Flashing kits for plain tile, pantile and slate, and where they differ

How a roof window flashing kit is chosen by the covering it interleaves with, and what goes wrong when the wrong family of kit is fitted.

A roof window set between rafters in a pitched coveringThe window sits in the plane of the covering between existing rafters. A flashing kit matched to the covering carries water around the frame, and the underlay is dressed to a collar so anything passing the tiles is returned to the outside.roof windowrafterrafterflashing kitcovering

The window is not what keeps the water out

A roof window is a sealed box with glass in it. Left sitting in a hole, it would leak within a day. What actually keeps the roof watertight is the flashing kit around it: a set of pressed metal sections that interleave with the courses of tile or slate so that every drop of water arriving from above is delivered back onto the covering below the window, never behind it.

Because the kit has to interleave, it has to match what it is interleaving with. A flashing designed to lie flat on slate will not seal against the curve of a pantile. A kit designed to sit over a 30mm profile will stand proud on a flat covering and let wind-driven rain under the apron. This is the most common reason a new roof window leaks, and it is almost always reported to us as a faulty window.

What is actually in the box

Kits vary between manufacturers, but the anatomy is consistent, and knowing the names makes the rest of this page readable.

Component Where it goes What it does
Apron Below the window, dressed down over the course beneath Delivers everything the window sheds back onto the covering. The last line and the one that shows
Side sections or soakers Up each side, one per tile or slate course Forms a lined gutter between frame and covering, each piece lapped by the one above
Head flashing Above the window, under the courses above Splits the water arriving down the slope and sends it round both sides
Cladding or frame trims Clipped onto the frame itself Covers the joint between frame and flashing, and takes the ultraviolet
Underlay collar Beneath everything, onto the roofing membrane Second line of defence. Often sold separately and the piece most often skipped

The kit is not decorative trim. Every piece is a water path, and the sequence they go on in is as much a part of the design as the pressings themselves.

Profile height chooses the kit

Strip away the product codes and there is one number underneath: how far the covering stands proud, measured from the flat face of the batten line to the top of the tile at its highest point. That single dimension puts your roof into one of three or four families.

Covering Rough profile height Kit family Where you see it around Poole
Natural or fibre cement slate Under about 10mm Flat covering Victorian and Edwardian villas, Parkstone, Westbourne, the Old Town
Plain clay or concrete tile Around 10mm to 16mm Flat covering Inter-war semis, much of Branksome and Penn Hill
Clay or concrete pantile Around 25mm to 45mm Profiled covering Very common across Dorset, older and newer stock alike
Interlocking concrete, deep pan Around 45mm and upwards Deep profile Post-war estates, Creekmoor, Canford Heath, Corfe Mullen
Purbeck or other stone slate Irregular, thick, never consistent None. Bespoke leadwork Corfe Castle, Langton Matravers, Worth, the Purbeck villages

Measure it rather than assume it. Two houses in the same 1930s terrace can carry different coverings, because one was re-roofed in 1988 and the other was not, and the kit follows the covering that is actually on the roof today.

Plain tile: small units, double lap, and a kit that likes them

Plain tiles are the easiest covering to flash well and the least forgiving of sloppy setting out. They are small, laid double lap, and there are a lot of them, so the side soakers meet a new course every 100mm or so up the slope. That gives a flashing plenty of opportunities to be lapped correctly, and plenty to be lapped incorrectly.

The practical points are the cut tiles at the sides of the opening. A plain tile cut to less than about half its width has almost nothing holding it and no nail hole left, so a well-flashed plain tile roof is one where the window position has been nudged sideways to land on a sensible bond. That is not always possible, and where it is not, tile-and-a-half units or clipped cut pieces do the job. What you should not see is a row of slivers bedded in mortar along each side of the frame, which is a repair waiting to happen and one of the things we look for when somebody calls about staining round a skylight fitted by somebody else.

Flashing kits for plain tile, pantile and slate, and where they differ
The flashing kit is chosen for the covering profile, not the window.

Pantiles: the curve is the whole problem

A pantile roof is a series of channels and rolls. Water runs in the channels, and the rolls are simply the high points between them. A profiled flashing kit is designed to be dressed down into the channels along the apron and up over the rolls, and doing that well is craft rather than assembly. The apron has to be worked into every channel so there is no tunnel left under it, because a tunnel under an apron on an exposed slope is an open invitation to wind-driven rain.

Dorset is pantile country, and the profiles are not standardised. Traditional clay pantiles, modern clay reproductions and concrete interlocking tiles of similar appearance all present a different roll height and a different pitch of channel. A kit that dressed beautifully into one Wareham roof can leave a 6mm gap at every channel on a house two streets away. The kit is chosen at survey, against the tile on that roof, and where the profile falls between families we fabricate the apron in lead instead of forcing a pressing to fit.

Slate: flat, thin, and merciless about anything proud

Slate is a flat-covering kit, so the sections are shallow. What slate adds is fragility and a fixing regime that does not tolerate improvisation. Slates are holed and nailed, laid to a head lap that depends on pitch and exposure, and every one around the opening is going to be cut. A cut slate near the frame often loses its nail hole, which means a clip or a copper tingle rather than a nail, and a bedded-in-mortar solution is not one.

