Rooflight and skylight installation in Alderney, where the specification argument is not coatings but whether the unit opens, how it is operated and what the ventilation guidance expects.

ZoneSpecified by exposure
10 yrWorkmanship guarantee
BCPNotification handled
Roofs and exposure around Rooflight and Skylight Installation Alderney
Four miles inland the same roof is an ordinary one, and marine-grade is an overcharge.
Roofs and exposure around Rooflight and Skylight Installation Alderney
Four miles inland the same roof is an ordinary one, and marine-grade is an overcharge.
Exposure zones across the Poole service areaExposure changes within about four miles. The harbour mouth and the spit take salt-laden wind with no fetch break; the Quay and Old Town are sheltered by the land behind them; the wooded cliffs add debris and canopy; inland is ordinary exposure where a marine specification is an overcharge.spitharbourwooded cliffinlandmost aggressiveordinaryabout four miles changes the specification

The Alderney question is not what it is made of. It is whether it opens

Most of the calls we take from Alderney are about ordinary post-war and later estate houses on ordinary inland roofs, and the specification arguments that dominate our coastal pages simply do not arise. What does arise, over and over, is the decision people skip: fixed or opening, and if opening, how it is going to be operated by an actual person standing in the actual room.

It gets skipped because it sounds like a preference rather than a specification. It is not. It is the choice that decides whether the room complies with the ventilation guidance, whether the bathroom stops steaming up, whether anyone can reach the handle, and whether the skylight you paid for is still being opened in year three or has quietly become a fixed light that somebody once paid extra for.

The exposure section on this page is one sentence long, and that is the honest length. Alderney is inland, on the Poole and Bournemouth boundary with the built-up area between it and the sea, so we write standard architectural coatings and standard fixings on the quotation and there is no marine build-up to discuss. The open heath at Turbary Common next door gives some roofs here a genuinely open aspect on one side, which is a wind and debris note rather than a corrosion one — it affects fixing centres and how often a drainage channel needs clearing, not the finish on the frame.

Fixed, opening, and what each is actually for

Type What it is good at What it costs you
Fixed light Pure daylight. Fewer moving parts, a simpler seal line, and generally more glass for the money at any given size No ventilation at all, and it can never contribute to purge ventilation or to escape from a loft room
Manually opening roof window Daylight plus ventilation, with no power and nothing to go wrong electrically Somebody has to be able to reach it. If it is out of reach it will be opened twice a year
Pole-operated High units in a stairwell, a landing or a double-height space, at very little extra cost A pole that has to live somewhere, and an operation nobody does casually while cooking
Electric, with a rain sensor Anything out of reach, and anything you want to leave open in changeable weather — the sensor shuts it when rain starts A power supply to the unit, which is far cheaper to run in while the opening is being formed than to add afterwards
Solar-powered electric The same benefits where getting a cable to the position would mean lifting a finished ceiling A battery and a small panel on the frame, and a slightly higher unit price for a much lower installation cost

The point of the table is the last column. There is no best answer, but there is a wrong one for each room, and the wrong one is almost always chosen by deciding on the glass first and the operation last.

What Building Control is actually looking for

Ventilation, in the terms the guidance uses

Background ventilation is the small, continuous airflow that stops moisture building up — in practice, trickle ventilators. Current guidance expects that when you replace a window or a rooflight you do not leave the room with less background ventilation than it had, which in most replacements means specifying a unit with trickle ventilation in it. That is a specification decision made at order, not a fitting decision made on the day.

Purge ventilation is the big, occasional airflow that clears cooking, steam or paint fumes. The guidance route for it is an openable area of roughly one twentieth of the room’s floor area, and an opening rooflight counts towards it. A fixed light contributes nothing, which is why a room whose only opening light is being replaced with a fixed unit needs thinking about rather than assuming.

What we do: we tell you which of these your room is relying on before the unit is ordered, and Building Control for the work goes through BCP Council or an approved inspector either way.

Reach, and the handle nobody can get to

A roof window in a pitched slope is further away than it looks. The cill may be 1.1 metres from the floor, but the head of the unit can easily be 2.4 metres away measured along the line of the slope, and if there is a bed, a bath or a worktop beneath it, the distance that matters is not the one on the drawing.

