Triple glazing on a rooflight: weight, U-value and diminishing return

Why the step from double to triple is small on a domestic rooflight, what the third pane costs in weight, daylight and frame depth, and the specific cases where it is the right call after all.

U-value and g-value pull in opposite directionsU-value measures heat leaving through the unit; g-value measures solar energy coming in. A coating that cuts summer gain also cuts the winter daylight and warmth a room receives, which is why the right answer depends on orientation and on what shades the roof.solar energy ing-valueheat outU-valueglazed unitlowering one usually raises the other

The steps are not the same size

Almost every argument about triple glazing goes wrong in the same place: it treats the second upgrade as though it were the first. Single to double is transformative, because it introduces a cavity where there was none and cuts heat loss by a large fraction. Double to triple adds a second cavity to a unit that already has one, and improves on a number that is already small.

That is the shape of a diminishing return, and it is not a criticism of triple glazing. Triple is excellent in the right building. On a domestic rooflight in Dorset it usually is not the right answer, and the reasons are specific and physical rather than a matter of taste.

This page sets out the trade-offs in full. The short verdict, for anyone who only wants that, has triple glazing worth it in a rooflight.

Weight is the constraint nobody raises first

Glass weighs roughly 2.5kg per square metre for each millimetre of thickness. A third pane, with the extra spacer and seal that come with it, adds something in the region of ten to fifteen kilogrammes per square metre depending on the make-up — and it adds it overhead, on a structure that was designed for what was already there.

On a modest skylight that is an inconvenience. On a large flat rooflight over a kitchen it is a structural question, and it arrives in four places at once.

Where the weight lands What it asks for What happens if it is ignored
The frame A deeper, stronger profile designed for a triple unit. Not every system has one A frame carrying more than it was rated for, with the seal and the geometry paying for it over time
The kerb An upstand and fixings sized for the load, not for the unit that was originally specified Deflection at the kerb, which shows up as a unit that no longer sits square and an opening sash that binds
The trimmers and rafters below Checking against the added dead load, and on a large opening that is an engineer’s calculation Long-term deflection in the roof structure, usually noticed first as cracking at the reveal
Getting it onto the roof More lifting capacity, more access, and sometimes a crane where a hoist would have done A job that is not deliverable on the day, on a terraced Poole Old Town street with no rear access

The second cavity works less well lying down

A cavity lying near-horizontal convects more freely than the same cavity standing upright, because the warm pane is underneath the cold one and the gas is free to circulate across the whole face rather than through a narrow gap. That is true of a double unit and it is true twice over of a triple.

So the second cavity in a flat rooflight returns less than the first did, and less than the same second cavity would return in a wall. The theoretical step from double to triple shrinks precisely in the application people are considering it for.

There is a further squeeze on a slim frame. Fitting three panes into an ordinary frame depth means two narrower cavities, and a narrow cavity is below the optimum for argon, which is one of the situations where krypton stops being a luxury and starts being the only way of making the arithmetic work. That is another cost on top of the glass.

The daylight tax

Every pane reflects and absorbs a little of the light passing through it, and every coated surface takes a further slice. A triple unit has three panes and typically more coated surfaces than a double, so it passes less daylight than a double of equivalent quality. That is unavoidable and it is designed in rather than a defect.

On a wall window it is barely worth mentioning. On a rooflight it deserves attention, because a rooflight is usually there for one reason — to get daylight into a room that has no other way of getting any. Trading light transmittance for a fractional improvement in a U-value, in a hallway or an internal bathroom that was dark enough to need a skylight in the first place, is a bad trade made for a good-sounding reason.

Where the tax is worst

North-facing and permanently shaded roofs. No solar load to manage and every unit of daylight already scarce. Triple takes light out of the room with the least to give.

Under the pines at Canford Cliffs and Branksome Park. The canopy has already taken a share of the light, the trees are frequently protected and they are evergreen, so nothing improves in December. A triple unit under mature pine is paying twice to make a dim room dimmer.

Small openings. A modest rooflight has a high perimeter-to-area ratio, so a large part of what it delivers is already lost to frame and edge. Reducing the transmittance of what is left has a disproportionate effect.

Triple glazing on a rooflight: weight, U-value and diminishing return
Clear glass on a south slope in July. The light is the problem, not the heat alone.

Dew on the outside, and the October phone call

A high-performance unit lets so little heat reach its outer pane that the pane cools by radiation to a clear night sky and drops below the temperature of the air around it. Moisture in the air then condenses on the outside of the glass, and on a still autumn morning the whole rooflight goes milky until the sun clears it.

It is evidence that the unit is working, not that it is faulty. It is also the single most common call an installer of high-performance glazing gets in October, and a triple unit does it more often and for longer than a double.

