Rooflight area against floor area, and the daylight factor behind it

The ratio of glazed area to floor area is a daylight calculation in disguise, and understanding the sum behind it explains why roof glazing is worth several times its area in wall glazing and where the rules of thumb stop working.

U-value and g-value pull in opposite directionsU-value measures heat leaving through the unit; g-value measures solar energy coming in. A coating that cuts summer gain also cuts the winter daylight and warmth a room receives, which is why the right answer depends on orientation and on what shades the roof.solar energy ing-valueheat outU-valueglazed unitlowering one usually raises the other

How big should it be, and the sum hiding behind the question

It is the first question on almost every job and the one most often answered with a shrug and a standard size. The honest answer is that the aperture size is the output of a daylight calculation, and although nobody is going to run a full one for a kitchen extension, knowing what the calculation contains tells you when the rule of thumb will serve and when it will let you down.

It is also the decision that cannot be revisited. Glass specification can be argued about until the unit is ordered; the hole in the roof is structural, and enlarging it later means trimmers, a new kerb and a reroofed area around it.

Daylight factor: a ratio that ignores the weather

What the number means

The daylight factor is the light inside a room expressed as a percentage of the light outside at the same moment, under an overcast sky. Because it is a ratio, it does not change when a cloud passes — both halves move together. That is what makes it useful: it describes the room rather than the day.

The long-standing orientation figures used in British practice are that an average around 2% gives a room that reads as daylit but will want electric light for detailed tasks, and an average around 5% gives a room that rarely needs the lights on in daytime. Those are guidance figures for judging a design, not a compliance standard, and no authority will ask you for them on a domestic extension.

Why roof glazing beats wall glazing, by a long way

The reason is what each one can see. A horizontal rooflight faces the entire sky dome, unobstructed, in every direction. A vertical window sees at most half of the dome, and much of what fills its view is not sky at all but ground, fences, hedges and the house opposite — all of which are far darker than the sky and contribute very little.

The rule of thumb that follows, used in daylight practice for decades, is that a given area of roof glazing delivers roughly two to three times the daylight of the same area of wall glazing. That is an orientation figure rather than a calculation, and the multiplier falls as the rooflight is pitched more steeply or as overhead obstruction increases. It is nonetheless the single most useful fact in this subject: a modest skylight does the work of a large window, which is why the rule-of-thumb ratios for rooflights look so small.

The three parts of the light in a room

Component Where the light comes from What changes it
Sky component Directly from the visible patch of sky through the aperture Aperture size, pitch, obstruction overhead, reveal depth, and the glass light transmittance. Dominant for a rooflight
Externally reflected component Off surfaces outside — the ground, a wall, water, a light-coloured roof What is outside and how bright it is. Usually small for a rooflight, and unusually large where water is in view
Internally reflected component Bouncing around inside off walls, ceiling and floor before reaching the point measured Room surface colours and gloss. A dark room can lose a great deal of the light it has already admitted

The third row explains the cheapest daylight improvement available, and it is not glazing. Painting a deep room in pale matt finishes raises the internally reflected component everywhere at once, at a cost that does not compare with cutting a hole in a roof.

Rooflight area against floor area, and the daylight factor behind it
A neutral coating you can just see at an angle, and barely at all from below.

The rules of thumb, and where they break

Condition Push the glazed area up when Pull it back when
Obstruction above Trees, a neighbouring wall or an adjoining roof cut into the sky view Open sky in every direction, as on a flat coastal roof
Reveal depth A deep warm deck or a thick roof means a long shaft between glass and ceiling A thin roof build-up, or a splayed reveal recovering the loss
Room depth and shape A deep plan where the far end is a long way from any window A shallow room that already has good wall glazing
Surfaces Dark floors, dark units, a strongly coloured ceiling Pale matt walls and ceiling throughout
Glass A diffusing, tinted or heavily coated unit with reduced light transmittance Clear low-emissivity glazing at the top of the transmittance range
Use A kitchen, a workshop, a desk, anywhere with close work A circulation space, a landing, a shower room

As an orientation only, a glazed area somewhere around a tenth of the floor area beneath it gives a well-lit room on an unobstructed roof, and rooms under heavy overhead obstruction need appreciably more than that. Treat it as a starting point to be adjusted by the six rows above, never as a specification.

Distribution beats total area

Two smaller rooflights set apart will almost always produce a better room than one of the same total area in the middle. Light reaches more of the plan, the shadows are softer because they are lit from two directions, and the contrast between the bright aperture and the ceiling around it — the thing that reads as glare — is lower for each one.

