Sun Tunnel Installation in Poole
Tubular daylight into Poole rooms that have no window and no roof plane of their own, from tube type, diameter and route through dome, diffuser and the exposure zone the specification follows.

A sun tunnel is its own product, not a budget rooflight
A sun tunnel takes daylight from a dome on the roof, carries it down a reflective tube through the loft, and delivers it through a diffuser set flush in the ceiling. It is for the rooms in ordinary Poole houses with no external wall and no roof plane of their own: internal hallways, landings, en-suites, utility rooms and stairwells.
What it is not is a cheaper skylight. Where a room sits under a roof plane with space between the rafters, a rooflight gives more daylight, a view of the sky and ventilation. A tunnel gives daylight and nothing else. If you have been quoted a tunnel for a room where a rooflight would fit, ask why.
The rule, and the exception
The rule: if a rooflight will fit above the room, fit a rooflight. A sun tunnel is for the rooms where one will not, because a floor, a loft room or several metres of roof void sits between that ceiling and the sky.
The exception: a ground-floor hall, or a bathroom under an unconverted loft the owner still wants. There the tunnel is the only route daylight has, and it costs a circle of loft floor about the width of a dinner plate.

Rigid or flexible: the corrugations are the whole argument
The tube is a mirror rolled into a cylinder. Light entering the dome does not travel straight down it — most arrives at an angle and bounces its way to the ceiling, and every bounce costs a fraction.
Rigid tube is a smooth specular sheet; manufacturers quote reflectivity in the high nineties per bounce. Flexible tube is corrugated foil, and the corrugations are what let it bend. Each rib scatters part of the beam and steepens the angle of the rest, so flexible loses light twice over: more at every bounce, and more bounces.

| What it comes down to | Rigid tube | Flexible tube |
|---|---|---|
| Inner surface | Smooth specular mirror, high-nineties reflectivity per bounce | Corrugated foil; every rib scatters, so each bounce costs more |
| Sensible run | Several metres, elbows included, still reading as daylight | A short drop only; beyond that the room looks lit, not daylit |
| Changing direction | Elbows at known angles, planned on paper and counted | Bends anywhere — which is the trap, because nobody sees the cost |
| Quality of light | White and directional; a genuine patch of sun on a clear morning | Flattens to grey-white; the sunny quality goes before the brightness |
We fit rigid as standard. Flexible has one honest use: a short, near-straight drop where a rigid elbow will not thread the structure. If we propose it, we say why.
Run length, bends, and where the loss becomes obvious
Everybody asks how far a tunnel can go. The better question is how often it has to turn. Distance costs light steadily; a bend costs it in a step. One gentle offset round a purlin is invisible in the room. Two are not.
| The route | What happens to the light | What you see in the room |
|---|---|---|
| Short straight drop, bathroom under an unconverted loft | Very little lost; the tube is barely working | Bright white disc, and a moving patch of sun on a clear day |
| Longer straight run, hall boxed through the floor above | Steady loss with distance, but rigid tube holds the colour | Softer, hard edges gone, still clearly daylight |
| Two or more bends, or one tight elbow | A step down at every turn, compounding along the run | The room lights but stops feeling sunny |
| A long run in flexible tube | Both losses at once: more per bounce, more bounces | A dull grey disc, and the ceiling light goes on anyway |
Diameter, and the room it will actually light
Two sizes cover most domestic work: roughly 250mm and roughly 350mm. That sounds like a small step and it is not. The light a tube carries follows its cross-sectional area, and area goes with the square of the diameter — so 350mm is about 1.4 times the width and carries close to twice the light, for nothing like twice the price. We will not quote you a lumen figure: the honest answer depends on the sky, the roof plane’s orientation, the run, the bend count and the colour of your walls.

