Insulation depth at the kerb and the cold line you cannot see

Where the thermal line runs around a flat rooflight kerb, how deep the insulation has to be, and the two joints where continuity is usually broken.

Section through a rooflight kerb on a flat roofThe unit sits on an insulated kerb standing proud of the finished roof surface. The covering is dressed up the kerb face and terminated under the frame, so water meeting the kerb runs away down the fall rather than under the unit.glazed unitinsulated kerbcovering dressed up the facedeck and insulationfallwater runs away, not under

The drip that is not a leak

A fair number of the calls we take about a flat roof rooflight are not about leaks at all. The description is nearly always the same: water running down the inside of the reveal, or a dark line on the plasterboard at one corner, appearing on cold mornings and drying up by lunchtime, with no rain in the forecast at any point.

That is condensation, and it is telling you something precise. Somewhere in the ring of construction around your skylight there is a surface cold enough for room air to give up its moisture when it touches. The glass is rarely the culprit on a modern unit. The kerb almost always is, and specifically the depth of insulation on it and whether that insulation actually meets the frame.

This is the part of the detail nobody can see once the job is finished, which is exactly why it is worth understanding before it is covered up.

Where the cold line runs in three deck types

“The cold line” is shorthand for the plane where the insulation sits. Everything on the warm side of it stays close to room temperature; everything on the outside of it follows the weather. A rooflight kerb is a 150mm or taller obstruction standing right where that plane has to turn a corner, and the three common flat roof build-ups turn it differently.

Build-up Where the insulation sits What has to happen at the kerb The failure it produces when it is not done
Warm deck Above the structural deck, below the covering Insulation carries up the outside face of the kerb, continuous to the frame A cold timber ring right at the ceiling line, condensing on its inside face
Cold deck Between the joists, with a ventilated void above it Insulation returns up the inside of the kerb, and the void must still ventilate past the new opening Damp joist ends and rot around a rooflight that has never let in a drop
Inverted (ballasted) Above the waterproofing, under ballast or paving Insulation butts tight to the kerb and the effective kerb height is measured from the top of the ballast A short upstand plus a cold gap at the base of the kerb
Old bituminous over boards Frequently nowhere at all A decision about whether to insulate the roof while it is open A new warm room under an uninsulated roof, with the new unit blamed for the result

Depth is the number, presence is not

Almost every kerb we open up has some insulation on it. Far fewer have enough, and fewer still have it in the right place. A 25mm strip of rigid board tacked to the outside of a timber upstand satisfies the word “insulated” on a specification and does very little to the temperature of the inside face, because the timber it is fixed to is 150mm deep and conducting heat out along its whole height.

The working target is straightforward to state and slightly awkward to achieve: the thermal resistance going through the kerb should be in the same league as the thermal resistance going through the roof beside it. If the flat roof has 120mm of rigid insulation and the kerb has 25mm, you have built a deliberate weak spot into the one part of the roof that is nearest to the room and most exposed to warm, moist air rising into it.

Continuity, and the two places it is usually broken

The rule, and the two joints that break it

The rule: the insulation line must run from the roof, up the kerb, and arrive at the rooflight frame without a break. Not “up to near the frame”. To it.

Break one — the top 30mm. Insulation is taken up the kerb and then stopped short so the covering, the fixing flange and the frame have somewhere to sit. That last strip of bare timber or bare metal is a continuous cold path around the entire perimeter, and it is exactly where the condensation appears. The fix is a designed termination — the insulation carried to the underside of the frame, with the frame’s own thermal break aligned to it — not a bead of sealant.

Break two — the base of the kerb. Where the kerb meets the deck, the roof insulation has to be cut to fit around it. Cut generously and you leave an air gap; cut tight and awkwardly and you leave a triangular void at every corner. Corners are where condensation starts, every time, because they lose heat in two directions at once.

Insulation depth at the kerb and the cold line you cannot see
A prepared kerb, squared and weatherproofed, before the unit goes on.

The vapour control layer is the other half of the job

Insulation controls how cold the surface gets. The vapour control layer controls how much moisture reaches the cold surface in the first place, and on a warm deck roof it sits under the insulation, on the warm side. At a rooflight it has to be turned up the inside of the kerb and sealed to the frame, so that the moist air in your kitchen or bathroom cannot simply track up behind the plasterboard and condense inside the construction where nobody will see it for six years.

