Reflectivity percentages and the light lost at every bend

How to read a declared reflectance figure, why the loss along a tunnel multiplies rather than adds, and what a bend costs that a straight metre does not.

A sun tunnel run from dome to diffuserLight enters at the dome and is reflected down the tube to a ceiling diffuser. Every bend costs reflectance, so a straight short run delivers far more than a long one with turns. Light falls with the square of the diameter.daylightdomeevery bend costs lightceiling diffuser

A reflectivity figure on a sun tunnel data sheet is a real, measured property of the tube wall. What it is not is a number you can multiply by your run length to predict how bright your hallway will be.

This page is about reading those figures honestly: what is actually being measured, why a very high number still leaves a long tunnel dim, what a bend does that a straight metre does not, and which claims should make you ask for the data sheet.

What the figure is measuring

Reflectance is the proportion of the light arriving at a surface that leaves it again rather than being absorbed. It is quoted for the inner wall material of the tube, measured on a sample, under stated conditions, across a stated range of wavelengths.

Two things about that definition matter more than the number itself. First, it describes one bounce. Not the tunnel, not the run, not your ceiling — one encounter between light and the wall. Second, it is a property of the material as tested, which means the figure belongs to the manufacturer who tested it and is published by them. We quote theirs. We do not have our own.

Our rule on numbers, which is a rule about liability as much as accuracy

We do not invent performance figures. Not reflectance percentages, not lumen outputs, not the loss you will see at a given bend, not a rule converting tube diameter into square metres of floor lit. Those are declared by the manufacturer of the specific product against a specific test, and that declaration is what governs.

What we will do is explain the principle so you can read their figures and understand what they imply, and tell you which product we are proposing so you can read the sheet yourself before you commit to anything.

Why a very good number still runs out

The instinct on seeing a high reflectance figure is that a few percent lost per bounce is nothing. The arithmetic does not work that way, because the losses are not subtracted once. They multiply.

Each bounce takes its cut of whatever is left, not of what started. Light that has already lost a little at bounce one loses a fraction of the remainder at bounce two, and a fraction of that remainder at bounce three. A small per-bounce loss and a large number of bounces produce a result that surprises people who expected the decline to be gentle and straight.

So the useful question is never just “how reflective is it”. It is “how reflective, over how many bounces”. And the bounce count is set by things the data sheet cannot know about: how long your run is, how wide the tube is, how steeply the light entered, and how many times it had to change direction.

What sets the bounce count

Factor Effect on the number of bounces What you can do about it
Run length More distance, more encounters with the wall Move one end. A shorter run is the single most effective change
Tube diameter A wider tube lets light travel further between bounces Specify up a size where the void and ceiling allow
Angle the light enters at Steep low-sun light bounces far more than overhead light Nothing. It is why winter and summer feel different
Wall smoothness Corrugations scatter, multiplying encounters per metre Rigid tube where the route allows it
Each change of direction Concentrates extra bounces into a short length Fewer and shallower turns, planned at survey

What a bend actually does

A straight tube lets a beam travel a long way between wall contacts. Light entering near the axis can cross several metres with very few encounters. That is the best case, and a straight vertical drop is the best case for a reason.

Put a turn in and the geometry changes. The far wall of the bend arrives sooner than it would have done, so light that was travelling in long strides gets intercepted early. Worse, it is intercepted at a steeper angle, and steep encounters are less efficient than grazing ones. After the bend the beam carries on at a new angle, which means the rest of the run behaves as though the light entered it badly.

That is why a bend is not equivalent to some extra metres of straight tube. It changes the character of everything downstream of it, not just the short section it occupies.

Reflectivity percentages and the light lost at every bend
A prepared kerb, squared and weatherproofed, before the unit goes on.

Angle matters as much as count

Two bends are not automatically twice as bad as one, and one sharp bend can be worse than two gentle ones. What costs is deflection: how far the light has to be turned from the direction it was going.

  1. A shallow offset. Two small deflections in opposite directions to step the tube sideways past a joist. The light is turned a little, then turned back. Cheap, in light terms.
  2. One right-angle turn. The whole beam is redirected. Everything downstream is now entering at angles it would not have chosen. Expensive.
  3. A turn immediately under the dome. Worse again, because it happens before the light has spread out along the tube, so more of it meets the bend at once.
  4. A turn just above the diffuser. Costly in a different way — it scrambles the distribution right at the end, which shows up as an uneven pool of light rather than a dim one.

Why nobody can compute your result on paper

People occasionally ask for the sum: take the declared reflectance, raise it to the power of the estimated bounce count, apply it to the light available, and predict the lux at the floor. It can be modelled, and manufacturers do model it, which is why their published performance data exists and is worth reading.

What cannot be done honestly is an installer performing that calculation on the phone from a postcode. The inputs are not known until someone has been in your loft: the true run, the real angle of the roof plane, what the dome can see past a chimney or a neighbouring gable, the diameter the ceiling will take, and how many degrees of deflection the route demands. Change any one and the answer moves.

What the pine canopy does to all of this

Canford Cliffs and Branksome Park

Every figure discussed here describes what happens to light after it enters the dome. Under a mature pine canopy, the problem starts earlier: less light reaches the dome at all, and evergreen shade does not lift in winter the way a deciduous canopy does.

A tunnel under those trees is being asked to deliver a share of a smaller starting amount, and the needles settling on a small dome take another share before anything gets in. The highest reflectance tube on the market cannot return light that never arrived. Where canopy is heavy, the honest specification conversation is often about a rooflight on a clear part of the roof, or about accepting that the room needs an electric answer as well.

Reflectivity percentages and the light lost at every bend
Daylight into a bathroom with no outside wall to put a window in.

Reading a data sheet without being sold to

When you have a product proposal in front of you, four things on the sheet are worth finding. The declared reflectance and the wavelength range it covers. The maximum run the maker will stand behind for that diameter. Their published output data, and the configuration it assumes — almost always a straight run, which yours will not be. And the warranty, particularly whether the reflective surface is covered and for how long.

A sheet that quotes reflectance but publishes no maximum run is telling you less than it appears to. So is a headline figure with no test standard next to it.

What we do with the figures in practice

We use them comparatively rather than predictively. Between two products that will both physically fit your route, the declared figures and declared maximum runs tell us which will hold up better over the distance your loft actually imposes. That is a decision the numbers can support.

What the numbers cannot do is promise you a feeling. Whether a hallway reads as daylit or merely not-dark depends on the wall colours, the floor, what else opens off it and what you are comparing it with. We describe what the tunnel will do in plain terms at survey, and we would rather undersell it than have you measure the result against a figure nobody should have given you.

If the room in question has a roof plane of its own and would take a skylight, we will say so — a rooflight there beats a tunnel on every one of these numbers, and recommending the smaller product when the bigger one suits is not a service to anyone. Ring 01202 923272 and we will walk the route before we specify anything.

Get a fixed quote

Get a fixed quote

Tell us which way your roof faces.

We will come back with a specification, not a catalogue page. If your extension faces south we will tell you the G-value we would fit and why.

  • No pressure, no doorstep sales call
  • We handle the Building Control notification
  • 10-year workmanship guarantee on every installation
  • Installations and replacements across Poole and south Dorset

Prefer to talk it through? 01202 923272