| Around 250mm | Around 350mm | |
|---|---|---|
| Light delivered | The baseline for a small internal room | Close to double on the same run |
| Suits | En-suite, cloakroom, small landing, short hallway | Family bathroom, long hallway, stairwell, utility room |
| Ceiling opening | Usually drops between joists at 400mm centres, no trimming | Will not clear 400mm centres; expect a joist trimmed and hung properly |
| Where it disappoints | A big room: lights what sits under it, leaves the ends dim | Rarely the diameter. When it underwhelms, the route is why |
In a long hallway, two 250mm tunnels usually beat one 350mm. A corridor does not want one bright pool and two dark ends, it wants light along its length — which only shows up once somebody has stood in the hall.
Routing between joists and around what is already up there
Lofts are full. The straight line from the middle of your ceiling to the middle of the roof slope rarely exists, because something already lives in it: a purlin, the cold water tank, the soil vent pipe, extract ducting from the bathroom below, cable runs, downlights.
The one that stops jobs is a trussed roof. A trussed rafter is an engineered component and its webs are structural, so nothing in it is cut or notched without the truss designer agreeing. The tube threads the gaps that already exist, which a 250mm rigid tube often can and a 350mm one often cannot. Sometimes it will not go, and we would rather say so at survey than halfway through the job.
- Mark the diffuser position from below. In a hall you want light nearer the doors people walk to, not the centre of the ceiling.
- Pilot through and find it in the loft. One small hole beats an hour of measuring from underneath.
- Read the structure. Joist direction and centres, purlins, binders, truss webs.
- Find the services. Soil vent pipe, extract duct, tank and pipework, cables, downlight clearances.
- Set the roof position from inside. Which tile or slate interval, clear of ridge, hip and valley, on a plane facing open sky.
- Measure the true run and count the bends, which decides rigid or flexible and the diameter.
- Agree both positions in writing before anything is ordered or cut.

Poole is four exposures, not one
A sun tunnel has two parts living outdoors: the dome, and the flashing tying it into the roof covering. Both are exposure items, and the town wraps around the harbour, so within four miles the conditions change completely. A specification right for Creekmoor is under-specified at Sandbanks; the Sandbanks build-up repeated inland is an overcharge.

| Exposure zone | Where | What it changes | Why |
|---|---|---|---|
| Zone 1 — severe marine | Sandbanks, the harbour mouth, seaward Lilliput | A4 (316) stainless fixings, non-ferrous flashing, a dome specified for salt and UV | Salt-laden wind, no fetch break; lesser fixings bleed rust down a slate in two winters |
| Zone 2 — sheltered marine | Poole Old Town, the Quay, Hamworthy waterside, Parkstone shore | Coastal-grade fixings where exposed, dome position chosen for the street view | The land behind breaks the south-westerly; conservation status limits which plane is available |
| Zone 3 — wooded and elevated | Canford Cliffs, Branksome Park, upper Lilliput | A dome that sheds debris, a position you can reach to clean, and a frank answer on whether to fit one | A protected pine canopy drops needles all year and takes daylight before it reaches the roof |
| Zone 4 — inland | Broadstone, Creekmoor, Canford Heath, Upton | Standard fixings, dome and flashing; coastal upgrades only if you want them | Sheltered heathland edge, no salt load — marine-grade here is money spent on nothing |
Sandbanks and Creekmoor are four miles apart and are not the same roof. One sits on a sand spit with open water either side, taking the prevailing south-westerly with nothing in its way. The other sits on the heathland edge with the whole town in front of it. We name the zone at survey and write it on the quote with the reason attached.
Under the pines: what a canopy does to a tunnel
A sun tunnel collects whatever lands on its dome, and in Canford Cliffs and Branksome Park what lands is pine needles. The clamp ring and flashing collar give needles a rim to gather against, and once packed that collar holds water against the flashing and shades the dome. The light goes over two or three seasons, so nobody notices it happening — they notice the hall is darker and assume the tunnel has failed.
The bigger problem under a canopy is shade. A rooflight presents a large area of glass to a large area of sky, so partial shade costs it part of its light. A tunnel has one small aperture, and if that sits in shade most of the day, no diameter and no reflectivity spares you.
Tree preservation orders here mean the canopy is permanent, so it is a design input rather than a nuisance. We survey the dome position for sky as much as for structure. Where the only roof plane available sits under pines most of the day, we say so — and if the room can take one, that a skylight on a clearer plane is the better use of the money.

