Argon and krypton fills matter less than the brochure suggests

What a gas fill contributes to a rooflight, why the cavity width matters as much as the gas in it, how long argon stays put, and the three components that deserve the budget ahead of it.

U-value and g-value pull in opposite directionsU-value measures heat leaving through the unit; g-value measures solar energy coming in. A coating that cuts summer gain also cuts the winter daylight and warmth a room receives, which is why the right answer depends on orientation and on what shades the roof.solar energy ing-valueheat outU-valueglazed unitlowering one usually raises the other

The cheapest line on the specification is usually the loudest

Argon fill appears on almost every glazing quotation in the country, frequently in bold, occasionally as a paid upgrade. It is a genuine improvement and it costs the manufacturer very little. Those two facts together explain its prominence far better than its contribution does.

This page is not an argument against argon. We specify it as standard and we would not leave it out. It is an argument about proportion: the gas is a modest, real gain that sits well below the coating, the spacer and the frame in the order of things that decide whether a skylight performs, and a quote that leads with the fill is often quiet about the three that matter more.

What the gas is doing in there

Heat crosses the cavity of a sealed unit by three routes, and the gas is only involved in two of them.

Route What it is What controls it
Radiation Heat radiated from the warm inner pane straight across to the cold outer one. On an uncoated unit this is the largest share The low-emissivity coating, and nothing else. The gas has no effect on it whatever
Convection A circulating loop of gas rising off the warm pane, crossing, cooling and returning Cavity width and gas density. This is where argon and krypton do their work
Conduction Heat passed directly through the still gas from molecule to molecule The gas itself. Argon conducts more slowly than air, krypton more slowly again

That first row is the reason the gas ranks below the coating. Strip the low-emissivity coat out of a unit and radiation dominates the cavity, and no fill you can buy compensates. Put the coating in and radiation collapses, at which point the gas is working on what is left. Useful, and second in order.

Cavity width has an optimum, and wider is not better

This is the part most often got wrong, including by people selling glazing. A wider cavity is not steadily better. Widen the gap and conduction falls, because the heat has further to travel through still gas — but past a certain width the gas has room to set up a proper convection loop, and the loop carries heat faster than conduction ever did. There is a peak, and beyond it performance turns back down.

Each gas has its own optimum, and denser gases peak at narrower gaps. That is the whole reason krypton exists as a glazing product: it performs best in a cavity too narrow for argon to be at its best, which makes it the answer for slim sightlines, for conservation-profile units and for triple glazing that has to fit an ordinary frame depth. It is also markedly more expensive, being a far rarer gas, and on a standard-depth domestic rooflight it buys very little that argon has not already bought.

What this means on a quote

A fill is only as good as the cavity it is in. Argon in a cavity far from its optimum performs worse than argon in a well-chosen one, and the gas name on the quote does not tell you which you have. The cavity width is part of the unit specification, so it can be asked for.

Krypton is a solution to a depth problem. If nothing about your frame constrains the cavity, the case for paying for krypton on a domestic skylight is thin. If the frame is slim by design — a conservation-profile unit on a visible Poole Old Town slope, for instance — it is doing something argon cannot.

Lying down, the cavity behaves worse

A convection loop needs a top and a bottom. In an upright window the cavity is narrow in the direction the loop would have to circulate, and the loop is largely suppressed. Lay the same unit near-horizontal and the geometry inverts: the warm pane is now underneath the cold one, the gas is free to rise across the full width of the pane rather than the width of the gap, and convection runs far more readily.

Two consequences follow, and they cut in opposite directions. The bad news is that a rooflight will not deliver the same real performance as the identical unit standing in a wall — which is why the compliance figure is declared in the vertical plane and why the number on the certificate is a convention rather than a prediction. The good news is that because convection matters more overhead, the fill that suppresses it is worth relatively more in a skylight than in a window. Argon earns a slightly larger share of its keep on a roof.

How the vertical-plane declaration works and what else it leaves out is set out in what a rooflight U-value covers.

Argon and krypton fills matter less than the brochure suggests
The result the specification is aiming at: even light, no hot patch.

How long it stays in

The fair question, and the one people are usually fobbed off on. Sealed units are filled to around ninety per cent argon at manufacture, and the European product standard permits a leakage rate of no more than one per cent of the fill a year. A unit made to that standard still holds the large majority of its gas after twenty years, and the performance drift over that period is small.

The useful part is what it tells you about a unit that does not hold its fill. Gas escapes through the edge seal. An edge seal poor enough to lose gas quickly is an edge seal that will later let moisture in, and moisture between the panes is visible. So the failure announces itself as misting long before you would notice it as a heating cost.

