1930s semis in Poole: rafter spacing and the window sizes it allows

How the interwar semi that built half of suburban Poole is framed, covered and set out, and what that allows in the way of a roof window.

A roof window set between rafters in a pitched coveringThe window sits in the plane of the covering between existing rafters. A flashing kit matched to the covering carries water around the frame, and the underlay is dressed to a collar so anything passing the tiles is returned to the outside.roof windowrafterrafterflashing kitcovering

Half of suburban Poole was built to one drawing

Between the wars the town spread outwards fast, and it spread in one shape: the bay-fronted semi-detached pair, two up two down with a back addition, a hipped or gabled roof and a chimney at each flank. Parkstone, Penn Hill, Lower Parkstone, Alder Road, the streets running up from Ashley Cross, chunks of Branksome and the older end of Broadstone are full of them. They are the single most common house we are asked to put daylight into.

That is useful, because a house type built repeatedly to a familiar pattern has a roof you can predict before you climb into it. Not guess at: predict, then verify. This guide is about what a 1930s roof in Poole is usually made of, what it will usually allow, and the four or five places where the prediction is wrong often enough to be worth checking every time.

What is over your head in a 1930s roof

It is a cut roof, built in place by a carpenter rather than delivered on a lorry. Common rafters run from wall plate to ridge board. Part way up the slope a purlin runs horizontally under them, and that purlin is held by struts leaning back onto a load-bearing internal wall, usually the one between the two bedrooms. Ceiling joists tie the feet of the rafters together, and the whole thing is made of dry, hard, rough-sawn softwood that will blunt a drill bit.

The useful consequence is that a common rafter in this kind of roof is not part of a designed triangulated frame. It carries its share of the covering between the wall plate and the purlin, and again between the purlin and the ridge, and that is all it does. Nothing you do to one member invalidates a calculation somebody else made in a factory. That is not permission to cut one, but it does mean a trimmed opening here is ordinary carpentry rather than an engineered special.

The purlin is the thing that decides the position, far more often than the rafters do. In a typical Poole semi it sits roughly halfway up the slope, around 1.2 to 1.6 metres above the ceiling joists, and it runs right across the bay you wanted. A window can go above it, below it, or be designed around it, and those are three different jobs. Find the purlin in the first five minutes of any loft visit and half the questions answer themselves.

Imperial setting out, metric windows

A carpenter in 1934 set the rafters out in inches. Nothing made today is sized in inches. The mismatch is small but it lands exactly where it hurts, and it explains why so many of these roofs are 20mm short of the obvious answer.

Original setting out In millimetres Typical clear gap What tends to happen
16 inch centres 406mm Around 355mm Nothing standard fits between. One rafter comes out or the daylight comes from a sun tunnel
18 inch centres 457mm Around 405mm The most common spacing in these houses, and the most disappointing. Still short of a standard width
20 inch centres 508mm Around 455mm Tantalising. Close enough that people try to force it, and it still does not go
24 inch centres 610mm Around 555mm The narrowest standard width drops straight in with nothing cut

Rafters themselves are usually 2 by 4 or 2 by 5 sawn, which comes out at about 47 to 50mm thick once you allow for how rough the sawing was. Depth of 100mm to 125mm is normal, which matters later because there is not much room in it for insulation at the perimeter. The spacing wanders too. Hand setting out over a 7 metre wall plate drifts, and it is common to find 18 inch centres for six bays and then one bay at 21 inches where the carpenter was correcting himself near the hip. That bay is worth finding. The detail of reading rafter spacing properly is covered in setting a roof window between rafters.

The covering, and whether it is the original one

Three coverings turn up on these roofs, and the third one changes the conversation.

Covering How to recognise it What it means for a new opening
Original clay plain tile Small, roughly 265 by 165mm, double lapped, often weathered to a soft orange Small units re-lay neatly round an opening. Brittle with age, so allow for breakages and find spares first
Original clay pantile or interlocking clay Single lap, an S curve or a shallow roll, one tile covering far more area The profile height governs the flashing family. A deep curve needs the deep-profile kit, not the plain one
Later concrete interlocking re-cover Heavy, grey or artificially coloured, often with a flat or bold roll face and a crisp modern edge Very common from the 1970s onwards. Heavier than what the roof was built for, and the battens underneath are usually the new ones

The re-covered roof is the one to look at twice

A great many Poole semis were stripped of clay and re-laid in concrete interlocking tile somewhere between 1970 and 1995. Concrete tile is substantially heavier per square metre than the clay plain tile the roof was framed for, and some of those re-covers went on without any strengthening at all. If the rafters have a visible sag between purlin and ridge, or the ridge line dips in the middle when you sight along it from the garden, that is worth understanding before an opening is cut in it, not after. It does not necessarily stop the job. It does change what we look at.