The dome: shape, material and what it has to survive
Profile matters more than people expect. A raised dome catches low winter sun arriving from the side, which is exactly when an internal hallway has nothing else. A flush unit looks better from the street and sheds debris better, and gives up some of that low-angle gain to do it. A prismatic top turns shallow winter light down the tube — a real gain in January, marginal in June, and no substitute for shortening a bad run.

| Dome type | Where it earns its place | What to watch |
|---|---|---|
| Clear domed acrylic | The default on most pitched roofs; the raised profile gathers low winter sun | Acrylic is soft. It marks, and under pines the rim collects needles |
| Low-profile flat glass | Prominent front slopes and conservation roofs around the Old Town and the Quay | Less low-angle light in December and January, and a higher cost |
| Upstand-mounted for a flat roof | Utility rooms and halls under a flat roof, the dome clear of standing water | The upstand must be insulated, or it is a cold bridge and a wet collar by February |
A tunnel is not a vent. If a windowless bathroom needs extraction, that is a separate duct through a separate hole. Combining the two because both are round is how damp air ends up in a cold void.
Condensation in a cold loft, and how the tube is insulated
A sun tunnel runs a metal cylinder from a warm ceiling into a cold, ventilated roof space. On a February night that tube sits at loft temperature, below the dew point of the air around it. Moisture condenses, runs down, and appears as a wet ring round the diffuser next morning. Every homeowner reports that as a leak. Almost none of them are.
Three things stop it, and only together: a sealed collar at the ceiling, so warm moist room air never enters the tube; a continuous insulated sleeve through the cold zone, taped and not crushed where it passes a joist; and loft ventilation that still works afterwards.
The rule, and the exception
The rule: any tube passing through a cold ventilated loft gets a continuous insulated sleeve and a sealed ceiling collar. No run is short enough to skip it, and a short run over a shower is the worst place to try.
The exception: a warm-roof build-up, where insulation follows the rafter line and the void sits inside the thermal envelope. There the tube is in warm space and the sleeve is not doing the same job, though the sealed collar still matters. The dome is a cold surface whatever we do, so light misting inside it above a shower in January is physics, not a defect.
The diffuser, and a light kit for after dark
The diffuser is the only part of the job you will actually look at, and its face decides how the light behaves once it arrives. A plain opal disc reads soft and even, which suits a bathroom. A prismatic or textured face throws light wider along its axis, which is what a hallway wants: spread, not a pool. Too clear and you see a glaring disc; too heavily diffused and you have thrown away light you paid several bounces to keep.
After dark a sun tunnel is a blank circle, and in a windowless bathroom that matters. Most ranges take a low-voltage LED mounted inside the tube just above the diffuser, wired onto the room’s lighting circuit. Do it at the same visit, while the loft is open and the tube is not yet sealed.
Two caveats. Adding to a circuit in a room containing a bath or shower is notifiable work in England, so it goes to a registered electrician who can self-certify, or through Building Control at BCP Council. And a light kit is a convenience, not a lighting design — the extract fan and a light over the mirror are still wanted.
What the survey settles, and why none of it works over the phone
We do not price a sun tunnel from a photograph of a ceiling. Almost everything that decides whether it is any good is in the loft.
| What the survey settles | Why a description will not do |
|---|---|
| Where diffuser and dome go | The dome needs a plane facing open sky, clear of ridge, hip and valley — and of the street view in a conservation area |
| The structure and the services | Joist centres, cut roof or trussed, and where the soil pipe, ducting, tank and cables actually run |
| The exposure zone | Fixing grade, flashing and dome specification follow from it, and the zone goes on the quote |
| Whether a tunnel is right at all | Sometimes a rooflight fits and gives more; sometimes a pine canopy makes a tunnel pointless |
| The price | One fixed written figure, with making good and electrical work shown separately |
