Single ply, felt and GRP: how each one turns up the upstand
The three flat roof coverings compared at the one joint that keeps the water out: the face of the rooflight upstand, its corners and its termination.
The question nobody asks until the roofer has gone
On most flat roof rooflight jobs there are two trades and one joint between them. Somebody waterproofs the roof, somebody glazes the opening, and the water is kept out by the place where those two pieces of work meet: the face of the upstand, where the covering is turned up and terminated.
Three materials do that job on the roofs around Poole Harbour, and they do it in genuinely different ways. Single ply is welded. Felt is bonded with heat. GRP is laminated wet and cures into one piece. None of them is inherently better at an upstand, but each one has a different weak point, a different season, a different corner detail and a different attitude to the kerb underneath it. A homeowner who has only ever been told “it’s a flat roof” is usually surprised how much of the skylight specification is really a decision about the covering.
Single ply: welded, and the corner is the examination
Single ply membranes — PVC, TPO and their relatives — arrive as sheet and are joined by hot air welding, which fuses the two layers into one material rather than sticking them together. Up a rooflight upstand, the sheet is dressed from the deck, over the corner of the sole plate, up the face, and terminated at the top.
The flat runs are straightforward. The four corners are the whole test, because a sheet cannot turn an internal corner without either folding or being cut, and the answer is a pre-formed corner piece welded in, or a hand-welded gusset made on site by someone who does it often. A folded corner that has merely been pressed into place is the single most common single ply defect we find around an existing rooflight, and it usually shows first as a stain on the ceiling directly beneath one corner rather than as a general damp patch.
The advantages are real: single ply is light, it copes with movement, it can be welded in cold weather when other systems cannot, and a repair is another weld rather than a patch of different material. It also bonds to compatible proprietary kerbs that are supplied with a welded flange, which removes the interface altogether.
Torch-on felt: layers, gussets and an open flame beside timber
A rule with a real exception
The rule: modern reinforced bitumen membrane is laid in two or three bonded layers, and at an upstand every layer is carried up the face, with reinforcing gussets at the internal corners and the top layer finishing the detail. A single layer flapped up the kerb is not a detail, it is a hope.
The exception that changes the method: a torch is an open flame, and a timber upstand is combustible, as is anything in the void behind it. Close to a timber kerb, good practice is to move off the flame — self-adhesive or cold-applied layers at the upstand, hot air rather than gas, or a torch-free zone around the detail entirely. Roofs have been lost hours after the roofer packed up, from heat that travelled into a cavity nobody could see.
What that means for your quote: if your roof is felt and your upstand is timber, the perimeter detail is not the same product as the field of the roof, and it should be named separately.
Where felt earns its keep is on repairs and on roofs that are already felt. It can be built into and onto existing bituminous work, patched by anybody, and it tolerates a slightly imperfect substrate better than a welded sheet does. What it dislikes is standing water at a detail and a substrate that moves, which is why the fall around the unit matters as much as the material choice.
GRP: one piece, once, and a weather window to do it in
Glass reinforced polyester is laid wet. Chopped strand mat is laid over a rigid deck and wetted out with catalysed resin, taken up the face of the upstand in the same operation, and dressed over a trim at the top. When it cures there are no joints at all — the upstand and the field are the same lamination, which is why GRP upstands rarely fail in the way a bonded one does.
The price of that is process. GRP wants a dry substrate, a workable temperature and a period without rain while it goes off, which on the Dorset coast in February is a real scheduling constraint rather than a technicality. It wants a rigid deck, because the cured laminate has little tolerance for a board that deflects underfoot. And it wants the right trims: the top edge of a GRP upstand is terminated in a proprietary trim rather than simply stopping, or the exposed edge becomes the thing that fails first.
It also dislikes being laminated directly onto certain plastics, which matters when a proprietary kerb is in play — resin does not key to everything, and the kerb manufacturer’s compatible detail is the one to follow rather than the one that is convenient on the day.