The practical version: you will see a failing unit before you feel it. Nobody has ever detected a slow argon loss from their heating bill, and nobody has ever missed a misted pane. If a rooflight in Poole or Dorset is clear, its fill is very probably intact, and if it has gone cloudy the fill is the least of what has gone wrong. That is a question for the misted rooflight pages.

Where the fill sits against everything else

Ranked by what actually moves the finished performance of a rooflight, from the top:

  1. The low-emissivity coating. The largest single move on heat loss and the cheapest performance in the unit. An uncoated air-filled double sits near 2.8 W/m²K at the centre pane; add a soft low-emissivity coat and an argon fill and a comparable build-up commonly lands somewhere around 1.1 to 1.2. Almost all of that step is the coating.
  2. The kerb and the junction. A ring of uninsulated timber round the opening can leak more than the glass it carries, and nothing on the glazing specification describes it.
  3. The frame’s thermal break. A cold metal path through the frame gives a wet perimeter line in January no matter what is in the cavity.
  4. The spacer and edge seal. A warm edge in a dual-sealed unit lifts the edge temperature and decides how long the whole thing lasts.
  5. The gas fill. Real, modest, and by this point working on what the four above have left.
  6. Krypton over argon. Worth it when the cavity is constrained by design. Otherwise a premium for a fraction of a fraction.

Those U-values are indicative of typical build-ups rather than a specification. The manufacturer’s declared whole-unit figure for the actual rooflight is what governs, and it is what we quote.

The two ways a fill claim goes wrong

The first is the upgrade that is not one. Argon has been standard on ordinary domestic glazing for many years. Presented as a chargeable extra it is a pricing decision rather than a specification decision, and it is worth asking what the alternative would have been.

The second is subtler and costs more. A quotation that is expansive about the gas and silent about the spacer, the frame break and the kerb detail is emphasising the item that is cheapest to supply. The gas cannot be inspected once the unit is made; the spacer can be named, the frame break can be described and the kerb detail can be drawn.

Three things you can check, and one you cannot

You cannot verify the fill. Not on delivery, not on the roof, not in ten years. You are taking it on the manufacturer’s declaration, which is reasonable — it is simply not a basis for choosing between two quotes.

You can verify the spacer by name, the frame’s thermal break by its section, and the kerb insulation by watching it go in. Those three decide far more of the outcome and every one of them leaves evidence.

Argon and krypton fills matter less than the brochure suggests
Shade stops heat outside the glass, where it is still cheap to stop.

Exposure, and why no roof here delivers the lab figure

A declared U-value assumes a standard external surface resistance — a still-ish film of air clinging to the outer pane, doing a small amount of insulating. Wind removes it. At Sandbanks, Studland and the harbour mouth the south-westerly arrives off open water with no fetch break, strips that film continuously, and holds the outer pane closer to air temperature than the calculation assumes. The cavity then works across a larger temperature difference than it was tested at.

The gas fill does not change under that treatment, and neither does the coating. What changes is that the whole unit runs harder, which raises the value of everything in it and raises the value of the edge seal most of all. Inland at Broadstone, Creekmoor, Canford Heath and Upton the air is comparatively still, the unit sits much closer to its declared figure, and ordinary specification is the right specification. Under the pine canopy at Canford Cliffs and Branksome Park the trees break the wind as well as the sun, so those roofs also run close to the lab figure — the trade-off there is daylight rather than heat.

What we specify, and where we would rather the money went

Argon as standard in a dual-sealed unit with a warm edge spacer, low-emissivity coating on surface 3, and a laminated inner pane because it is overhead glazing under Part K. Krypton only where the cavity is genuinely constrained — a slim conservation profile, or a triple unit that has to sit in an ordinary frame depth — and we will say plainly when it is not needed.

If a budget has to give somewhere, it does not give at the coating, the edge seal or the kerb. Those three decide whether you have a warm skylight in ten years. We will not quote a saving in pounds or a payback period for any of it: those depend on the house, the occupancy and the weather, and a figure invented to make a sale would be worth nothing to you afterwards.

Our installation work carries a ten-year workmanship guarantee — a workmanship guarantee, and not insurance backed. The price is fixed in writing after we have been on the roof. Ring 01202 923272 if you have a quotation in front of you that is enthusiastic about gas and quiet about everything else.

Get a fixed quote

Get a fixed quote

Tell us which way your roof faces.

We will come back with a specification, not a catalogue page. If your extension faces south we will tell you the G-value we would fit and why.

  • No pressure, no doorstep sales call
  • We handle the Building Control notification
  • 10-year workmanship guarantee on every installation
  • Installations and replacements across Poole and south Dorset

Prefer to talk it through? 01202 923272