Fitting day, in order
- Protection and set-up. Floors and sanitaryware covered; enough light and boarding to work safely in the loft.
- Positions confirmed against the survey and agreed with you before a single cut is made.
- Ceiling opening. Circle cut to the collar size, a joist trimmed and properly hung if the diameter needs it, collar set level.
- Roof opening. Tiles or slates lifted, opening cut through batten and underlay, the underlay dressed and supported so it still carries water to the gutter.
- Flashing set. Chosen for the roof covering rather than for the tunnel, dressed under the courses above and over those below, at the zone’s fixing grade.
- Tube run and sealed. Elbows set to the planned angles, joints taped, insulated sleeve continuous through the cold zone, sealed at dome and ceiling.
- Dome and diffuser. Dome seated and sealed, light kit wired if in scope, diffuser clipped in, ceiling made good.
- Check and hand over. Flashing water-tested, loft checked for daylight leaks round the collar, site cleared, paperwork handed over.
A single tunnel on an accessible cut roof is normally one day; two in the same loft usually still one. A trussed roof needing a designed route, or notifiable electrical work, adds a visit — and we say so before you commit.
What we put in writing, and what we will not claim
This is a new firm in Poole. What it offers instead is written down and checkable.
The two things we put in writing
A ten-year workmanship guarantee on our installation: the flashing, the tube, the seals and the ceiling detail. It is not insurance backed, and we say so plainly, because the difference is real. Domes, tubes and diffusers carry their own manufacturer warranties.
A fixed written price after survey. Not a range, not a guide figure, not something that grows once the hatch is open. If something genuinely unforeseeable turns up — a trussed roof described to us as cut, a soil pipe exactly where the tube wanted to be — we stop, show you, and price the alternative before going further.
Sun tunnels are one of the things we install across Poole and about thirty miles around it, alongside flat rooflights, roof windows, roof lanterns and the replacement of failed units. We install and replace glazing; we are not a general roofing firm, and we will not fit a sun tunnel where a skylight would serve you better. If you have a dark hallway, a windowless en-suite or a landing that has never seen daylight, ring 01202 923272. We will name your exposure zone over the phone. Everything after that needs somebody in the loft.
In this section
1930s Poole semis with internal bathrooms and no wall to reach
The interwar semi built across Parkstone, Winton, Penn Hill and Oakdale has a recognisable problem: a bathroom in the middle…
Adding a light kit so the tunnel works after dark
A sun tunnel goes dark when the sky does. In a bathroom or a hall that had no daylight at…
Are sun tunnels warm or do they lose heat?
A sun tunnel is a hole through your insulated ceiling, so yes, it loses some heat — and a properly…
Broadstone bungalows where the loft void is shallow and wide
Broadstone, Creekmoor and the bungalow runs out towards Corfe Mullen were built low and built wide. Every room sits on…
Can a sun tunnel be fitted in a bathroom?
Yes. A windowless internal bathroom or en-suite is the single most common place a sun tunnel earns its keep, and…
Can a sun tunnel be fitted into a Purbeck stone slate roof?
Yes, but not with a kit. Purbeck stone slates are thick, heavy and laid in diminishing courses, and there is…
Can a sun tunnel be fitted through two floors?
Physically, yes — a tunnel can be run from a roof, through a loft, down through a first floor and…
Can a sun tunnel be fitted to a flat roof?
Yes, technically. A flat-roof sun tunnel sits on a kerb that lifts the opening clear of the deck, with the…
Can a sun tunnel go round a corner?
Yes. Rigid tunnels turn using purpose-made elbows, and flexible tube bends by hand anywhere along its length. The real question…
Can a sun tunnel reach a hallway in a Canford Heath house?
Usually yes. Hallways and landings in Canford Heath houses sit near the middle of the plan, which means a short…
Ceiling position: aiming a tunnel at the light you actually need
Almost every sun tunnel gets put in the middle of the ceiling, and in perhaps half of those rooms the…
Condensation in a sun tunnel and the insulation sleeve that stops it
A sun tunnel drips because a cold surface has met warm wet air, not because the roof is leaking. The…