VELUX Window Installation in Poole

VELUX roof window installation and replacement in Poole — reading the data plate, obsolete size codes, the right flashing kit for your covering, and the ironmongery specification your exposure zone calls for.

ZoneSpecified by exposure
10 yrWorkmanship guarantee
BCPNotification handled
VELUX Window Installation in Poole in Poole
A loft room with the sash open. Size codes and flashing kits come off the data plate.

VELUX is a brand name, not a type of window

People say “a VELUX” the way they say “a Hoover”. Usually harmless; here it is not. A roof window sits in the plane of a pitched roof, between the rafters, with the tiles or slates dressed up to it, and several makers build one. VELUX is a particular Danish manufacturer whose windows carry their own size codes, flashing kits and spare parts — so if you have one, those codes are the shortest route to a replacement that fits.

It is not a flat rooflight on a kerb, nor a lantern standing proud of one: a roof window lies in the slope itself.

What we are not, said plainly

We are not a VELUX-approved installerVELUX is a registered trade mark of the VELUX Group; we name it only to say whose product we fit. We buy through ordinary trade supply and install to the published instructions, which keeps the product warranty alive.

A pleated blind fitted inside a roof window recess
A blind in the recess does more for July than the glass specification does.
A roof window set between rafters in a pitched coveringThe window sits in the plane of the covering between existing rafters. A flashing kit matched to the covering carries water around the frame, and the underlay is dressed to a collar so anything passing the tiles is returned to the outside.roof windowrafterrafterflashing kitcovering

Start at the data plate — and what to do when the code has gone

Most replacement enquiries begin with a size guessed from the ceiling below. The window already carries the answer.

  1. Rotate the sash. A centre-pivot turns 180 degrees and locks on a barrel bolt.
  2. Find the plate and photograph it square on. A small silver or white label along the top bar, often behind the ventilation flap. Use the flash — etched plates read badly at an angle.
  3. Read the four things on it. A type code; a size code of one letter and two digits; a four-digit glazing code; a manufacture date.

The type code is the model: GGL lacquered pine, centre-pivot; GGU the same in white polyurethane; GPL a pine top-hung; GPU its polyurethane equivalent. The glazing code is the pane make-up, 2070 being the standard double-glazed unit. The size code does the real work — letter for frame width, digits for height.

A roof window seen from outside on a tiled British roof
From outside, the unit sits in the plane of the tiles.
Size code Frame width Frame height Where it turns up
CK02 550mm 780mm Bathrooms and landings; narrow bays
MK04 780mm 980mm The commonest size on Poole bungalow loft conversions
MK06 780mm 1180mm Bedrooms in the roof; the default where headroom allows
MK08 780mm 1400mm Shallow pitches, where height buys the view back
SK06 1140mm 1180mm Wide openings; a rafter gets cut and trimmed

Windows fitted in the 1990s and earlier often carry a three-digit code instead — a GGL 304 or a GGL 606. Some map onto a current size; some were discontinued and have no modern equivalent.

The rule, and the exception

The rule: the code tells us what to look for, the opening tells us what will fit. We measure the trimmed opening between the rafters and up the slope, and order from that. A plate describes a window made to a tolerance and fitted in 1997 with a handsaw.

The exception: a current size in a sound installation can be ordered off the code, with a check measure on the day access goes up. Skip that measure and someone pays when the frame lands 40mm wide of the hole.

Where a size has gone, the old code sometimes proves identical to a current one under a new name; otherwise a slightly smaller size is packed and trimmed in timber, or the opening is altered, which means cutting a rafter. And if the complaint is only a misted pane, the sealed unit is replaceable on most models without touching frame, flashing or tile — we would rather sell a pane than a skylight you did not need.

Like-for-like replacement, or a new opening

Two different jobs, often quoted as one. The difference shows in the covering, the structure, the approvals and the days on site.

What is involved Like-for-like replacement A new opening
Roof covering Tiles lifted roughly a metre around the window and relaid That border plus the opening itself; matching spares matter
Rafters Untouched where the size matches; battens adjusted only Usually a rafter cut, trimmers above and below, neighbours doubled
Approvals Controlled under Part L — must meet the 2.2 W/m²K rooflight U-value Part L plus structural work, to BCP Council Building Control
Time on site One window, one day, opened and closed the same day One to two days, plus a new plastered reveal after

Pitch settles most new openings first. A roof window needs at least 15 degrees, and a top-hung one is limited to 55; below 15 you are choosing a flat rooflight on an upstand instead. Position matters as much — the bottom of the sash wants to sit 900 to 1100mm above the floor so the view works sitting down, and on a shallow pitch a taller window buys that geometry back.

