sharing one name

Sun tunnel, sun pipe, light tube, tubular skylight. The words get used interchangeably for two constructions that behave differently.

A rigid tunnel is built from lengths of hard tube with a highly reflective inner surface, pushed together at sleeved joints and turned, where it has to turn, by purpose-made elbows. It arrives as a kit of parts and gets assembled in the loft in a particular order. A flexible tunnel is a spiral-wound concertina, reflective film over a wire helix, that comes out of the box as a compressed accordion and stretches to whatever length the run needs. It bends by hand, anywhere along its length, to any angle you like.

That last sentence is the appeal of flexible tube and also the problem with it. A product that bends anywhere gets bent anywhere, including places nobody planned and nobody will see again.

What a corrugation does to a beam of light

Light travels down a tunnel by bouncing. It enters at the dome, strikes the tube wall at a shallow angle, reflects, strikes again further down, and repeats that until it arrives at the diffuser. The wall is not a pipe carrying light the way a pipe carries water. It is a long series of mirrors, and every bounce is a transaction where a little energy is lost.

A rigid tube gives that bouncing beam a smooth, near-mirror surface. Light arriving at a shallow angle leaves at the same shallow angle, holding its direction, travelling on down the tube in long strides. Fewer bounces per metre, and each one keeps most of what arrived.

A corrugated wall is not smooth. Every ridge and every trough presents a surface tilted at a different angle to the one beside it. A beam hitting a ridge face does not carry on down the tube — it scatters. Some of it goes forward, some sideways into the opposite wall at a steeper angle than it arrived, and some of it goes back up the tube towards the dome it came from. Each of those redirections is another bounce, and every extra bounce is another chance to be absorbed rather than reflected.

The principle, and the number we will not give you

The principle: loss compounds. It is not one subtraction at the end of the run, it is a small fraction taken at every single bounce, multiplied together. A surface that returns a high proportion of what hits it and is struck ten times over a run behaves very differently from one struck forty times over the same distance.

What we will not do: quote you a percentage. Reflectance is a property of the specific tube, measured by the manufacturer under stated conditions, and it is published on their data sheet. Any figure an installer recites from memory over the phone is a guess wearing a decimal point. We will tell you which product we propose and where its declared figures are published, and you can read them yourself.

Rigid tube, and what it asks of the roof space

Rigid is the better performer, and it is also the fussier guest. It wants a route it can actually take. Elbows turn through a limited range — adjustable within a band, not free — so the path has to be worked out on paper before anything is cut, and there has to be enough clear space in the loft to swing a length of tube into position without fouling a purlin or a binder.

It also has to be assembled up there, in a confined space, by someone reaching over joists, with every joint taped so light does not leak out at the collars. A rigid run installed carelessly still beats a flexible one installed carelessly, but the margin narrows, and the margin is the entire reason for choosing it.

The other thing rigid tube asks for is honesty at survey. An obstruction found on fitting day with a van full of hard tube is an expensive discovery, which is why the route is walked and agreed before an order is placed.

Flexible tube, and what it is honestly good at

Flexible is not a cheap imitation. It solves a specific problem: a ceiling position that cannot move and a roof position that cannot move either, with something immovable between them.

Condition in the loft Rigid Flexible
Short, near-vertical drop under a metre Works well, marginal gain Perfectly adequate, easier to fit
Long run across a loft, three metres or more The only sensible choice Arrives dim and disappoints
Small offset around one joist or a cable tray Needs an elbow pair and space to swing them Absorbs the offset with no fittings
Congested trussed roof with webs at close centres Often cannot be threaded at all Threads through, at a cost in output
Tunnel that has to end in a specific ceiling spot Route planned to it, or the spot moves Reaches it, but check what the run cost you

Read the table as a decision about where the loss is acceptable, not about which product is better. A short flexible offset in an otherwise rigid run is a legitimate specification. A four-metre flexible snake across a loft because it was quicker than planning a route is not.

How a rigid sun tunnel out-performs a flexible one over distance
A landing that had no daylight of its own at all.

Distance is where the two separate

The reason this argument only gets heated about long runs is arithmetic. Over the first half-metre, both tubes deliver something bright, because nothing has had time to accumulate. The difference is a fraction of a fraction.

Extend the same two tubes to three or four metres and the bounce count goes up on both, but it goes up much faster on the corrugated one, and each of those extra bounces takes its cut. Two tunnels that looked comparable in a showroom are not comparable at the ceiling of a hallway at the far end of a Poole loft. This is also why a flexible run that seemed acceptable in June reads as gloomy in November, when there was less light entering the dome to spend in the first place.

