Like for like replacement when the original size is no longer made
An obsolete rooflight size is a lead time rather than a dead end, once the question moves from matching a catalogue product to measuring the opening.
Somewhere on most 1990s extensions in Poole there is a rooflight that cannot be bought any more. Not a rare one, not an exotic one. An ordinary skylight, in an ordinary size, made by a company that has either rationalised its range, changed its system, or closed. The owner asks for a like-for-like replacement and is told the size does not exist, which sounds like the end of the conversation and almost never is.
The phrase itself is the problem. “Like for like” is usually meant as the same product, when what actually matters is the same hole. Once you move the question from catalogue to opening, an obsolete size stops being a dead end and becomes a lead time.
Why the size went away in the first place
There are four common reasons, and they lead to different answers, so it is worth knowing which one you are dealing with.
| Reason the size vanished | How you recognise it | What it means for the replacement |
|---|---|---|
| The range was rationalised | The maker still trades and still makes rooflights, just not that one | Usually the easiest case. A current product is made to the same opening |
| Imperial or nominal legacy sizing | The opening measures to something awkward, close to an even number of feet | A made-to-order unit is specified to the measured metric dimension |
| The manufacturer stopped trading | No trace of the brand, and no parts anywhere | A current make is specified to fit. Nothing of the original is reused |
| There never was a catalogue size | A builder-formed timber kerb, no two dimensions round | Entirely normal, and the most common case of all. It was bespoke when it was new |
The last row is the one that surprises people. On a great many extensions built through the 1990s and early 2000s, the carpenter framed an upstand from whatever the joists and timber allowed, and glass was ordered afterwards to suit. There was no standard size to lose.
Measuring a kerb that is not square
Before any of this can be answered, the opening has to be measured properly, and an old kerb is rarely the neat rectangle it appears from the ground. Twenty years of thermal movement, a deck that has taken a set, and a timber upstand built in a hurry all conspire.
- Both widths and both heights, taken at the top of the upstand where the unit actually sits, not at deck level.
- Both diagonals. A difference of more than a few millimetres means the opening is out of square, and the new unit has to be made to the smallest rectangle that fits inside it.
- The height of the upstand above the finished surface of the roof covering, taken on all four sides, since flat roofs are not flat and one corner is usually lower.
- Whether the top of the kerb is level across its width, or whether it twists. A twisted kerb will not bed a rigid unit evenly and has to be corrected, not packed.
- Internal and external measurements both, because manufacturers quote to different conventions and the wrong one is how a unit arrives 100mm out.
- Photographs of each corner, inside and out, which catch the rot and the missing insulation that a tape does not.
Internal, external and structural: the three sizes people confuse
An order form asks for a size and does not always say which one, and this is where a replacement most often goes wrong on paper rather than on the roof. A flat glass rooflight may be quoted on the external frame dimension, on the internal daylight opening, or on the kerb it is designed to sit over. Those are three different numbers for the same product, and the gap between the largest and the smallest can be well over 100mm.
We quote against the measured kerb and we state on the order which convention has been used. If a supplier will not say which dimension their figure refers to, that is the question to press rather than the price.
The three routes out of an obsolete size
| Route | When it applies | What the work involves | What it does to the programme |
|---|---|---|---|
| Made to measure | Flat glass rooflights and lanterns, which are mostly made to order anyway | Nothing structural. The unit is manufactured to the survey dimensions | Adds manufacturing lead time and nothing else. One visit to fit |
| Nearest size, opening adapted | Stock-size products, and roof windows in particular | The next size down, with the opening lined, packed and made good internally | Modest carpentry and plastering, and a slightly smaller daylight opening |
| Opening altered | Where the available product is larger, or where the old opening was wrong | Structure cut or trimmed, kerb rebuilt, covering dressed in | Longest route, brings Building Control into it, and is sometimes the right answer anyway |

Made to order is now the normal answer
Twenty years ago a non-standard flat rooflight meant a specialist and a long wait. Today most flat glass rooflights and almost all lanterns are manufactured to the customer’s dimensions as a matter of course, within a range of minimum and maximum sizes and subject to pane size limits. The practical consequence is that “they do not make that size” is usually a statement about one supplier’s stock list rather than about the market.
What made-to-order does change is sequence. The unit cannot be ordered until the kerb has been measured, and the kerb cannot always be measured accurately until the old unit is out. Where that is the case we survey, order, and only then book the fitting day, so the roof is never open waiting for glass. Where the measurement can be taken confidently with the old unit in place, which is most of the time, the whole job is one visit.