1930s semis in Poole: rafter spacing and the window sizes it allows
The kerb is measured before anything is ordered.

Hipped, gabled, and the slope you can actually use

Poole’s interwar semis come both ways. A gabled pair has two clean rectangular slopes and a brick gable wall at each end. A hipped pair, more common on the wider plots and the corner sites, has the main slopes cut back to a hip at each end, with short hip rafters running down to the corners.

On a hipped roof the usable area shrinks in the corners, and the bays near the hip are foreshortened, so the tall narrow unit that works so well on these roofs has to sit inboard. There is also less headroom for a room in the roof, which is why hipped semis so often end up with a hip-to-gable conversion. If that is on the horizon, the window position should be planned against the roof you are going to have, not the one you have now.

Aspect decides the rest. The front slope on most of these streets faces the road, the rear slope faces the garden. Homeowners almost always ask for a skylight on the rear, and that is usually the right answer: better privacy, better view, and on a street where the front elevations still read as a matching pair, a new opening on the back attracts no attention at all.

The back addition, which is a different roof

Almost every one of these houses has a two-storey or single-storey rear outrigger over the kitchen or the bathroom. Its roof is a separate structure and it rarely matches the main one. Expect a shallower pitch, lighter or shorter rafters, a lean-to arrangement abutting the main rear wall, and sometimes a flat or near-flat deck where a 1960s bathroom extension was added.

That last case is where the words change. A pitched slope takes a roof window kept dry by flashing interleaved with the tiles. A flat or very shallow deck takes a kerb-mounted rooflight kept dry by the membrane dressed up the upstand. They are different products with different failure modes, and the honest answer for a flat-roofed back addition is the second one.

The back addition is often the best daylight opportunity in the house and the last one anybody considers. It sits over the kitchen or the utility, it usually faces the garden, its roof is low enough to reach from a modest tower, and nobody can see it from the street. In a Penn Hill or Ashley Cross semi where the main loft is full of purlins and struts, the outrigger is frequently where the light actually comes from.

Where the party wall lands, and why the ridge matters

In a semi-detached pair the party wall normally rises through the roof space, sometimes to the underside of the slope and sometimes only to ceiling level in the older or cheaper builds. Either way, a window sited close to it brings two questions with it: the fire separation between the two lofts, and whether the work touches your neighbour’s half of the structure. Neither is an obstacle on a normal job and both are cheaper to raise at survey than at first fix. The detail sits on roof windows and the party wall.

The ridge matters for a plainer reason. These roofs are not tall, and the run from wall plate to ridge on a typical 40 to 45 degree slope is often only around 3 metres. Take out the courses that have to stay above the head of the window and the courses that have to stay below the sill, and the window has less room to move up and down the slope than people expect.

1930s semis in Poole: rafter spacing and the window sizes it allows
A prepared kerb, squared and weatherproofed, before the unit goes on.

What a 1930s semi realistically gives you

  1. Find the purlin and the struts. Measure their height above the ceiling and note which bays the struts land in. Those bays are out.
  2. Measure four consecutive bays at the height the window will sit, not at the eaves where the birdsmouth cut widens the apparent gap.
  3. Measure rafter depth. If it is 100mm, the perimeter insulation detail needs planning rather than assuming.
  4. Check the covering and find out whether there are spares in the garage, under the hedge, or stacked behind the shed. On a clay plain tile roof, twenty salvaged tiles are worth having.
  5. Sight the ridge from the garden. A dip in the middle of a concrete-tiled 1930s roof is information.
  6. Stand where you will stand in the finished room and decide the head height from there, because on a shallow-headroom loft that is what the whole job is for.

Work through that list and the shortlist writes itself. On an 18 inch roof it is a trimmed opening or a pair of nothing; on a 24 inch roof a tall narrow unit goes in with the structure untouched; on a re-covered roof there is one more conversation to have first.

What we put in writing

A survey on a house like this takes about an hour and settles the framing, the purlin position, the covering and whether it is original, the exposure, and the position that actually lights the room rather than the wall. Out of it comes a fixed written price, with the reason for every line on it named. Our work carries a ten-year workmanship guarantee, stated plainly as not insurance backed; the unit and the glass carry their own manufacturer warranties.

Whether you call it a roof window, a skylight or a rooflight, the 1930s roof over it has its own habits, and we would rather read them with you in the loft than over the phone. Ring 01202 923272.

Get a fixed quote

Get a fixed quote

Tell us which way your roof faces.

We will come back with a specification, not a catalogue page. If your extension faces south we will tell you the G-value we would fit and why.

  • No pressure, no doorstep sales call
  • We handle the Building Control notification
  • 10-year workmanship guarantee on every installation
  • Installations and replacements across Poole and south Dorset

Prefer to talk it through? 01202 923272