What a rooflight U-value covers and what it quietly leaves out

What a declared rooflight U-value includes, the three conditions attached to it that rarely appear on a quotation, and the parts of the heat loss the number never covers at all.

U-value and g-value pull in opposite directionsU-value measures heat leaving through the unit; g-value measures solar energy coming in. A coating that cuts summer gain also cuts the winter daylight and warmth a room receives, which is why the right answer depends on orientation and on what shades the roof.solar energy ing-valueheat outU-valueglazed unitlowering one usually raises the other

Two quotes, two numbers, and not the same test

Two firms price the same opening. One comes back with a better U-value than the other and the decision looks made. It is not, because a U-value is a declared figure calculated under a defined set of conditions, and several of those conditions vary between manufacturers without ever reaching the quotation.

None of that is dishonest. Every figure involved is real and calculated to a published standard. The difficulty is that the standard permits more than one true number for the same piece of glass, and only one of them describes the thing that will end up over your kitchen.

What follows is what the number covers, the three conditions attached to it, and the heat loss it does not account for at all. The whole-picture version of the specification sits on the energy efficient rooflights page; this one stays on the number itself.

What a U-value is actually counting

A U-value is a rate of heat loss: watts passing through each square metre for every degree of temperature difference between the inside and the outside. Lower is better. A unit at 1.1 loses roughly half as fast as one at 2.2 under the same conditions, and that is the whole of the arithmetic.

Three things are worth holding onto. It is a steady-state figure, so it assumes settled conditions rather than a February night with a south-westerly across it. It is a rate rather than a quantity, so it tells you nothing on its own about the bill without the area and the temperature difference beside it. And it counts conduction outwards only, which means the sun coming in is a separate number entirely, dealt with by the g-value on g-value and solar gain: why a summer room refuses to cool down.

The one-line version

A U-value describes how fast a square metre of the unit leaks heat under laboratory conditions. It does not describe how warm the room will be, how much the skylight will cost to run, or how the assembly around it behaves once a builder has fitted it.

Whole unit or centre pane: the first question

This is the single largest source of two quotes that cannot be compared. The same sealed unit yields two legitimate figures depending on how much of it was included.

Figure What it includes Why it matters on a rooflight
Centre pane The glass only, measured away from the edges. No spacer, no edge seal, no frame The flattering number. It leaves out precisely the components where a rooflight loses most of its heat
Whole unit Glass, spacer, edge seal and frame, area-weighted across the finished unit The one Building Control is interested in, and the only one worth putting next to another quote
Glass unit only The sealed unit including its edge, but not the frame it sits in Useful when comparing glass specifications, misleading when compared against a whole-unit figure

A small rooflight suffers worst from the difference. Frame and edge are a fixed band around the perimeter, so the smaller the pane, the larger the share of the unit that band represents, and the further the whole-unit figure sits from the centre-pane one. A modest skylight over a landing can be a long way adrift of its own glass specification for that reason alone.

Which way up it was declared

The second question, and the one almost nobody asks. A sealed unit tested standing upright performs better than the same unit lying near-horizontal, because the gas in the cavity convects far more freely when the cavity is on its back. Warm gas rises off the inner pane, crosses to the cold outer pane, drops, and returns — a loop that a narrow upright cavity largely suppresses and a horizontal one does not.

For the replacement standard in England the U-value of a rooflight is assessed in the vertical plane. That is a deliberate convention that puts rooflights on the same footing as windows for compliance purposes. It is also the reason a unit can be entirely compliant on paper and still lose heat faster than its certificate suggests once it is lying at three degrees over a Broadstone extension.

Ask which plane the figure was declared in. Vertical is the normal answer and the correct one for compliance. A figure declared at the installed pitch is a different and usually worse number, and comparing one against the other is comparing two different tests. Whichever is quoted, the manufacturer’s declared figure for the specific unit is what governs — not a generic value from a brochure, and not an estimate from us.

What a rooflight U-value covers and what it quietly leaves out
The kerb is measured before anything is ordered.

The area the number is divided by

A U-value is per square metre, which raises an obvious question on a unit that is not flat: which square metres? A domed rooflight, a pitched roof window or a lantern all have more glass in them than the hole in the roof they cover.

The convention for rooflights is the developed area of the glazing — the actual surface, not its shadow on the ceiling. That is the honest way to do it, because it is the real surface losing the heat. It also means a domed skylight and a flat one covering the same opening are not directly comparable by U-value alone: the dome has more surface area through which to lose heat at the same rate per square metre.

When a quotation gives a U-value for a shaped unit, it is worth confirming the area basis. It changes the figure, it is calculated rather than measured, and it is the sort of detail that silently makes one quote look better than another.

What the figure leaves out entirely

All three questions above are about the unit. The larger omission is everything the unit is fitted into, none of which the declared figure describes.

