EDW, EDL and EDJ flashings matched to the roof covering
The flashing family is chosen by the profile depth of the roof covering, not by the window, and on Dorset roofs that choice runs from deep clay pantile through slate to stone slates that no standard kit fits at all.
A roof window almost never leaks through the window. It leaks at the junction between the window and the roof, which is a separate product, ordered separately, and chosen by the covering rather than by the unit.
That sentence is the whole of this guide, and it is the single most expensive thing homeowners do not know. A skylight bought online arrives in a box with no flashing in it. The flashing is a discrete kit with its own code, and the code is decided by what the roof is covered in and how deep its profile runs. Get it wrong and you have a correctly fitted rooflight sitting in an incorrectly formed junction, which is a leak with a delay built into it.
The three families you will meet
| Flashing family | Made for | Typical Dorset covering |
|---|---|---|
| EDW | Profiled coverings, standard installation, up to a deep profile | Clay and concrete pantiles, Double Roman, deep interlocking concrete tiles |
| EDL | Flat coverings of limited thickness, standard installation | Natural and fibre cement slate, plain clay tile, some shingles |
| EDJ | Profiled coverings where the window sits recessed into the roof plane | The same tiles as EDW, but with the unit set lower for a flush appearance |
There is a fourth in common use, the recessed equivalent for flat coverings, which does for slate what EDJ does for pantile. Between them these cover the great majority of British roofs. What none of them covers is a roof whose covering falls outside the profile and thickness limits they are made to, and Dorset has a well-known example of exactly that.
Profile depth is a measurement, not a description
The distinction between the profiled and flat families is not a judgement call. It is the vertical distance from the lowest point of the covering to the highest, measured with a rule across the tiles. A flat covering sits within a few millimetres of one plane; a profiled one rises and falls in a wave, and the flashing has to be pressed into that wave to stay watertight against it.
Two roofs that look similar from the pavement can fall either side of the line. A plain clay tile roof in Wimborne and a clay pantile roof two streets away are different families entirely, and the difference is visible only when you get close enough to see the section.
Old Dorset clay pantiles are rarely uniform. Hand-made and early machine-made pantiles vary in camber across a single roof, and a stack of reclaimed tiles varies more. The flashing is specified against the deepest profile present around the opening, not the average. We measure at the actual position of the proposed window rather than at the eaves where it is easy to reach.
Purbeck stone slates, where no standard kit fits
South and west of the harbour the roofs change. Corfe Castle, Langton Matravers, parts of Swanage and the villages between them carry Purbeck stone slates: heavy, thick, irregular in both plan and section, and diminishing in course size up the slope. They are a magnificent roof and they sit outside every standard flashing kit on the market, because the thickness alone exceeds what a flat-covering flashing is made to accommodate and the irregularity defeats a profiled one.
The answer on those roofs is a purpose-formed lead or code-equivalent detail, made on site to the stones actually around the opening, usually in combination with the window manufacturer’s underfelt collar to handle drainage beneath the covering. It is slower, it is a different skill, and it is the only honest way to do it. Anyone offering a boxed kit for a stone slate roof has not looked at the roof.
Purbeck roofs carry a planning question as well as a technical one. Corfe Castle, Langton Matravers and much of the Isle of Purbeck fall under Dorset Council rather than BCP, sit within the Dorset National Landscape, and include conservation areas and listed buildings in quantity. Whether a new opening in a stone slate roof is acceptable at all is assessed on its merits by the authority, and no installer can promise you an outcome. We will tell you what the application will need; we will not tell you it is a formality.

Standard or recessed: what the J changes
EDW and EDJ serve the same tiles. The difference is how far into the roof build-up the window sits. A standard installation keeps the frame proud of the covering in the usual way. A recessed installation drops it lower, so the glass sits closer to the plane of the tiles and the unit reads as part of the roof rather than as an object on it.