The flashing kit is chosen by what your roof is covered in

The flashing is why a window mid-slope does not leak: pressed aluminium sections — apron at the bottom, soakers up the sides, head flashing at the top — shaped for one particular covering, with an underfelt collar behind returning any water that gets past the tiles back onto the felt. It is not trim. It is the drainage detail.

A centre-pivot roof window propped open in a plain loft room
A loft room with the sash open on its catch.
Covering or situation Kit What it does What the wrong one does
Profiled tiles to 120mm EDW Deep pleated apron dressed into the tile profile A flat apron bridges a pantile roll; rain runs under
Slate and flat coverings to 8mm EDL Thin apron and soakers lying flat on a smooth covering A profiled kit leaves side voids that fill with rain
Recessed installation EDJ tiles, EDN slate Sets the window deeper for a flatter external line Gutters sit lower and hold debris under a pine canopy
Two or more together EKW tiles, EKL slate Combination flashing, shared gutter, set frame spacing Two single kits butted together have no gutter; it leaks

Why the kit is not optional

Lead and mortar dressed round a roof window is not a cheaper flashing kit, it is a worse detail: mortar cracks on a roof that moves, lead over an unventilated frame traps condensation, and neither connects to the collars behind — BFX underfelt, BDX insulation, BBX vapour barrier — which are why a properly fitted window does not stream in February. It also ends the manufacturer’s warranty. A quote should name the kit code and the covering it suits; if it does not, you will find the difference on your ceiling.

How it opens, and what opens it

Centre-pivot or top-hung is the choice people get wrong most often, because showroom logic and lived-in logic disagree. It is settled by where the window sits and whether it is an escape route.

Consideration Centre-pivot (GGL, GGU) Top-hung (GPL, GPU)
How it opens Sash rotates about its middle; bottom swings out, top swings in Hinged at the head; the whole sash swings outward and stays clear
Roof pitch 15 to 90 degrees 15 to 55 degrees
Where the control is Bar across the top of the sash, so it works out of reach Handle at the bottom, so it must be within arm’s reach
Escape route Not an escape window; the pivot leaves no usable clear opening Escape versions open far enough for a compliant clear opening

Where the window is the means of escape from a loft conversion, that is Part B rather than a preference: at least 0.33 square metres of clear openable area, no dimension under 450mm, and the bottom of it between 600mm and 1100mm above the floor. We check that on every loft conversion, including the ones where the original never did.

Then there is what opens it. Manual is cheapest and right whenever you can reach the window; out of reach it means a telescopic rod, charming for a fortnight and an annoyance for a decade. Electric versions run on mains to a control pad with a rain sensor that shuts the window as the first drops land; solar versions do the same from a panel on the sash, and need no cable.

The rule, and the exception

The rule: decide how the window opens before the plasterer arrives. A mains cable costs almost nothing while the ceiling is open, and a redecoration afterwards.

The exception: on a retrofit into a finished room, solar wins nearly every time — a little more than the mains unit, and far less than chased cable, lifted boards and making good.

The rain sensor earns its keep at the harbour mouth. A squall crosses open water at Sandbanks and Lilliput with very little warning. The panel and battery then live outside on the sash in that salt air: the panel itself copes, and the brackets and hinge arms around it are what we upgrade.

Blinds, and the only one that actually stops heat

A room in the roof with a south or west-facing skylight is warm by four o’clock in July, and the usual answer is a blackout blind and mild disappointment. An internal blind sits behind the glass: the sunlight has already become heat before the blind sees it, and radiates it back at you.

The rule, and the exception

The rule: internal blinds control light, external shading controls heat. A blackout blind is right for a bedroom that has to go dark. An external awning — a mesh you can still see through, manual or solar — is the only one that stops the sun before it reaches the glass.

The exception: at the harbour mouth an awning’s fabric and side rails take salt and wind an inland one never sees, so we will say whether it is a sensible buy at your address. Solar control glazing is the alternative there: permanent, nothing to weather, but wasted on a north-facing roof.