Ranges differ in a way that is worth knowing before you choose. Some put the operating bar at the top of the sash precisely so it can be reached from standing height without leaning across whatever is underneath; others put the handle at the bottom, which is easier when the unit is low and awkward when it is high. Neither is better. They suit different positions, and the position is decided by the roof, so the sensible order is to fix the position, then pick the operation, then pick the glass. We survey with a tape measure and a standing adult rather than a specification sheet.

A rooflight is not an extractor fan

This is the correction we make most often in bathrooms and kitchens. An opening rooflight above a shower does a lot of good, but it does not remove the requirement for mechanical extract in a room that generates moisture, and it will not on its own keep a small internal bathroom dry through a Dorset winter. Steam rises to the highest point in the room and condenses on the coldest surface it finds, and if that surface is the glass and the reveal of a new skylight, you have installed the thing the moisture now collects on. The answer is a properly sized extract fan, an insulated reveal, and a unit whose opening is used — which brings you straight back to whether anyone can reach it.

The summer version of the same problem

A room under a roof gets hot, and in an estate house with a converted loft or a south-facing rear extension that is the complaint we hear from July onwards. Ventilation is half of the fix and it works better than people expect, provided the geometry is right.

Warm air collects at the highest point in a room, so an opening rooflight at the top of a space and any window low down on the opposite side will move air through it without a fan doing anything. Open both and the room empties its heat in the evening. Open only the rooflight and very little happens, because there is nowhere for replacement air to come in. That is why we ask what other openings the room has before recommending an opening unit — and why, in a room with no low-level window at all, the honest answer is often that the glass specification has to do more of the work and a solar control unit is worth the money.

Room by room, what the unit is being asked to do

Room What it actually needs What we would normally specify
Kitchen or kitchen-diner Purge ventilation for cooking, and a handle somebody can reach with their hands full Opening unit, positioned away from over the hob, with electric operation if it sits above a run of units
Bathroom or shower room Moisture removal, which is mostly the extract fan’s job rather than the window’s Opening unit with obscure or laminated glass, an insulated reveal, and plain advice about the fan even though it is not our work
Bedroom in a converted loft Night ventilation without noise, and in some conversions a compliant escape opening Opening unit sized and positioned to the Building Control requirement, with the escape question settled before the order
Landing or stairwell Daylight, and a way of dumping hot air out of the top of the house in summer High unit with pole or electric operation — the one position where a manual handle is almost always the wrong choice
Converted garage or home office Cross-ventilation, because these rooms usually have one window and no through-draught at all Opening unit at the high point, and an honest conversation about whether the room also needs solar control glass

What the structure permits is a separate question from what the room needs, and the two have to meet somewhere. Whether your roof is a cut one or a trussed one sets the maximum width before any of this applies; that argument is made in full on the Kinson page rather than repeated here.

How the job runs

  1. The room first. What it is used for, what openings it already has, what generates moisture in it, and who has to be able to reach the handle.
  2. Roof void inspected, structure identified and centres measured, and any cable route for an electric unit identified while it is still easy.
  3. Operation chosen, then the glass. Fixed, manual, pole or electric — decided from the position rather than from a price list.
  4. Ventilation settled. Trickle ventilation on a replacement, purge ventilation checked against the room, and any extract requirement stated plainly even where it is not our work.
  5. Building Control notified, through BCP Council or an approved inspector, with the ventilation position stated rather than left to the inspection.
  6. Fixed written price after survey, itemised, with any electrical work shown separately.
  7. Opening formed and weathered, reveal insulated and lined, unit hose tested and the operation demonstrated to whoever will be using it.

The two things we will put our name to

And nothing else, because there is nothing else

A ten-year workmanship guarantee on our installation. Not insurance backed, said here rather than in a footnote. Electrical components, glazing and frames carry their manufacturers’ own warranties, handed over at completion.

A fixed written price after survey. From a measured roof and a walked room. If something unforeseeable appears once the covering is off, we stop, show you and price the remedy separately.

We install and replace rooflights, skylights, roof windows and lanterns across Alderney and about thirty miles around Poole, and we do not take general roofing work. If you already know roughly where you want a skylight and have not yet thought about how you will open it, ring 01202 923272 and start there instead — it is the decision that is hardest to change afterwards.

Get a fixed quote

Tell us which way your roof faces.

We will come back with a specification, not a catalogue page. If your extension faces south we will tell you the G-value we would fit and why.

  • No pressure, no doorstep sales call
  • We handle the Building Control notification
  • 10-year workmanship guarantee on every installation
  • Installations and replacements across Poole and south Dorset

Prefer to talk it through? 01202 923272