The visual difference is significant from the ground and it has consequences inside the room as well, which is why recessed installation has its own guide rather than a paragraph here. What belongs on this page is the ordering consequence: the decision to recess is made before the flashing is bought, because it changes which kit you need. It is not a change of mind you can have on the second day.
Two windows side by side need a different kit again
Where units are fitted in a pair or a run, the flashing between them is not the same component as the flashing around the outside. Combination flashing kits exist for exactly this, in both the profiled and flat families, and they set the gap between the frames. That gap is fixed by the kit, not chosen on site.
This catches people who decide to add a second window later, next to the first. The spacing that a combination kit requires is rarely the spacing that looks natural when you are standing in the room pointing at the ceiling, and the two windows have to be positioned to the kit.
What the flashing does not do
A flashing kit manages water above the covering. It does not manage water that has already got beneath the tiles, and on any roof there will be some: wind-driven rain past a pantile lap is normal, not a fault. That water is handled by the underlay and by a separate underfelt collar which drains it around the frame and back onto the underlay below.
Leaving that collar out is the most common defect we find on windows fitted by a general builder rather than a roofer. Everything above the tiles looks textbook. The water arrives in the room anyway, six months later, usually during the first proper south-westerly.
How to read a damp patch
Water appearing at the head of the reveal after wind-driven rain usually means the underlay and collar detail, not the visible flashing.
Water at the sill or the bottom corners, in ordinary rain more often means the apron, the tile course below the window, or a blocked drainage channel in the sash.
Water that appears in cold weather without rain is very often not a leak at all. That has its own answer page, because condensation and ingress get confused constantly and the remedies are opposites.

Salt, zinc and what the coast does to a flashing
Flashing kits are largely zinc or aluminium with a factory finish, and both weather. Inland, across Broadstone, Ferndown and Verwood, they weather slowly and predictably and nothing special is required. On the sand spit at Sandbanks and Studland, where salt-laden wind arrives with nothing to break it, surface deterioration runs measurably faster and the fixings are as important as the sheet.
Our position on the spit is stainless fixings throughout and a realistic inspection interval agreed at handover, rather than a claim that any product is immune. Nothing exposed to that atmosphere is immune. What changes is how long it takes and whether anyone is looking.
Ordering: the sequence that avoids a second delivery
- Identify the covering by type and measure its profile depth at the proposed opening.
- Decide standard or recessed, because that choice selects the flashing family.
- Count the units: single, or a combination that needs its own kit between frames.
- Match the flashing size code to the window size code; they correspond, and a mismatch is not adaptable.
- Add the underfelt collar and the insulation collar as separate line items, because they are separate items.
- Check whether the covering can be re-laid at all, which on brittle old pantiles and on stone slates is a genuine question with a cost attached.
We are not a VELUX-appointed installer and hold no accreditation from them; the codes on this page are the manufacturer’s published product families, quoted as product facts. What we do is specify the junction correctly for the roof in front of us, fit it, and back our own work with a ten-year workmanship guarantee that is given directly by us and is not insurance backed. If your roof is stone, pantile or anything a supplier has been vague about, call 01202 923272 and we will look at it before anything is ordered.
Related reading
Can a VELUX be converted from manual to electric?
Usually yes, if the unit is from roughly the last twenty years. A retro-fit kit replaces the top control bar…
Can a VELUX be fitted to a flat roof?
Not as it comes. A standard pitched-roof unit needs a slope of roughly fifteen degrees or more to shed water…
Can a VELUX be fitted to a roof with solar panels?
Yes, but it stops being a roofing question and becomes a clearance and sequencing one. A flashing needs a clear…
Can a VELUX be replaced with the same size unit?
Usually yes. The standard size grid has been stable for decades, so a like-for-like frame is normally available, but “same…
Can a VELUX window be repaired?
Yes, more often than not. Glass, gaskets, filters, handles, friction components and flashings are all replaceable on their own. The…
Can I fit a blind to an old VELUX window?