Insulation at the window perimeter and the cold corner it prevents

How the insulation collar and vapour control layer around a roof window frame are built, and what happens at the corners when they are not.

Exposure zones across the Poole service areaExposure changes within about four miles. The harbour mouth and the spit take salt-laden wind with no fetch break; the Quay and Old Town are sheltered by the land behind them; the wooded cliffs add debris and canopy; inland is ordinary exposure where a marine specification is an overcharge.spitharbourwooded cliffinlandmost aggressiveordinaryabout four miles changes the specification

The dark line in the corner of a new reveal

About eighteen months after a roof window goes in, a certain kind of installation announces itself. A faint grey line appears along the corner where the reveal meets the ceiling, usually at the two top corners first. It darkens over a winter. Wiped off, it comes back. Painted over, it comes back through. It is almost always reported to us as a leak.

It is not a leak. It is mould growing on a surface that is colder than the air around it, and the surface is colder because the insulation stops somewhere it should not. Everything on this page exists to prevent that one line, and the prevention costs an hour of care at the right moment.

A thermal bridge, described the way it looks on site

Insulation in a roof works as a continuous layer. Wherever that layer is interrupted by something more conductive, heat takes the short cut, and the inside surface at that point runs colder than the surfaces either side of it. That is a thermal bridge, and a hole cut in a roof for a window creates a perimeter of them: 4 to 5 metres of edge where the main insulation has been cut through.

The consequence is not primarily a heating bill. On one window, the heat loss is small. The consequence is surface temperature. Indoor air holds a certain amount of moisture, and when it touches a surface below its dew point that moisture condenses out. A reveal corner at 12 degrees in a room at 20 with normal humidity is sitting right on the edge, and mould germinates at surface humidity well below actual condensation. You do not need visible water for the line to appear.

Dorset’s climate makes this worse than a colder, drier one would. The coast here is mild and damp: winters rarely hard, humidity high, and long runs of grey wet weather where nothing dries out. That combination keeps indoor humidity elevated for months rather than days, so a marginal surface temperature has a long time to do damage. A reveal detail that would get away with it in a dry continental winter will not get away with it in a wet February between Poole and Christchurch.

The five places heat leaves around a frame

Where What causes it What the fix is
The gap between frame and trimmer The fitting gap left all round so the frame can be squared and packed Filled completely with insulation, not partly, and not with expanding foam as a structural packer
The trimmers themselves Solid timber head and sill members conduct far better than insulation Insulation carried over or under them where the build-up allows, not stopped at their face
The reveal liner Battens and timber liners fixed to carry the plasterboard, with air behind them Insulate behind the liner, or use a build-up that puts the insulation on the cold side of it
The corners of the opening Awkward geometry where head meets side, so the collar gets cut short or bridged Cut and fitted as a deliberate detail. This is where nearly every failure is
Air leaking round the perimeter Gaps in the vapour control layer letting warm moist room air into the construction A continuous, taped, sealed line. Insulation alone does nothing about this

What the collar is made of, and how much of it fits

The insulation collar is the band of insulation that wraps the frame and ties the main roof insulation to it. Three materials are commonly used and they are not interchangeable in every situation.

Mineral wool is soft, cheap, easy to shape and tolerant of irregular gaps, which is why it suits old roofs where nothing is straight. It needs to be fitted to a consistent density: stuffed hard it loses performance, left loose it slumps within a few years and opens a gap at the top of the frame precisely where you least want one. Rigid boards such as PIR give more performance per millimetre, which matters badly in a shallow rafter, but they must be cut accurately and the inevitable slivers of gap taped or filled, because a 5mm air path round a rigid board undoes a good deal of its advantage. Proprietary pre-formed collars made for a specific frame size are the neatest answer where they exist and the frame is a standard one.

Thickness is set by what is left between the frame and the trimmer, and that is the uncomfortable part: the fitting gap is often only 20 to 30mm wide, which is nothing like the thickness of the roof insulation it is joining onto. Which is why the collar alone is never the whole answer, and why the reveal build-up matters as much as the gap.

Insulation at the window perimeter and the cold corner it prevents
Set in the plane of the covering, with the flashing matched to the slate.