The second slate-specific point is the head. Because slates are thin, a head flashing that stands proud even slightly lifts the course above it, and a lifted slate is a slate the wind can work. Done properly, the head flashing goes under the course above and disappears; you should be able to stand back on the pavement and see an uninterrupted slate roof with a window in it, not a metal band across the slope.

Where a catalogue kit stops

The roof no kit is made for

Purbeck stone slate defeats every standard flashing kit on the market. The slates are thick, heavy, irregular in width and laid in diminishing courses, so there is no consistent profile for a pressing to seal against and no consistent course height for a soaker to lap. The answer is lead, cut and dressed on site to the stones that are actually there. It is a different job, priced differently, and we have given it a guide of its own rather than a paragraph here.

The other stop is depth. Very deep profile tiles, some of the older Roman and double Roman patterns among them, exceed the reach of a standard profiled kit. Some manufacturers make a deep-profile version; where they do not, a lead apron with pressed side sections is the honest answer.

Two windows, one kit

Where units sit side by side in the same slope, or stacked one above the other, a combination kit replaces two separate sets. The point of it is the joint: between two side-by-side frames the kit forms a lined gutter running down the rafter between them, and between stacked frames it forms a flashed apron that clears the upper window onto the lower. Two separate single kits pushed close together do not make that gutter, and the space between them becomes a trap that holds debris and eventually water.

Combi kits fix the spacing. The frames must sit a set distance apart, which on a side-by-side pair usually means one standard rafter width plus tolerance. It is a reason to decide on a pair early, because the structural opening is dimensioned for the kit as much as for the windows.

Flashing kits for plain tile, pantile and slate, and where they differ
In the slope of the ceiling, daylight reaches further into the room than a dormer.

Aluminium, lead and zinc, twenty years on

Kit material matters more here than it does forty miles inland. Salt does not merely tarnish a flashing; it drives galvanic corrosion at any point where two dissimilar metals sit together in a damp, chloride-rich film, which is precisely the condition on the windward slope of a roof at the harbour mouth.

Material Behaviour in salt air Where we specify it
Coated aluminium Durable, but a coating breach at a cut edge will pit. Cut edges want sealing Standard across inland and sheltered addresses. Fine almost everywhere with sound detailing
Lead Extremely tolerant of marine exposure. Forms a stable patina and keeps working Bespoke aprons, stone slate, deep profiles, and anywhere a pressing will not fit
Zinc or zinc-coated steel Sacrificial. Fine inland, shorter life in a chloride-laden atmosphere Not our default on the spit or the open coast
Fixings around the kit The usual failure. Plated screws bleed rust down a slate slope in two winters A4 stainless on the spit and the exposed coast; standard grade inland, and we will say so

Inland at Broadstone, Creekmoor or Ferndown, marine-grade everything is an overcharge and we will tell you that rather than bill for it.

The order it goes on

Flashing is a sequence, and the sequence is the waterproofing. Every piece must be lapped by the piece uphill of it, without exception, because water does not care how neat the finished job looks.

  1. Underlay collar first. Dressed onto the roofing membrane and taped to the frame, forming the drainage path beneath everything else.
  2. Battens made good. Cut ends supported, the batten gauge reset around the opening so courses land where the kit expects them.
  3. Apron at the bottom, over the course below. Dressed into every channel on a profiled covering.
  4. Side sections from the bottom upwards. Each one lapped over the one beneath by the stated amount, never butted.
  5. Covering rebuilt course by course as the sides go up. The two proceed together. A flashing fitted after the tiles are back is a flashing sitting on top of the roof rather than in it.
  6. Head flashing last, tucked under the courses above. Then the frame trims clipped on and the whole assembly water tested.

The four leaks we are actually called to

Almost every flashing callout on a roof window is one of four things, and none of them is a failure of the window.

In rough order of frequency

The wrong kit family. A flat-covering kit on pantiles, or a profiled kit on slate. Symptom: water appearing at the head of the reveal in driven rain, dry in vertical rain.

The kit fitted after the covering. Sections sitting over the tiles rather than interleaved. Symptom: staining down one side, worse on the windward side.

No underlay collar. The kit is right and the membrane below it is cut open. Symptom: damp on a rafter a metre away from the window, and a homeowner convinced the roof itself is failing.

Corroded fixings and lifted cut edges. Almost exclusively a coastal problem, almost always plated screws. Symptom: rust streaks, then a loose apron.

If a rooflight or roof window on your roof is staining the reveal and you have been told the unit needs replacing, it is worth having the flashing looked at first. We survey the covering, name the kit family it needs and the exposure zone it sits in, and give you a fixed written price before any work starts. Our installations carry a ten-year workmanship guarantee, not insurance backed, stated plainly because the distinction matters. Ring 01202 923272 and tell us what the roof is covered with; that is the first question we will ask anyway.

Get a fixed quote

Get a fixed quote

Tell us which way your roof faces.

We will come back with a specification, not a catalogue page. If your extension faces south we will tell you the G-value we would fit and why.

  • No pressure, no doorstep sales call
  • We handle the Building Control notification
  • 10-year workmanship guarantee on every installation
  • Installations and replacements across Poole and south Dorset

Prefer to talk it through? 01202 923272