Adapting an opening, and the point at which it becomes carpentry
Fitting a smaller unit into a larger opening is respectable work when it is done properly and a bodge when it is not. Done properly, the kerb is reframed in treated timber to the new dimension, insulated continuously round the perimeter, the covering is dressed up and over the new upstand, and the internal reveal is re-lined and re-plastered so the finish looks intentional. Done badly, the gap is packed with offcuts and filled with sealant, which leaves a cold bridge, a water path and a line that will crack within a year.
The honest test is whether the alteration is visible from inside a year later. If the reveal reads as a designed opening rather than a patched one, and the line between old plaster and new has not cracked, the kerb underneath was reframed rather than packed. A hairline crack appearing round three sides of a reveal in the first winter is almost always telling you that offcuts and sealant were used where timber and insulation were needed.
Roof windows are the awkward case
Flat rooflights are made to order; pitched roof windows are overwhelmingly made to a size grid, because the flashing kit that weathers them into the tile or slate is made to the same grid. That makes an obsolete roof window size a harder problem than an obsolete flat rooflight, because the size and the weathering are locked together.
In practice this normally resolves into taking the nearest current size and adjusting the opening in the roof to suit, with the batten and tile courses reset around the new flashing. It is more work than a flat rooflight swap and it is thoroughly routine. Where the original is a branded roof window whose size code has simply been dropped, there is a separate route through equivalent codes, and that belongs with the roof window and branded-unit guidance rather than here.
Domes, imperial sizes and the pre-2000 kerb
Be careful with a “matching” unit
If a supplier offers you an exact replacement dome or unit for a product whose manufacturer stopped trading years ago, ask what it actually is. Sometimes it is genuine old stock, in which case it has been sitting in a warehouse for a decade and its seals have been ageing the whole time. Sometimes it is a generic unit being sold under a name. Neither is necessarily wrong, but neither is the guarantee of a perfect fit that the word “matching” implies.
Our position is that a measured opening and a current, supported product beats a nominal match every time, because a current product has parts, a manufacturer warranty and somebody to ring in five years.

What an obsolete size does not excuse
Two things get quietly smuggled in under the heading of “nothing else would fit”. The first is a unit forced into a rebate too shallow to give it proper edge cover, which shortens the life of the new glass for exactly the reason the old glass failed. The second is an upstand left at its original height because raising it would have meant touching the covering. On this coast, where driven rain arrives with the south-westerly off the harbour, a low upstand is a defect rather than a style.
If the only unit that fits the existing opening is one we would not stand behind, we say that, give you the measurement that makes it true, and price the alteration as a separate line you are free to decline.
Where the old size is worth keeping and where it is not
A replacement is the one chance to change the opening at a sensible cost, because the covering is already being disturbed and the reveal is already being made good. It is worth asking whether the original size was right. A 1990s skylight was often sized by what was available rather than by the room, and a longer unit in the same width, or two units where there was one, can change a room completely for a modest addition to the work.
Change it now or keep it as it is
Worth changing. Where the room has always been dim at one end, where a single narrow unit was chosen because it was in stock, or where the opening sits over a corridor rather than over the space people use. The covering and the reveal are already being disturbed, so the extra work is at its cheapest it will ever be.
Worth keeping. Where the existing skylight suits the room, the kerb is square and sound and the structure around it is undisturbed. Then the size stays, you pay for glazing rather than carpentry, and we will say so rather than talk you into a bigger opening.
What we settle before anything is ordered
The survey ends with the opening measured to the conventions the manufacturer actually uses, the route named, the lead time stated and the price fixed in writing, with any carpentry shown as its own line. Our own work carries a ten-year workmanship guarantee, given directly by us and not insurance backed. If you have been told your rooflight size is no longer made, ring 01202 923272 with the rough dimensions and we will tell you which of the three routes your roof is on.
Related reading
Are 1990s rooflights on Poole extensions worth replacing now?
In most cases yes, and usually not for the reason people expect. A 1990s unit that has misted is finished…
Can a leaking rooflight be resealed instead of replaced?
Sometimes, where the leak is at a gasket, a termination or a joint that can genuinely be renewed. But the…
Can a misted rooflight be repaired?
Sometimes, but not in the way most people mean. The misting itself cannot be cured, because the fault is inside…
Can a misted unit be replaced with a larger one?
Yes, and it is often worth doing while the roof is open. But be clear what you are agreeing to:…
Can a rooflight be replaced in one day?
The fitting usually is, yes. One rooflight, on a roof that can be reached, onto a kerb that turns out…
Can an old dome rooflight be swapped for flat glass?
Yes, and it is one of the replacements people are most pleased with afterwards. The work is usually straightforward, because…