How a rain sensor decides to close, and when it gets that wrong

A rain sensor is a resistance measurement with a timer attached, and understanding that explains both what it saves you from and the three things it cannot do.

An opening rooflight and the parts that move itA chain or spindle actuator drives the sash open against its hinges. The cable is routed to the kerb before the ceiling closes, because reaching it afterwards means opening the ceiling. An open sash on an exposed roof is a sail, which is what wind sensors and restrictors answer.sashactuatorhingecable routed before the ceiling closeswind load on an open sash

A rain sensor is not a weather forecast. It is a pair of conductive tracks, a threshold and a timer, and every one of its useful behaviours and every one of its irritating ones falls out of that.

Nearly every opening rooflight sold in Dorset comes with one, or the option of one, and almost nobody explains what it does. Owners then discover the limits in the worst way: a wet windowsill, or a skylight that has decided never to open again. This guide follows the decision from the first drop to the closed sash.

The decision, step by step

  1. Water lands on the pad. Two interleaved conductive tracks sit a hair apart on the external face of the frame or an adjacent bracket. Dry, nothing passes between them.
  2. Resistance falls. Water bridges the tracks. Rainwater conducts poorly, but it conducts, and the controller sees the resistance drop.
  3. The threshold is crossed. The controller compares that reading against a set point. Below it, the pad counts as wet. Above it, it does not.
  4. A close command is issued. On most controllers this is immediate. On some there is a short confirmation delay to ignore a single splash.
  5. The sash travels. This is not instant. A drive moves at a deliberate, safe speed and a wide opening takes the best part of half a minute to come back.
  6. A dwell timer starts. The unit is held closed while the pad stays wet and for a set period after it dries, so a shower does not produce a sash flapping open and shut.
  7. Nothing else happens. On most domestic controllers the rooflight stays shut until a person asks for it again.

The pad measures conductivity, not rainfall

That distinction explains nearly every complaint. A rain gauge measures volume. A sensor pad measures whether something conductive is lying across two tracks. Anything conductive will do, and how much of it there is barely matters.

Some pads are heated, which is a genuinely useful refinement: gentle warmth evaporates the film after the shower passes so the unit releases sooner, and it discourages the standing dampness that otherwise keeps a skylight locked shut all morning. Many have an adjustable sensitivity, set at commissioning rather than left where the factory put it.

What none of them have is any notion of what is coming. The pad cannot see the squall crossing the harbour. It responds after the first water arrives, which is the whole basis of the next section.

The interval nobody quotes

Add the links together and the honest figure is not “it closes when it rains” but a few seconds of detection plus any confirmation delay plus the travel time. On a large sash at a wide opening angle, in wind driving the rain sideways, that interval is long enough for water to reach a sill.

What this means for where the water goes

A rain sensor is protection against a soaking, not a guarantee of a dry floor. If the room below has something that must never get wet — a piano, a stair carpet, an untreated timber floor — the design answer is a restricted opening angle or a position that throws run-off clear, decided at survey. The sensor is the backstop, not the plan.

The false positives, and which ones matter here

What triggers it Why the pad reads wet How it shows up
Heavy dew on a clear night Condensate bridges the tracks as effectively as rain The rooflight shuts itself around dawn on the driest week of the year
Sea mist off the harbour Fine droplets settle and, being salty, conduct far better than rain Closes in weather nobody would call rain
A salt film left after drying Dry salt is hygroscopic and pulls moisture out of humid air Reads wet permanently, so the unit refuses to open at all
Pine resin and needle litter A sticky film holds damp against the tracks Slow to release after rain, then eventually stuck
Gull droppings Conductive and stubborn, and gulls favour the highest point Abrupt, total, and obvious once you look
Garden sprinkler or a hose It is water Closes while you are washing the car

The third row is the one that turns into a callout. A pad that has dried out after salt spray is not clean: the salt stays, and on a humid morning it draws enough moisture from the air to conduct. The owner reports a dead motor. The motor is fine and the controller is refusing to open a unit it believes is standing in the rain.

How a rain sensor decides to close, and when it gets that wrong
A chain actuator suits a light sash; a spindle drive suits a heavy one.