This is worth knowing before you buy rather than after. On a roof you can see from the garden — a rear extension at Canford Heath, a flat rooflight over a Broadstone kitchen — external dew on a clear autumn morning is visible and it lasts. Nobody minds it once they know why it happens. Discovering it in the second week after installation, with nobody having mentioned it, is a different experience entirely, and it is the reason we raise it at survey.

Frame depth, sightlines and what it looks like from below

A triple unit needs a deeper frame, and on a rooflight the frame is directly in your view. A deeper profile means a heavier sightline round the pane, a taller upstand above the roof line, and a reveal that has to be formed around a thicker assembly. Overhead, all three read more strongly than they would at eye level in a wall.

On a conservation-profile skylight, where the whole point is a slim frame sitting flush in the tile or slate line, triple is often simply incompatible with the profile. On a visible roof slope in Poole Old Town or a listed building anywhere in the Dorset Council area, the depth of the frame is a planning consideration as well as an aesthetic one, and consent is assessed on merit rather than assured. The conservation rooflight pages cover how that is handled.

Opening units carry the weight twice

Everything above applies to a fixed pane. An opening one adds a second set of problems, because the weight now has to be moved as well as supported.

  1. Hinges and friction stays are rated for a sash weight. A triple sash can exceed what a system’s standard gear is designed to carry, which pushes you towards heavier ironmongery or a smaller sash.
  2. A manual sash becomes a two-hand job, and above a certain weight an unreasonable one from a pole or from a step.
  3. An electric actuator has to be specified for the load, and one working at the top of its range works harder on every cycle for twenty years.
  4. The gasket compression that keeps a sash weathertight is set up for a given sash. Change the weight and the closing behaviour changes with it.
  5. Servicing gets heavier. Replacing a failed actuator or a stay on a heavy sash overhead is a different job from doing it on a light one, and that is a twenty-year cost rather than a one-off.
Triple glazing on a rooflight: weight, U-value and diminishing return
The result the specification is aiming at: even light, no hot patch.

Sound is the reason people actually buy it

Most people asking about triple glazing on a rooflight are not really asking about heat. They are asking about rain noise, and on a flat skylight over a bedroom in a wet Dorset winter that is a legitimate complaint.

Triple does help, but it is not the most efficient way to buy the help. Acoustic performance comes mainly from mass, from asymmetry between the panes and from a laminated pane with an interlayer that damps vibration. A well-chosen double with a thick laminated inner pane and panes of differing thicknesses can outperform a symmetrical triple, at less weight and less cost, and the laminated inner pane is going in anyway because it is overhead glazing under Part K.

So when the driver is noise, the right conversation is about the make-up rather than the number of panes. Told plainly, that conversation usually ends somewhere cheaper than where it started.

When triple is the right answer

Four cases where we would specify it

A large glazed area designed for it from the outset. Where the structure, the frame system and the lifting were all planned around the weight, the objections above largely fall away.

A building working to a low-energy or passive standard. There the whole envelope is consistent, the fabric targets are demanding and a double-glazed rooflight would be the weak element in an otherwise coherent design.

A constrained cavity solved with krypton, in a system built for it. Where a manufacturer’s triple unit is engineered for the frame rather than squeezed into it.

Specific comfort requirements under the glass. A desk, a bed or a seat directly beneath a large pane, where the radiant coldness of the inner surface is what is being bought out rather than the heating bill.

Note what is not on that list: an ordinary domestic rooflight, bolted onto a kerb that was built for a double unit, in a house where nothing else has been upgraded. In that setting the third pane is money that would do more good in the kerb insulation, the edge seal and the reveal detail.

What we do instead, and what we will not claim

Our default across the service area is a well-specified double: low-emissivity coating on surface 3, solar control on surface 2 where the aspect warrants it, argon fill, a warm edge spacer in a dual-sealed unit, a toughened outer pane and a laminated inner pane. That sits comfortably inside the 2.2 W/m²K limiting standard for a replacement, and the manufacturer’s declared whole-unit figure is what governs on the quotation.

We will not tell you how many pounds a triple unit would save you or how long it would take to pay for itself. That depends on the house, the heating, the occupancy and the weather, and any figure we produced would be a guess dressed as a fact. We will tell you what the third pane weighs, what it does to the frame and the structure, what it takes out of the daylight and what it does on a clear October morning.

Our installation work carries a ten-year workmanship guarantee, stated plainly as a workmanship guarantee and not insurance backed, with a fixed written price after survey. If someone has quoted you triple for a domestic skylight in Poole, ring 01202 923272 and we will go through which of the four cases above it falls into — and say so if it falls into none of them.

Get a fixed quote

Get a fixed quote

Tell us which way your roof faces.

We will come back with a specification, not a catalogue page. If your extension faces south we will tell you the G-value we would fit and why.

  • No pressure, no doorstep sales call
  • We handle the Building Control notification
  • 10-year workmanship guarantee on every installation
  • Installations and replacements across Poole and south Dorset

Prefer to talk it through? 01202 923272