The three side by side at the upstand
| At the upstand | Single ply | Reinforced bitumen felt | GRP |
|---|---|---|---|
| How it is joined | Hot air welded — fused sheet | Heat or adhesive bonded, in layers | Laminated wet, cures as one piece |
| The corner detail | Pre-formed or hand-welded gusset | Reinforcing gusset under the cap layer | Continuous lamination, no corner joint |
| Weather it can be laid in | The widest window of the three | Dry, and not in a hard frost | The narrowest — dry, mild, no rain while curing |
| Repairing it later | Weld a patch, same material | Easiest of the three, any competent roofer | Grind back and re-laminate — a specialist job |
| With a proprietary kerb | Often a welded flange, best integration | Check heat compatibility with the kerb face | Check the resin will key to the kerb material |
| Where it fails first | A folded, unwelded corner | A single layer taken up the face, or a flame-shy top edge | An unterminated top edge, or a deck that flexes |
Termination: how the covering is held at the top
Whatever the material, it has to stop somewhere, and it has to stop in a way that stops water getting behind it rather than merely stopping. In practice that means a mechanical termination — a bar, a trim or a clamped edge — near the top of the upstand, with the rooflight frame then landing over it.
What we look for on an existing unit is simple enough to check yourself from a ladder, carefully, or from photographs: is the covering held at its top edge by something, or is it held by sealant alone? Sealant at a termination is a maintenance item pretending to be a detail. It has a life of years, not decades, and when it goes the water does not appear at the top of the kerb where the failure is. It appears at the lowest point of the ceiling, sometimes a metre away.
EPDM, liquid systems and the rest of the field
Two others turn up often enough to mention. EPDM rubber is a single sheet, bonded rather than welded, and at an upstand it relies on adhesives and pre-formed corners; laid well it is excellent and long-lived, and laid badly the corners lift. Liquid applied systems — polyurethane and similar — are painted on with reinforcing fleece, which makes them very good indeed at awkward geometry, and they are often the sensible answer where a rooflight upstand meets a wall, a pipe and a change of level within the same half metre.
What all five share is the same truth: the material in the middle of the roof is not what keeps you dry. The detail at the upstand is.

How each one ages across the Poole zones
Exposure does not treat these materials equally. On the spit at Sandbanks and Studland, the load is wind and driven salt with no fetch break, and the question is mechanical: can the termination and the perimeter hold against uplift, and is every fixing in it stainless of the right grade. Under the pine canopy at Canford Cliffs and Branksome Park the load is organic — needles, resin and leaf litter that gather along the upslope face of a kerb and hold moisture against a detail for months. There, a material that dislikes being permanently wet at a joint is a material that will need attention. Inland at Broadstone, Creekmoor and Canford Heath none of that applies, and any of the three systems laid properly will do the job without a coastal upgrade on the bill.
Who does what, and where the handover sits
- Opening formed and kerb built or set. Structure trimmed, upstand square and to height, and checked before anything waterproof arrives.
- The covering is dressed up the face. By whoever owns that system — and if that is a separate roofer, the sequence is agreed before the day rather than negotiated on the roof.
- The termination is made and inspected. Mechanically held, corners formed properly, and photographed, because within an hour it will be invisible under a frame.
- The unit is bedded and fixed. Onto the top of the kerb, over the termination, with the frame’s own drainage path clear.
- Tested with water, not with optimism. A hose test before making good inside, while a correction still costs an hour.
Where a roof already has a covering nearing the end of its life, we will say so rather than glaze into it. Fitting a new rooflight into a membrane with three years left is buying the same scaffold twice.
How much of this we can tell you before we see the roof is less than you would like. The covering can usually be identified from a photograph, but its age, the number of layers, the state of the corners and whether the upstand beneath it is sound are all survey questions. What we can say in advance is which of the three systems we would expect to specify on a given roof and why — and that whichever it is, the upstand detail will be described on the quote in words rather than implied by the word “flashing”.
To talk a flat rooflight or skylight through against the covering you actually have, ring 01202 923272. If the honest answer is that the roof needs a roofer before it needs glass, you will get that answer on the phone.
Related reading
Broadstone and Creekmoor roofs where standard specification is right
Standard specification is the right answer here, and we will say so Most of this site argues that a flat…
Can a flat rooflight be fitted from inside?
Effectively no — not the part that keeps water out. A flat roof rooflight is weathered by dressing the roof…
Can a flat rooflight be fitted to a shed or outbuilding roof?
Yes, and it is usually the simplest work we do Yes. A flat rooflight goes into a garage, workshop, garden…
Can a flat rooflight be retro-fitted to an existing flat roof?
Yes — retro-fitting into an existing flat roof is the majority of this work, not the exception. What decides whether…
Can I fit a flat rooflight to a felt roof?
Yes, and felt is one of the more forgiving coverings to detail Yes. A flat rooflight can be fitted to…
Can two flat rooflights be fitted side by side?
Yes, and it is a common arrangement — but the interesting part is not the two units, it is the…