Left out of the figure What it does to the real heat loss Where it is settled
The kerb A continuous ring of timber standing proud of the insulation line. Left uninsulated it can leak more than the glass it carries At construction, not at ordering. It cannot be corrected afterwards without opening the roof up
The junction to the roof A linear thermal bridge all the way round. It is accounted separately in a calculation, as a psi value, and it is usually assumed rather than calculated In the detailing, by whether the insulation line runs continuously up to meet the frame
The internal reveal Plasterboard returned onto cold structure gives a cold band inside the room and a place for condensation to start By insulated reveal board and a continuous vapour control layer behind it
Installation quality Gaps behind the frame, compressed or missing insulation and an unsealed perimeter all bypass the glass entirely On site, by whoever fits it. No certificate covers this
Air leakage An opening sash with a tired gasket loses heat by moving air, which a U-value does not measure at all By the unit’s air permeability class and by maintenance
Exposure The declared figure assumes a standard external surface resistance. Wind strips heat off the outer pane faster than that assumption allows Nowhere. It is why an exposed roof never quite delivers the lab figure

Read together, that table explains a familiar result: an excellent unit in a poor opening underperforms a merely good unit in a well-detailed one. The certificate describes a component; the room experiences an assembly.

The 2.2 limiting standard, and what it is not

Replacing a rooflight in an existing home in England is controlled work under Part L, and the limiting standard for a replacement is 2.2 W/m²K, assessed in the vertical plane as above. BCP Council Building Control, or an approved inspector, signs it off.

That figure gets quoted at homeowners as though it were a target. It is a ceiling: the worst performance you are permitted to install. A good argon-filled double with a low-emissivity coating typically lands somewhere around 1.0 to 1.4 W/m²K as a whole unit, well inside the limit, and the declared figure for the actual unit is the one that counts rather than any of those typical ranges.

Where the standard bites, and where it does not

It applies to the unit. Meeting 2.2 says nothing about the kerb, the junction or the reveal, and a compliant rooflight can still sit in a thoroughly cold-bridged opening.

It is a minimum, not a specification. Anyone selling on the strength of meeting it is telling you their unit is legal, which is the least that can be said about it.

Different work, different route. A rooflight in a new extension is assessed as part of that extension’s overall calculation rather than against the replacement figure alone. Which route applies is confirmed with Building Control, and we never state an outcome before it is.

What a rooflight U-value covers and what it quietly leaves out
A prepared kerb, squared and weatherproofed, before the unit goes on.

Reading a declared figure off a quotation

  1. Find out whether it is whole unit or centre pane. If the quote does not say, it is worth assuming centre pane until told otherwise, because that is the number that flatters.
  2. Ask which plane it was declared in. Vertical for compliance. Anything else is a different test and cannot be set against a vertical figure.
  3. Check the area basis on a shaped unit. Developed glazing area is the convention for a dome or a pitched lantern.
  4. Ask for the manufacturer’s declaration, not a sales figure. The unit has a declared performance in its own documentation. That is what governs, and it should be available before you order.
  5. Ask the spacer type in the same breath. A warm edge spacer moves the whole-unit figure and lifts the glass edge temperature, where condensation begins on a skylight.
  6. Ask what happens at the kerb. The answer tells you more about the finished heat loss than any decimal place on the glass.
  7. Get all of it in writing before ordering. A sealed unit specification cannot be changed after manufacture, and neither can a spacer.

The same number behaves differently across Poole

A declared figure assumes a standard exterior. The service area does not supply one. At Sandbanks and the harbour mouth, wind arrives off open water with no fetch break and takes heat off the outer pane faster than the calculation’s assumed surface resistance allows, so an exposed roof never quite delivers the certificate. Inland at Broadstone, Creekmoor or Canford Heath the same unit sits closer to its declared performance, because the air around it is comparatively still.

Under the mature pines at Canford Cliffs and Branksome Park a third thing happens. The canopy shelters the roof from wind and from sun in equal measure, so heat loss is closer to the lab figure while solar gain is permanently reduced. On those roofs the U-value matters more than usual and the solar control specification matters a great deal less, which is one of the few situations where the right answer costs less rather than more.

What we put in writing

Every quotation names the unit, its declared whole-unit U-value, the plane that figure was declared in, the spacer type and the glass make-up surface by surface. Where a manufacturer’s declaration is the governing document we say so and we do not paraphrase it into a rounder, friendlier number.

Our installation work carries a ten-year workmanship guarantee. It is a workmanship guarantee and it is not insurance backed, and we would rather say that plainly than leave it to be assumed. Glass and coating warranties are the manufacturer’s and some carry conditions about pitch and cleaning. The price is fixed in writing after we have been on the roof, because the kerb detail is the part of this that a photograph cannot show.

To talk through a roof, ring 01202 923272. If you hold two quotations with two different U-values, bring both — the difference is usually one of the three questions above rather than the glass.

Get a fixed quote

Get a fixed quote

Tell us which way your roof faces.

We will come back with a specification, not a catalogue page. If your extension faces south we will tell you the G-value we would fit and why.

  • No pressure, no doorstep sales call
  • We handle the Building Control notification
  • 10-year workmanship guarantee on every installation
  • Installations and replacements across Poole and south Dorset

Prefer to talk it through? 01202 923272