Matching a new unit to an existing kerb without rebuilding it

Where the upstand is sound but not perfect, adaptation is a set of techniques with known limits rather than a compromise.

How a sealed unit fails and mistsA sealed unit holds dry air or argon between two panes, kept dry by desiccant in the spacer bar. Daily heating and cooling pumps the cavity; once the edge seal loses its grip, moist air is drawn in, the desiccant saturates, and the misting that appears between the panes cannot be cleaned because it is on the inside.cavity: dry air or argonspacer with desiccantedge sealmisting sits between the panes, so it cannot be cleaned offmoist air

Assume the upstand is sound. Assume it has been sounded all round, the deck under it is dry and nobody has found rot at the corners. What remains is the ordinary situation on almost every replacement we look at: a kerb that is structurally fine and dimensionally nothing like what a current rooflight expects.

That gap is closed by adaptation, and adaptation is a set of techniques with known limits rather than a fudge. This guide sets out what those techniques are, how far each will stretch, and the point at which the honest answer becomes carpentry. Whether your kerb is sound in the first place is a different question with its own page; this one begins after that verdict.

How much tolerance a fixed unit really has

Less than people assume, and in a different direction. A rigid glazed unit is not troubled by being a few millimetres smaller than the opening, because the perimeter detail covers that. What it will not tolerate is being asked to sit on a surface that is not in one plane. Three points define a plane; a fourth corner sitting proud or low puts the whole assembly into twist, and everything after that is the perimeter seal carrying a load nobody designed it to carry.

So the measurement that matters is not width and length. It is how far the top surface of the upstand departs from flat, taken across both diagonals as well as along the sides. That is the number adaptation has to eliminate, and it is the number nobody takes over the phone.

Five ways of landing a unit on an imperfect kerb

Method What it solves Practical limit Disturbance to the roof
Shimming and packing Small departures from level at one or two points A few millimetres, and only where the packer is fully supported None
A continuous liner A top surface that is sound but chewed, notched or out of plane all round Anything the liner can be bedded onto without bridging a void Minimal, if the covering already terminates below the top
Adaptor frame An opening that is the wrong size for any current product, or the wrong shape Reducing an opening is easy; enlarging it is structural Low to moderate
Upstand collar An upstand that is too short for the exposure The covering has to be taken up the new face and terminated properly Moderate. This is roofing work as well as carpentry
Re-topping Twist, and fixing holes that have been used twice already Requires the body of the upstand to be genuinely sound Moderate, but it keeps the deck and most of the covering intact

The first three are glazing operations. The last two cross into roofing, which is why they belong on a quotation as separate lines rather than being absorbed into a glazing price and discovered later.

Packing, and the way it is usually got wrong

A packer is a load path, not a spacer. It has to be rigid, non-compressible, stable when wet and continuous enough that the unit bears on it rather than spanning over it. Slivers of timber, folded damp-proof membrane and, worst of all, extra sealant used as a packer are all ways of putting a soft spot under a perimeter that then flexes with every thermal cycle. The sealant case is the common one: a bed of mastic dialled up thicker on the low side to fake a level. It holds for a winter and then the unit settles into it.

Where packing is correct it is rigid packers at defined points, sized so the bedding line stays an even thickness all the way round, and no single packer carrying a corner on its own.

Why the bedding thickness must stay even

A perimeter bed is designed to a thickness. Too thin and it cannot accommodate movement; too thick and it slumps, skins over and cures unevenly. Where a kerb is out of level and the answer has been to vary the bed, you have built a perimeter whose stiffness changes as you walk round it, and the unit will move differently at each side. The corners take that difference. This is a slow failure rather than a leak on day one, which is exactly why it keeps being repeated.

Matching a new unit to an existing kerb without rebuilding it
The perimeter seal is the part that ages, and it fails from the edge inward.

Thermal movement, and not clamping it solid

The rule, and the exception

The rule. A rooflight frame and a timber upstand move at different rates and in different directions, and the fixing arrangement has to allow that. Fixings go where the manufacturer specifies, at the specified spacing, through the specified holes, and they are tightened to hold rather than to crush. Over-tightening a frame down onto an uneven kerb is the fastest way to introduce exactly the twist the packing was supposed to remove.

