1930s Poole semis with internal bathrooms and no wall to reach

How the roof structure of an interwar Poole semi shapes a tunnel route into a windowless inner bathroom, which obstructions repeat house after house, and where a rooflight is the better answer.

A sun tunnel run from dome to diffuserLight enters at the dome and is reflected down the tube to a ceiling diffuser. Every bend costs reflectance, so a straight short run delivers far more than a long one with turns. Light falls with the square of the diameter.daylightdomeevery bend costs lightceiling diffuser

The interwar semi built across Parkstone, Winton, Penn Hill and Oakdale has a recognisable problem: a bathroom in the middle of the first floor with no external wall, no window, and nothing above it but a loft. It is the single commonest reason anyone in Poole asks about a sun tunnel.

Because the house type repeats, so do the obstructions. This page is what that particular roof tends to contain, where the route usually goes, and the cases where the honest recommendation is a rooflight over the landing instead.

Why the bathroom ended up in the middle

These houses were planned around two good bedrooms at the front and back, each taking an external wall and a bay if there was one. The bathroom took what was left: a strip in the middle of the plan, over the hall or stair, often sharing a wall with an airing cupboard and reached off a small square landing.

Some have a small window into a side elevation. Many, particularly where the pair was built tight to the boundary or where a later extension enclosed the flank, do not. Others lost their window when a rear extension or a downstairs cloakroom reshuffled the plan in the 1980s.

The result is a room with artificial light on all day, an extract fan, and a ceiling with a loft directly above it. That is precisely the situation a tunnel was invented for.

What the roof over it is made of

Roof element What you typically find What it means for a tunnel
Roof form Hipped, often with a front gable or a bay roof below Hips and valleys are no-go areas for a roof opening
Rafters Cut timber at close, sometimes irregular, centres Dome position set out to the spacing you have, not the one you wanted
Purlin A substantial timber running the length of each slope Routes cross above or below it, adding deflection
Struts and binders Props off internal walls, ceiling binders at mid-span Frequently occupy exactly the diagonal you wanted
Covering Concrete interlocking tiles, often a later re-roof Standard flashings suit, unlike a Purbeck stone slate roof
Water tank Sitting over the landing on bearers Blocks the centre of the void; the tunnel moves, not the tank
Soil vent pipe Rising from the bathroom towards the ridge or through the roof Occupies the short direct route out of the room below

The route that usually works

In most of these houses the tunnel runs from a ceiling position over the open floor of the bathroom, up between two joists, then across and up to a rear-facing roof slope a short distance from the ridge. Rear rather than front for three reasons: the rear plane is usually the larger uninterrupted field of covering, it avoids the front gable and bay roof geometry, and it is not seen from the street, which matters in conservation terms in parts of the town.

The run is short by tunnel standards. That is the great advantage of this house type — the bathroom is under the middle of the roof, so there is very little horizontal distance to cover, and a mostly vertical route with one modest deflection is often achievable. A short, near-straight run is the condition in which a tunnel performs best.

The five obstructions that repeat

  1. The purlin. Almost always in the way of the neat diagonal. Going under it usually costs less light than going over, but it depends where the ceiling position is.
  2. The strut off the internal wall. Often landing directly over the bathroom’s dividing wall, which is exactly where people first propose putting the tunnel.
  3. The cold water tank. Over the landing, immovable, and the reason the ceiling position frequently ends up a metre from where it was first marked.
  4. The soil vent pipe. Rising from the room below. Clearances are respected and the tunnel crosses it at a different level.
  5. The airing cupboard and its pipework. The ceiling of the cupboard is often the easiest place to drop a tube, and the worst place, because the light then lives in the cupboard.
1930s Poole semis with internal bathrooms and no wall to reach
A landing that had no daylight of its own at all.

The airing cupboard temptation

A shortcut worth refusing

The clear route down is often over the airing cupboard, and that is not where the light is needed. A tunnel is aimed at a room, not at a hole in a ceiling. A diffuser tucked into a corner behind a cupboard door lights the cupboard, the top of a door frame and about a third of the room, and produces the complaint that a tunnel “does not really do much”.