Rafter depth decides how much you actually get

Rafter depth Where it is found Room for insulation What we do about it
100mm Pre-war and interwar cut roofs across older Poole and Parkstone Very little, once a ventilation gap is kept above High-performance board plus an insulated lining under the rafters. The reveal gets thicker and the head plumb line matters more
125mm to 150mm Later post-war construction and many trussed roofs Workable, with care at the perimeter Between-rafter board plus a modest under-rafter layer carried onto the reveal
175mm to 200mm Modern loft conversions and new build Generous The collar can be genuinely continuous with the main layer. The best case
Rafters plus an over-rafter layer Warm roof conversions and full re-roofs Best of all, with the bridge largely designed out Recessed installation becomes possible, which also improves how the unit looks from outside

The general principle holds across all four rows: where there is not enough depth between the rafters, the shortfall is made up on the room side, and the reveal is where that extra thickness lands. It is the reason a well-insulated reveal in an old roof is deeper than people expect.

Airtightness is a separate line, doing a separate job

Two layers, two purposes, both continuous

Insulation slows heat moving through a material. It does nothing whatever about warm, moisture-laden room air travelling through a gap and depositing that moisture somewhere cold inside the construction. That is what the vapour control layer is for, and it only works if it is continuous and sealed: lapped onto the window frame, taped at every joint, and not punctured by downlights, cable runs or fixings that nobody sealed afterwards.

A perfect insulation collar behind a leaky vapour control layer will still deliver damp at the perimeter, because the air carries far more moisture into a construction than diffusion ever does. Both layers, every time, and the tape is not the place to economise.

Corners, which is where it always goes wrong

If you were to photograph the failures, they would nearly all be at the two upper corners of the opening. There are reasons. The geometry is three-dimensional and awkward, so soft insulation gets pushed in rather than cut to fit. The head trimmer and the side liner meet there, giving two pieces of conductive timber crossing. It is the highest point of the opening, so the warmest, moistest air in the room collects there. And it is the last place anybody can reach comfortably when the board is going on.

The answer is to treat each corner as its own detail rather than as the end of two runs: cut the collar pieces to meet properly, tape the vapour layer across the corner in one piece rather than two butted ones, and check both corners by hand before any board goes up. Thirty seconds each, and it is the difference between a reveal that stays clean and one that does not.

Insulation at the window perimeter and the cold corner it prevents
A profiled tile needs a deeper flashing than a slate does.

Building the perimeter, in order

  1. The frame is fixed, squared, and checked for wind before anything is insulated, because nothing behind the collar can be adjusted afterwards.
  2. Any ventilation path that must remain above the insulation is established and protected, so the collar cannot later block it.
  3. The collar is cut and fitted all round, full depth, full width, with corners cut rather than stuffed.
  4. The main roof insulation is brought up tight to the collar so there is one continuous layer, not two layers with a gap between them.
  5. The vapour control layer is dressed onto the frame, lapped onto the main layer, and taped at every joint and corner.
  6. Liners and board go on, with the reveal geometry set for daylight rather than convenience. That detail is on plasterboard reveals.

What a skipped collar looks like two years on

In the first winter, usually nothing. In the second, the grey line at the corners, worst on a north-facing slope and worst in a bathroom or a bedroom. Alongside it, condensation running on the frame on cold mornings, a reveal that feels cold to the back of the hand compared with the ceiling a foot away, and occasionally a slight cupping of the plasterboard as it takes up moisture.

The diagnosis that separates it from an actual leak is simple and worth knowing: a leak appears during or shortly after rain, and it usually runs. Condensation at a thermal bridge appears on cold mornings regardless of rain, is worst at corners rather than at one point, and improves within hours of the room warming through. The wider question of loft moisture is dealt with on do roof windows cause condensation.

What we check, and what we photograph

Rafter depth and the build-up we can achieve in it. The ventilation path and whether the collar threatens it. The four corners, by hand, before boarding. And the vapour control layer at the frame, which we photograph, because once the plasterboard is on it is the one part of the job nobody can ever inspect again. Those photographs go to the homeowner with the paperwork.

The perimeter is the same problem whether the unit is called a roof window, a skylight in a homeowner’s search or a rooflight on a builder’s schedule: a hole in an insulated layer has an edge, and the edge is the job. Our installations carry a ten-year workmanship guarantee, stated plainly as not insurance backed, with a fixed written price after survey. Ring 01202 923272.

Get a fixed quote

Get a fixed quote

Tell us which way your roof faces.

We will come back with a specification, not a catalogue page. If your extension faces south we will tell you the G-value we would fit and why.