The exception. Exposure changes the fixing schedule. On the sand spit at Sandbanks, at the harbour mouth, or on any elevated roof at Canford Cliffs, wind uplift is the governing load and the fixing pattern is tightened accordingly, in stainless of the right grade. That is a different decision from clamping the frame flat, and it does not license it. Four miles inland at Broadstone or Ferndown the standard schedule is the right answer and paying for a marine specification there is paying for a threat that is not present.

Fixings into a thirty-year-old upstand

An old upstand has been fixed into before, often twice, and generally at the corners where the timber is end grain and weakest. Reusing those holes gives a fixing that feels tight and holds nothing. The answer is to set a new pattern that deliberately avoids the old one, to fix into the body of the timber rather than its end, and where the top has been peppered, to re-top rather than to keep hunting for sound material.

Material matters as much as position. A stainless fixing through an aluminium frame is a galvanic pair, and near salt water that pairing needs isolating washers or the right grade and finish, not optimism. Inland the ordinary specification is fine, and we will say which applies at your address rather than defaulting to the expensive answer everywhere.

Sealing to a face that is not flat

Sealant has a working joint width and a maximum depth, and neither is negotiable by putting more of it on. Where the mating face is uneven, the correct sequence is to make the face right and then seal, in that order. A bead squeezed into a varying gap cures at different rates through its section, skins before the depth has gone off, and pulls away from the shallow side first.

The related error is sealing the wrong side of the detail. Most rooflight systems are designed to drain, not to be watertight at the outer face. Sealing across the drainage path traps the small amount of water the system was built to release, and it then finds the inside. If a previous installer has run mastic all round the outside of the frame, that is usually a symptom of an earlier problem rather than a cure for it.

Matching a new unit to an existing kerb without rebuilding it
Misting sits between the panes, which is why cleaning never touches it.

What cannot be adapted

  1. A soft upstand. Nothing fixes into rot, and packing over it simply moves the failure a year down the road.
  2. An upstand with no insulation in a room that is heated, where the cold bridge will condense whatever is put on top of it.
  3. A kerb whose top is below the finished covering at any point, which is a drainage fault before it is a glazing one.
  4. An opening that needs enlarging, which means trimming joists and becomes a structural job with its own regulatory position.
  5. A twist bigger than packing can take, which is the point at which re-topping is not the expensive option but the only honest one.
  6. A deck that is wet under the perimeter, because the roof is telling you the problem is not the rooflight at all.

Falls, and the Poole roof that is not flat

Almost no flat roof in this area is flat, and that is deliberate. A designed fall moves water off the covering and away from the perimeter of the opening, and where the fall has been lost through deck deflection or a settled firring, water stands against the very seal that has to stay dry. It is why so many misted units on Poole extensions have failed at the low corner first. Adaptation can correct a kerb top to level, but it cannot create a fall in a roof that has lost one. Around the harbour and out on the spit that matters more than it does inland, because driven rain off the water arrives horizontally and the amount of water crossing the perimeter in a south-westerly is not comparable to a sheltered garden at Wimborne. Where we find a lost fall, we say so as a roofing item and price it separately, because a new skylight bedded into standing water is a repeat of the failure you have just paid to remove.

What the survey settles

Eight things, all measured rather than assumed: the four dimensions at the top of the upstand, both diagonals, the departure from plane at each corner, the upstand height above the finished covering on each side separately, the condition and species of the timber, the covering type and how it terminates, the fixing history visible in the top, and the exposure zone the address sits in. From those we can say which of the five adaptation methods applies, what it disturbs, and whether anything has to be rebuilt.

That becomes one fixed written price with glazing, carpentry and roofing shown as separate lines. We do not quote adaptation over the phone and we do not publish a figure, because the numbers above are the price and none of them are visible from the ground. Our installation work carries a ten-year workmanship guarantee, given directly by us, which is not insurance backed. To get it looked at, ring 01202 923272 or send photographs of each corner of the upstand to 447880284133.

Get a fixed quote

Get a fixed quote

Tell us which way your roof faces.

We will come back with a specification, not a catalogue page. If your extension faces south we will tell you the G-value we would fit and why.

  • No pressure, no doorstep sales call
  • We handle the Building Control notification
  • 10-year workmanship guarantee on every installation
  • Installations and replacements across Poole and south Dorset

Prefer to talk it through? 01202 923272