As a working rule of thumb: under about a metre and a half, the tube type is rarely the thing that decides how the room feels. Beyond about three metres, it is close to the only thing. Between those, it depends on bends, diameter and what the dome can see. The manufacturer’s declared maximum run for the specific product is the governing figure in every case, and we work inside it rather than at it.

Sag, kink and the losses that appear on no specification sheet

A tunnel’s declared performance assumes it was installed the way the maker intended. Several common site habits quietly take light out of the room and none of them show up anywhere except in how the hallway feels.

  1. A flexible tube left with a belly in it. Not stretched taut, so the corrugations sit deep and close together instead of shallow and spread. More ridges per metre, more scattering, and a sag that collects nothing useful.
  2. A bend tighter than the product allows. The inner wall creases. A crease is a hard reflector pointing the wrong way, and it stays there for the life of the installation.
  3. Unsealed joints. Light escapes into the loft at every collar that was not taped, and warm moist air from the house gets in at the same points. That is the same defect appearing as two different complaints.
  4. Tube compressed to make a length fit. A flexible tunnel cut long and squashed to suit is a shorter tunnel with the corrugation density of a much worse one.
  5. Insulation packed against, and into, the run. Loft insulation heaped over a tube is fine. Loft insulation crushing a flexible tube out of round is not, and the two look identical from the hatch.

Under the pines, and out on the heath

Two Poole conditions that change the answer

Canford Cliffs and Branksome Park. Mature pine canopy over the roof means the dome starts with less light to spend before the tube takes its share. A long flexible run under evergreen shade is a deficit on a deficit, and the needles that settle on a small dome make it worse through the winter. In that setting the tube question sometimes turns out to be the wrong question entirely — read what pine debris does to a dome before choosing anything.

Broadstone, Creekmoor and Canford Heath. Post-war trussed roofs with diagonal webs at close centres. The void is wide but shallow and full of timber, which frequently rules a rigid route out on geometry alone. That house type has broadstone bungalows where the loft void is shallow and wide, because the decision there is made by the trusses rather than by the tube.

How a rigid sun tunnel out-performs a flexible one over distance
The roof end: a small dome that needs its own flashing like any other opening.

Checking a tunnel that is already in and disappointing

If you have an existing tunnel that never quite delivered, the tube type is worth establishing before anyone proposes replacing the whole thing. From the loft hatch with a torch you can usually see whether the run is hard tube or concertina, whether it is pulled straight or sagging, whether the bends look forced, and whether daylight is visibly escaping at the joints.

A dull tunnel is not always a dull tube. A dome under debris, a cloudy diffuser, or a tunnel aimed at the wrong part of the ceiling all produce the same complaint, and all are cheaper to fix than a re-run.

Where neither tube is the answer

The honest position, stated plainly

A sun tunnel is not a substitute for a rooflight where a rooflight would fit. If the room has a roof plane directly above it and the structure will take an opening, a rooflight will put more daylight into that room than any tunnel of any construction, and it will give a view of the sky as well. Tunnels exist for rooms that have no roof plane of their own — internal hallways, landings, en-suites, utilities, stairwells. That is the job.

So if you are weighing a long, awkward, bent tunnel to reach a back bedroom that has its own ceiling under its own rafters, we will say that the tunnel is the wrong product before we say which tube it should be made of. The comparison is set out at length in where a sun tunnel beats a rooflight.

What the survey settles, and what we write down

The tube decision is made in the loft with a tape measure, not on the phone. What gets established is the straight-line distance from the proposed roof position to the proposed ceiling position, every obstruction between them, how far either end can move to shorten the run, and what the dome will actually be able to see once the surrounding roof and trees are taken into account.

From that we specify the tube type, diameter, the number of turns and the product, and we name the exposure zone the roof sits in so the flashing and the dome material suit it. The quotation states all of that in writing along with a fixed price after survey, and the workmanship carries a ten-year guarantee, which is our own guarantee and is not insurance backed.

To get a route walked and a straight answer about whether a tunnel is even the right product for your room, ring 01202 923272.

Get a fixed quote

Get a fixed quote

Tell us which way your roof faces.

We will come back with a specification, not a catalogue page. If your extension faces south we will tell you the G-value we would fit and why.

  • No pressure, no doorstep sales call
  • We handle the Building Control notification
  • 10-year workmanship guarantee on every installation
  • Installations and replacements across Poole and south Dorset

Prefer to talk it through? 01202 923272