Blinds are ordered against the same size code and clip into brackets built into the frame, so the plate you photographed serves the blind too.

Two roof windows in a loft room ceiling slope
Two smaller sashes give cross-light where one large one gives glare.

Which Poole exposure zone your roof sits in

A roof window is unlike everything else we fit, because it moves: hinges, a friction mechanism, a latch, a gasket that compresses thousands of times, and a gap round the sash that salt air gets into. A fixed rooflight is specified generously and then left alone; this has metal that must keep working. And four miles separates the harshest glazing conditions on this coast from ordinary heathland weather, so one build-up quoted across Poole is wrong twice over.

Salt does not attack the glass. It attacks the ironmongery. On the Sandbanks peninsula the first symptom is never a leak — it is a window gone stiff, then one that will not hold its position on a windy day, then hinge arms pitting under the cladding.

The pivot hinge of a centre-pivot roof window with the sash rotated
The centre pivot is what lets the outer face be cleaned from inside.
Exposure zone Poole areas What changes on a roof window Why
Zone 1 — severe marine Sandbanks, the harbour mouth, seaward Lilliput A4 (316) stainless brackets and fixings, polyurethane sash rather than lacquered pine, ironmongery checked at twelve months Salt-laden wind with no fetch break reaches the hinge line; fixings go first, not glass
Zone 2 — sheltered marine Poole Old Town, the Quay, Hamworthy waterside, Parkstone shore Coastal-grade fixings on anything exposed, and a conservation check before a tile is lifted The land behind breaks the south-westerly, so the constraint is as often planning as weather
Zone 3 — wooded and elevated Canford Cliffs, Branksome Park, upper Lilliput Standard flashing rather than recessed, gutters on the service list, self-cleaning outer pane Tree preservation orders make the pine canopy permanent, and a recessed gutter holds more of it
Zone 4 — inland Broadstone, Creekmoor, Canford Heath, Upton Standard brackets, fixings and finish; coastal upgrades priced only if you ask Heathland edge, no salt load — marine specification buys nothing the site will test

Corrosion here is undramatic until it is expensive. Zinc-plated screws bleed rust streaks down a white sash, and once that has run into the finish it does not come off; aluminium cladding chalks, leaving a white residue on a finger drawn across it. So we use stainless where the zone calls for it, and the right kit in the right material so no dissimilar metals sit in salt water at the apron.

Fresh water is the maintenance nobody does. Rinsing the sash and hinge line with a hose twice a year does more for the ironmongery on a Sandbanks roof than any coating. It is what the same household does to a boat’s fittings two hundred metres away.

What actually fails, and roughly when

Most roof windows in Poole needing attention are fifteen to twenty-five years old — the tail of the late-1990s loft-conversion boom. Very little of what fails is the window as a whole, and knowing which part has gone is the difference between a part and a replacement.

A tape measure and notes resting on a roof kerb during a survey
The kerb is measured before anything is ordered.
Part Typical life What you notice What it takes
Sealed glazing unit 15 to 25 years, shorter on an exposed roof Misting between the panes that no cleaning touches Pane replaceable on most models; frame and flashing stay
Sash gasket and seals 10 to 15 years A draught, a whistle in a south-westerly, a damp bottom rail Replacement gasket, about an hour; the cheapest fix here
Hinges, friction and latch First to go on the coast, from around eight years in Zone 1 Stiff to open, then it will not hold position, then it will not lock down Clean and lubricate if caught early; hinge arms replaced if not
The sash itself 20 years and up on lacquered pine Dark staining at the bottom corners, then soft timber Condensation damage, not rain; at that age the whole window is the better spend

A service is an hour and covers the lot: the ventilation flap filter pulled out and washed, a five-minute job nobody knows exists; drainage channels and side gutters cleared; hinges and friction lubricated; gaskets checked along their whole length rather than glanced at. On a Zone 1 roof we suggest that annually; in Broadstone every two or three years is plenty, and we will say so rather than sell you a plan.

The survey, the day, and what we will not claim

We do not price a roof window from a photograph of a ceiling. The survey comes first, produces a fixed written price, and settles what otherwise becomes a variation halfway through the job.

