Matching a new VELUX to an old one when the code has been dropped

When a size code no longer exists in the current grid the decision moves from ordering to carpentry, and the options are governed by rafter centres rather than by the catalogue.

A roof window set between rafters in a pitched coveringThe window sits in the plane of the covering between existing rafters. A flashing kit matched to the covering carries water around the frame, and the underlay is dressed to a collar so anything passing the tiles is returned to the outside.roof windowrafterrafterflashing kitcovering

Most old size codes are still made. A minority are not, and when you are holding one of those the question stops being which unit to order and becomes what to do to the hole.

This comes up on two kinds of roof in our area. Houses where the loft was converted in the 1970s or early 1980s, before the current size grid settled down, and houses where a much older unit carries a code that simply never existed in the modern range. Both are common enough across the Poole and Bournemouth suburbs that we see one most months.

Which codes have actually gone

The familiar widths and heights have been remarkably stable, which is why like-for-like replacement is usually straightforward and why our guide on reading a size code is worth having open. What has disappeared is at the edges: a handful of intermediate sizes that never sold, some very tall units, and the pre-grid codes from the era when the numbering worked differently.

The trap is a code that looks current but is not. Four characters, the right shape, a letter and two digits, and yet no such unit exists today. That is why we will not quote from a photograph of a plate alone when the code is unfamiliar. We check it against the current range first.

Measure the opening, not the window

  1. Work from inside, with the sash rotated and locked, so you are measuring the structural opening rather than the lining.
  2. Take the width between the trimmers at three points: top, middle and bottom. On a settled roof these will not agree, and the smallest one governs.
  3. Take the height up the slope between the head and sill trimmers, again at both sides.
  4. Measure the diagonals. A difference of more than a few millimetres tells you the opening is out of square, which changes the job.
  5. Note the rafter centres either side of the opening, and whether a rafter has been cut and trimmed or the opening sits neatly between two.
  6. Note the roof pitch and the covering, because those decide the flashing whatever size goes in.
  7. Photograph the opening corners from inside, and the window from outside with the surrounding courses visible.

That list is the whole of the diagnostic work. Everything after it is a decision, and the decision is almost entirely constrained by what the roof structure will let you do.

Three ways out of a dropped size

Route What happens to the opening What it costs you When it is the right call
Nearest smaller size, opening packed in New trimmers or packers brought in to reduce the opening to the new frame Slightly less glass, and internal lining to make good all round Most of the time. It is carpentry, not structure, and it is reversible
Nearest larger size, opening enlarged Trimmers moved, and possibly a rafter cut and re-trimmed Structural work, more disruption inside, more covering disturbed outside When the smaller size would leave the room visibly darker, or when the larger size happens to land on rafter centres
A different manufacturer Nothing, if another maker’s standard size matches the old opening A unit that will not match a neighbouring window in profile or finish A single isolated skylight where appearance next to another unit is not an issue

There is a fourth route people ask about, which is a made-to-measure unit. For a genuinely bespoke rooflight that is a real option and we fit them; for a branded roof window with a proprietary flashing system it generally is not, because the flashing is made to the size grid and a bespoke frame leaves you without a matched kit.

Rafter centres are the hard constraint

The width you can have is set by the rafters, not by the catalogue. A window that fits between two rafters needs no structural work at all. A window that requires a rafter to be cut needs trimmers above and below it to carry the load into the neighbouring rafters, and on a modern trussed roof cutting a member is not a decision an installer takes unaided. That single distinction is usually what separates a straightforward replacement from a structural one, and it is decided by measurement before any size is chosen.

Matching a new VELUX to an old one when the code has been dropped
The centre pivot is what lets the outer face be cleaned from inside.

Matching a pair, when only one has failed

This is the awkward case, and it is common on 1970s and 1980s conversions where two or three units went in together. One has misted or the timber has gone, the others are fine, and the size is no longer made.

Three honest positions, and we will give you all three

Replace one and accept the mismatch. Cheapest now. On a rear slope facing a garden, frequently nobody will ever notice. On a front elevation in a conservation area it can look wrong enough to matter.

Replace one and resize the opening to match the others’ visual line. Sometimes the new unit can be set so the glass line reads consistently even though the frames differ. Worth exploring before spending on the third option.

Replace all of them together. More now, less over ten years, because the survivors are the same age as the failure and a second visit costs a second set of access and a second set of disturbed tiles. On brittle clay pantiles that second disturbance is the real expense.

What changes inside the room

A resized opening always shows internally. The plasterboard reveal is cut to the old frame, and a smaller frame leaves a gap while a larger one eats into the existing lining. Neither is difficult, but both mean plastering, drying time and decoration, and that belongs on the quote rather than appearing as a surprise.

The other internal change people forget is the blind. A blind sized to a discontinued code will not transfer to whatever goes in. That question is dealt with on its own answer page; the point here is simply to price it in at the outset.

A resized opening is a decorating job as well as a roofing one. Plaster needs to dry before it takes paint, and on a north-facing loft room in winter that is days rather than hours. If the room has to be usable by a fixed date, that drying time is the constraint to plan around, not the roof work.

When a different manufacturer is the cleaner answer

We are independent and hold no accreditation, approval or partner status with VELUX or any other maker, which means we can say this plainly: if another manufacturer’s standard size drops straight into your existing opening and the branded one does not, that is often the better job. No structural work, no lining to rebuild, no second visit.

The counter-arguments are matching a neighbouring unit, and availability of spares in fifteen years. Both are real. Neither is automatic. We will set out what each route means for your specific roof and let you choose.

Matching a new VELUX to an old one when the code has been dropped
The kerb is measured before anything is ordered.

Building control, and a changed opening

Replacing a roof window is controlled work regardless of the size, and a current unit will comfortably meet the thermal standard that the one coming out never did. Where an opening is enlarged, or a structural member is cut and trimmed, that is a further matter and it is dealt with properly rather than quietly.

Where the house is in a conservation area, or in the Dorset National Landscape, or within the Purbeck heritage constraint, a change in the size or position of an opening on a visible elevation may also need consent. Which authority decides depends on where you are: BCP Council across Poole, Bournemouth and Christchurch, Dorset Council for Wareham, Swanage, Corfe Castle and Wimborne, New Forest District Council over the Hampshire border. Consent is assessed on merit and is never something we would promise you.

What we need before we can answer

Send us these six things and we can answer without a visit

The code from the data plate, if there is one, photographed square on rather than transcribed.

Three width measurements across the opening, at top, middle and bottom.

Two height measurements up the slope, at each side.

The two diagonals, which is how we find out whether the opening is square.

The rafter positions either side of the opening, and whether one has been cut.

A photograph from outside, from the garden, showing the skylight in its courses of tile or slate.

With that we can tell you whether the size still exists, and if it does not, which of the three routes your roof will actually allow. It is rarely a close call once the measurements are in front of us.

Call 01202 923272, or send the measurements to 447880284133 on WhatsApp. We work across Poole, Bournemouth, Christchurch, the Purbeck area and into the New Forest, and our workmanship carries a ten-year guarantee given directly by us, not insurance backed, on a price fixed in writing after survey.

Get a fixed quote

Get a fixed quote

Tell us which way your roof faces.

We will come back with a specification, not a catalogue page. If your extension faces south we will tell you the G-value we would fit and why.

  • No pressure, no doorstep sales call
  • We handle the Building Control notification
  • 10-year workmanship guarantee on every installation
  • Installations and replacements across Poole and south Dorset

Prefer to talk it through? 01202 923272