There is also a specific trick a rooflight can do that no window can. In a deep plan there is a line beyond which no sky is visible from working height, and past that line a window contributes almost nothing however large it is. A skylight lights the far end of a plan directly. That is why a long Victorian terrace in Parkstone or Westbourne with a dark middle is a better candidate for two modest rooflights than for a bigger rear window.

The reveal is a light fitting, and usually a bad one

A rooflight in a warm deck roof is at the top of a lined shaft that can easily be two or three hundred millimetres deep, and considerably more where insulation has been built up. That shaft restricts the angle from which sky can be seen, so the effective aperture at ceiling level is smaller than the glass.

Splaying it recovers much of the loss. Cutting the lining back so the opening widens as it comes into the room lets more sky reach more of the floor, and gives the reveal faces themselves something to do: finished matt and pale, they become an intermediate brightness that both spreads the light and softens the contrast at the edge of the aperture. The same move helps with glare, as set out on south west facing roofs and the glare they catch.

More glass is not free

Three costs that rise with area, and one that does not

Heat loss rises with area. A rooflight is almost always the weakest element in the roof, and doubling its area doubles its share of the loss. The comparison with walls is on do rooflights lose more heat than walls.

Solar gain rises with area. A coating reduces the energy per square metre; it does nothing about how many square metres there are. Area is the first term in that sum and the coating is the second.

Compliance gets harder. Approved Document L caps the glazed area in a new extension as a proportion of its floor area, with an allowance for openings being closed up. Exceed the cap and you move to a calculated route rather than a simple elemental one — the mechanics are on Part L, SAP and how a rooflight is counted, and the edition current on the day governs.

Daylight does not rise proportionally. Doubling the aperture does not double the perceived brightness, because the eye responds to light on something close to a logarithmic scale. The second half of the glass always feels like less than the first.

Rooflight area against floor area, and the daylight factor behind it
Clear glass on a south slope in July. The light is the problem, not the heat alone.

Poole rooms where the sum comes out differently

Under the Branksome Park and Canford Cliffs pines, overhead obstruction removes much of the sky component permanently, so these rooms need more glazed area than an unobstructed roof to reach the same result — and the glass should be the clearest available. The full picture is on pine canopy shading in Branksome Park.

Harbour-front rooms at Sandbanks, Lilliput and the Quay have an unusually large externally reflected component, because open water is a bright surface and there is no obstruction at all. These rooms measure and feel brighter than the aperture alone would predict, and are the one case where erring small is sensible.

Deep Victorian and Edwardian plans in Parkstone, Penn Hill and Westbourne are the classic case for two modest rooflights rather than one large one, placed to reach the part of the plan no window can.

North-facing slopes anywhere in the service area receive steady, even, indirect light with no direct sun. Glare is not an issue, solar control is wasted, and area is the only lever worth pulling.

Setting the area so it survives the build

  1. Measure the floor area of the room, not the extension, and note how much usable wall glazing it already has.
  2. Look up. Record what obstructs the sky from the proposed position, and whether it is permanent.
  3. Decide distribution before size. Two apertures or one, and where, then total the area.
  4. Check the reveal depth the roof build-up will produce, and decide then whether to splay it.
  5. Check the structure. A larger aperture means trimming, and trimmers have depth implications for the ceiling below.
  6. Check the compliance route if it is an extension, before the size is fixed rather than after.
  7. Get the declared light transmittance for the unit you are actually buying, because a diffusing or heavily coated unit changes the area you needed.

What we do on survey

We measure the room, record the obstruction, look at what the space is for, and propose a size and a distribution with the reasoning attached. Where a smaller aperture would do, we will say so, because a rooflight that is bigger than it needs to be costs more to buy, loses more heat, gains more in summer and can push an extension into a calculated compliance route for no gain in how the room feels.

We will not quote a daylight factor for a room we have not modelled, and we do not publish prices. Our installation work carries a ten-year workmanship guarantee — a workmanship guarantee, plainly, and not insurance backed — with a fixed written price after survey. Ring 01202 923272 with the room dimensions and a note of what is above the roof, and the size will follow from those.

Get a fixed quote

Get a fixed quote

Tell us which way your roof faces.

We will come back with a specification, not a catalogue page. If your extension faces south we will tell you the G-value we would fit and why.

  • No pressure, no doorstep sales call
  • We handle the Building Control notification
  • 10-year workmanship guarantee on every installation
  • Installations and replacements across Poole and south Dorset

Prefer to talk it through? 01202 923272