  1. The exposure zone, named in writing. Which of the four zones the address sits in, and the fixing grade, sash finish and service interval that follow.
  2. What is up there now. Data plate read and photographed, and whether the existing window got a proper flashing kit or a mortar fillet.
  3. The opening and the covering. Rafter centres, the trimmed opening, whether your size is still made, and how deep the tile profile runs — which names the kit code on the quote.
  4. Pitch and position. Measured pitch, sill height off the floor, and the Part B escape check on every loft conversion.
  5. Access and approvals. Scaffold or tower; a Part L replacement or structural work for BCP Council Building Control; and conservation status — around the Old Town and the Quay, a ten-minute check and an expensive assumption.
  6. The price, in writing. One itemised figure, with any roof repair shown separately.

How long is my roof open

Covering off in the morning, new window and flashing in, weathertight before we leave — and on a new opening, weathertight at the end of each day. Nothing is left open overnight. We will move a fitting date for weather: handling a sash on an exposed roof in a stiff south-westerly is where people get hurt.

This is a new firm.

The two things we put in writing

A ten-year workmanship guarantee on our installation — the fit, the flashing, the weathering detail. It is not insurance backed, and we say that plainly because the difference matters. The window and its ironmongery carry the manufacturer’s own warranty, handed over with the paperwork.

A fixed written price after survey. Not a range, not a guide. If something unforeseeable appears once the covering is off — rotten sarking, an untrimmed rafter — we stop, photograph it, show you, and price the repair separately.

We install and replace roof windows, flat rooflights, lanterns and walk-on glazing across Poole and about thirty miles around it. We are not a general roofing firm: if your covering needs replacing first, we will say so. If you have a misted pane, a stiff sash, or a skylight that has leaked since somebody dressed mortar round it, ring 01202 923272 with the size code and your road name. We can give you the zone and say whether your size still exists before anyone comes out.

A rooflight unit being lowered onto a prepared kerb
A prepared kerb, squared and weatherproofed, before the unit goes on.

In this section

Answer

Can a VELUX be converted from manual to electric?

Usually yes, if the unit is from roughly the last twenty years. A retro-fit kit replaces the top control bar…

Answer

Can a VELUX be fitted to a flat roof?

Not as it comes. A standard pitched-roof unit needs a slope of roughly fifteen degrees or more to shed water…

Answer

Can a VELUX be fitted to a roof with solar panels?

Yes, but it stops being a roofing question and becomes a clearance and sequencing one. A flashing needs a clear…

Answer

Can a VELUX be replaced with the same size unit?

Usually yes. The standard size grid has been stable for decades, so a like-for-like frame is normally available, but “same…

Answer

Can a VELUX window be repaired?

Yes, more often than not. Glass, gaskets, filters, handles, friction components and flashings are all replaceable on their own. The…

Answer

Can I fit a blind to an old VELUX window?

Usually yes, provided you can read the size and type codes off the data plate. Manufacturer blinds are made to…

Knowledge

Canford Cliffs pine debris and the VELUX drainage channel it blocks

Under a mature pine canopy a roof window is not dealing with autumn. It is dealing with a continuous, year-round…

Answer

Do VELUX frames need repainting sooner near the harbour?

The outside does not need painting at all. The external face of a modern roof window is aluminium cladding, and…

Answer

Do VELUX windows come with flashing included?

No. The window comes in one box and the flashing comes in another, with its own code, chosen by what…

Answer

Do VELUX windows in Canford Heath need the same spec as Sandbanks?

No. Four miles apart, and the exposure is not comparable. Sandbanks is a sand spit with water on both sides…

Answer

Do VELUX windows need a safety bar or restrictor?

Not as a blanket rule. Two separate requirements apply to a roof window and they pull in opposite directions: guarding,…

Answer

Does the VELUX manufacturer guarantee still apply once fitted?

Yes, on the product. A manufacturer guarantee covers the unit against defects on its own published terms, and fitting it…

Get a fixed quote

Tell us which way your roof faces.

We will come back with a specification, not a catalogue page. If your extension faces south we will tell you the G-value we would fit and why.

  • No pressure, no doorstep sales call
  • We handle the Building Control notification
  • 10-year workmanship guarantee on every installation
  • Installations and replacements across Poole and south Dorset

Prefer to talk it through? 01202 923272