The false negatives, which are quieter

These get noticed less because nothing visibly misbehaves. Very light drizzle can sit below the threshold, especially on a sensitivity left at a low factory setting. A pad mounted in the lee of a parapet or an upstand can stay dry while rain reaches the opening from the other side. And on a windy day the rain reaches the aperture before it reaches a pad sited a little away from it.

A pad also cannot tell the difference between rain and the run-off from its own sash. Site it where water shed from the closing leaf runs across it and the unit holds itself shut long after the sky cleared, because it keeps re-wetting its own sensor.

Siting: the decision that makes or breaks it

Position is worth more than sensitivity settings. Four rules cover almost every roof around Poole.

  1. In the weather, not in a shadow. Exposed to the same rain the aperture is, without an upstand or parapet sheltering it.
  2. Out of the run-off path. Not where water from the sash, the glazing or an adjacent slope will cross it after the rain has stopped.
  3. Off the debris line. Under a canopy in Canford Cliffs or Branksome Park, away from where needles collect, and never in a drainage channel.
  4. Reachable. If it cannot be wiped from a tower or a window without scaffolding, it will not be wiped, and an unwiped pad is a fault waiting to happen.

Most units do not reopen, and that surprises people

The natural assumption is that a rain sensor manages ventilation — shuts for the shower, opens again after. Very few domestic controllers work that way. The close is automatic; the reopen is a human being pressing a switch.

There is sense in it. A controller that reopened on its own would reopen while the house was empty, or overnight, or into a gust. Where automatic reopening exists it is usually part of a wider control scheme with wind and temperature inputs, which is a different specification and a different conversation.

On the spit it is deliberate. At Sandbanks, Studland and Mudeford an open sash is a sail, and the wind that drives rain onto a pad is the same wind loading the hinge. Automatic reopening is the last thing those roofs want, which is why units there are commissioned to close on rain, stay closed, and reopen only when someone decides.

How a rain sensor decides to close, and when it gets that wrong
Left open on a still evening to purge the day's heat.

Sea mist, salt and the harbour specifically

Yes, sea mist will close a rooflight, and near the water it does so often enough that people ask about it before they ask about anything else. Salt in the droplets makes them better conductors than rainwater, so a haze that leaves nothing on a windscreen can be plenty for a sensor pad.

That is a separate question with its own answer, covered in whether rain sensors react to sea mist. What belongs here is the design consequence: on a harbour-side or spit roof the pad wants siting and cleaning as a maintenance item from day one, not as a discovery in year three.

Cleaning a pad without wrecking it

Fresh water, a soft cloth, light pressure. That is the whole method, two or three times a year inland and rather more often near the water. The point of fresh water is to dissolve and carry away salt rather than smear it around, so a rinse first and a wipe second.

What not to do: no solvents, no abrasive pads, no wire wool on the tracks, and above all no pressure washer anywhere near an opening skylight. A pressure washer drives water past gaskets that were designed to shed it, not to resist a jet, and it will strip a sensor pad’s surface. We have yet to see a rooflight improved by one.

What we set, and what we tell you it cannot do

At commissioning the pad gets wetted by hand and the whole sequence watched: detection, the close command, the travel, the dwell. The sensitivity is set for the exposure rather than left at default, the position is checked against the four rules above, and the time from wet pad to closed sash is measured on your unit and written on the handover sheet.

The three sentences we say out loud at handover

It reacts, it does not predict. There will be water in the air before there is a close command.

It does nothing without power. In an outage the sensor is as dead as the motor, so an open sash stays open.

It will not reopen the skylight. That is a person, at a switch, deciding the weather has passed.

A rain sensor is a good thing to have and a poor thing to rely on, and any firm telling you otherwise is selling you the pad rather than the installation. For a survey that settles pad position before the unit is ordered, ring 01202 923272.

Get a fixed quote

Get a fixed quote

Tell us which way your roof faces.

We will come back with a specification, not a catalogue page. If your extension faces south we will tell you the G-value we would fit and why.

  • No pressure, no doorstep sales call
  • We handle the Building Control notification
  • 10-year workmanship guarantee on every installation
  • Installations and replacements across Poole and south Dorset