This is the detail most often skipped, because it is invisible, it is fiddly at corners, and nothing appears to go wrong on handover day. What goes wrong later is interstitial condensation: damp insulation, which insulates worse, which makes the surface colder, which condenses more. It is a loop that does not stop on its own.

How we build the detail

  1. Establish the existing build-up first. Warm, cold or inverted, and the actual insulation thickness — measured, not assumed from the age of the extension.
  2. Set the kerb height against the finished surface, including any ballast or paving, so the thermal detail and the weathering detail are designed off the same datum.
  3. Turn the vapour control layer up the kerb and tape it, before insulation goes anywhere near it, with the corners formed rather than folded.
  4. Insulate the kerb to a depth that matches the roof, using a board that can be cut cleanly at corners, and butt every joint.
  5. Terminate at the frame, not near it, so the insulation line and the frame’s thermal break are continuous with one another.
  6. Keep the ventilation path open on a cold deck — all four sides of the new opening, past the kerb, not boxed in by it.
  7. Photograph it before the covering goes on. It is the only record anyone will ever have of the part of your roof that cannot be inspected again.

What the unit itself contributes

A glazed unit carries two different figures and they get confused constantly. The centre-pane figure describes the glass in the middle, away from every edge. The whole-unit figure includes the frame, the spacer and the edge of the glass, and it is always the worse of the two — which is the honest number, because your ceiling is attached to the edge, not to the middle of the pane.

A warm-edge spacer bar and a genuine thermal break in the frame both move that whole-unit figure, and both are worth asking about. But neither of them will rescue a kerb that has been left thin. The unit is one ring of construction; the kerb is the ring around it; and the room sees whichever of the two is coldest.

Insulation depth at the kerb and the cold line you cannot see
The frame-to-membrane junction, which is where flat roofs are won or lost.

Why this matters more in some parts of Poole than others

Marine air is damp air. On the harbour shore and out towards the spit, relative humidity runs high for long stretches of the autumn and winter, so the temperature at which a surface starts collecting water is closer to room temperature than it is inland. The same kerb detail that is merely mediocre in Wimborne will produce visible condensation in Hamworthy. Inland has its own version of the problem: the low ground around Creekmoor and the heathland hollows hold cold air overnight, which drives the outside face colder than the general forecast suggests. Different mechanism, same wet reveal.

Reading a rooflight that is already doing it

What you see What it usually means What it takes to put right
Water on the inside of the glass only, clearing by midday Normal surface condensation in a humid room, not a construction fault Ventilation and moisture control in the room below
Water along the frame edge, glass clear Cold bridge at the frame-to-kerb junction Opening up the head of the kerb and terminating the insulation properly
Dark corners on the plasterboard reveal Voids in the kerb insulation at the corners Reveal off, insulation reinstated continuous, board reinstated
Mould on the reveal, nothing on the glass The construction is colder than the glazing — the kerb is the weak ring A kerb upgrade, which is roof work rather than glazing work
Misting inside the sealed unit The unit’s own seal has failed and is nothing to do with the kerb Replacement glazing — a separate job, covered elsewhere on this site

What we will commit to

Stated plainly

A fixed written price after survey that names the kerb insulation depth and the vapour control detail as line items, rather than folding them into a single figure for a skylight fitted.

A ten-year workmanship guarantee covering our installation, not insurance backed, stated here rather than in small print.

Photographs of the thermal detail before it is covered, handed over with the job, because you are entitled to see the part of the roof you are paying for and will never be able to look at again.

If a rooflight you already have is wetting its reveal every cold morning, that is a diagnosable fault with a known cause. Ring 01202 923272 and describe where the water appears — frame, glass or plasterboard — because that one detail narrows it down before anyone visits.

Get a fixed quote

Get a fixed quote

Tell us which way your roof faces.

We will come back with a specification, not a catalogue page. If your extension faces south we will tell you the G-value we would fit and why.

  • No pressure, no doorstep sales call
  • We handle the Building Control notification
  • 10-year workmanship guarantee on every installation
  • Installations and replacements across Poole and south Dorset

Prefer to talk it through? 01202 923272