The exception: where the cupboard is being removed as part of wider work, or where the cupboard ceiling genuinely sits within the open part of the room. Then it is simply a convenient clear route, and it is worth taking. The general point — that where the diffuser lands decides what the tunnel is worth — is set out in aiming a tunnel at the light you actually need.

The moisture problem in this exact room

An internal bathroom in an interwar semi is the wettest room in the house with the least means of drying itself. It has no openable window, so all the vapour from a shower leaves through an extract fan or it does not leave at all.

Putting a cold tube from a ventilated loft into that ceiling without sleeving and sealing it is asking for water at the diffuser within the first cold month. The sleeve runs the full length, the collar is sealed at the ceiling, and the extract fan is expected to be working and to run on after use. A tunnel adds daylight to that room; it does not ventilate it and does not reduce anything the building regulations require. The detail is on the condensation page.

Where these houses sit in the exposure map

Specification follows the zone, not the house type

The same 1930s semi appears across several Poole exposure zones and does not get the same materials in each. In Parkstone, Winton and Penn Hill the exposure is ordinary suburban and an ordinary specification is correct; marine-grade fixings there would be an overcharge and we will say so.

The same house at Lower Parkstone or Hamworthy is in harbour air with salt present but the prevailing south-westerly broken by land. Out towards Sandbanks, where a comparable house sits on the spit, salt-laden wind arrives with no fetch break and the dome, flashing and fixings are specified accordingly. In Branksome Park and Canford Cliffs the constraint is different again: pine canopy over the roof, needle debris on a small dome, and tree preservation orders that make trimming the canopy somebody else’s decision.

1930s Poole semis with internal bathrooms and no wall to reach
The roof end: a small dome that needs its own flashing like any other opening.

Order of works on the day

The sequence is worth knowing because it determines how long the house is open. The ceiling position is marked and checked from both sides. The tube run is dry-assembled in the loft to confirm it lands where it should. Only then is the roof opened, the covering carefully set aside, the flashing dressed in and the dome fitted, so the roof is weathertight again in the shortest possible window. The ceiling opening is cut last, the tube dropped in, sealed and sleeved, and the trim and diffuser fitted.

Cutting the ceiling first is the common shortcut, and it means the room is open to a loft for the rest of the day with plaster dust going everywhere.

When we tell you to fit a rooflight instead

The honest answer, including when it costs us the job

A sun tunnel is not a substitute for a rooflight where a rooflight would fit. In this house type there are two situations where that applies directly. First, if the bathroom has been extended or reorganised so that part of it now sits under its own rafters with no room above, a skylight in that ceiling will give far more daylight than a tunnel. Second, and more often, the landing.

A small square landing with a dark stairwell is frequently the real complaint, and a rooflight over the stair in the rear slope lights the landing, the stairs and the hall below it in a way no tunnel can approach. If that is what you actually want, we will quote for that, not for the smaller product. The comparison is set out in full on where a sun tunnel beats a rooflight.

What the survey settles in a house like this

We measure the bathroom, find that point from the loft side, establish joist direction and centres, locate the purlin, struts, tank, vent pipe and cabling, then identify the rear-slope roof positions that clear the hip and any chimney. From that we name the tube type and diameter, the number of turns, the diffuser and the exposure zone that sets the flashing and dome specification.

You get a fixed written price after survey and a ten-year workmanship guarantee, which is our own and is not insurance backed. To have one of these roofs looked at properly, ring 01202 923272.

Get a fixed quote

Get a fixed quote

Tell us which way your roof faces.

We will come back with a specification, not a catalogue page. If your extension faces south we will tell you the G-value we would fit and why.

  • No pressure, no doorstep sales call
  • We handle the Building Control notification
  • 10-year workmanship guarantee on every installation
  • Installations and replacements across Poole and south Dorset

Prefer to talk it through? 01202 923272