The short answer

Up to whatever maximum the manufacturer declares for that product at that diameter — but the useful limit arrives before the declared one. A tunnel does not stop working at a cliff edge; it fades, and most people reach the point of disappointment while the tube is still technically within specification.

A sun tunnel run from dome to diffuserLight enters at the dome and is reflected down the tube to a ceiling diffuser. Every bend costs reflectance, so a straight short run delivers far more than a long one with turns. Light falls with the square of the diameter.daylightdomeevery bend costs lightceiling diffuser

Two different limits, often confused

The declared maximum is a product statement: the longest run the maker will stand behind for a given tube and diameter, beyond which they make no claims and the warranty position changes. It is a real number, it is published, and we work inside it rather than at it.

The practical limit is about you. It is the length at which the light arriving at the diffuser stops being worth the work, and it depends on the diameter, the tube type, the number of bends, and what you are comparing the result against. A four-metre run into a small internal cloakroom might delight you. The same run into an open hallway with a pale floor might read as nothing much.

What the length is actually costing

Light travels down a tunnel by bouncing off the wall, and every bounce hands over a fraction of what is left. Longer run, more bounces, and the losses multiply rather than add — each one taking its share of a progressively smaller amount.

That is why the fall-off does not feel linear. The first metre costs very little. The fourth costs a great deal more than the first did, because it is working on what three metres already reduced. The principle is set out properly on the reflectivity page, including why we will not give you a percentage for it.

Where the practical limit tends to sit

Run What to expect What we would specify
Under about a metre and a half, straight The best a tunnel gets. Tube type barely matters Whatever fits neatly; spend the money on diameter
Around two to three metres, one deflection Still a genuinely daylit room Rigid tube, and the largest diameter the bay allows
Three to four metres, or two deflections Noticeably softer, and much weaker on dull days Rigid only, largest diameter, and a frank conversation
Beyond four metres, or several turns Often disappointing, whatever the data sheet allows Move an end, change the room, or fit a rooflight instead

Those bands are a guide to conversations, not a specification. The declared figure for your chosen product governs, and a wide rigid tube will hold up over a distance where a narrow flexible one has long since given up.

Bends count against the length

A run is not measured only in metres. Each change of direction concentrates extra bounces into a short stretch and sends everything downstream of it off at a worse angle, so two metres with a right-angle turn in it can behave worse than three metres straight.

When we judge whether a route is too long, we are counting deflections as well as distance. The detail on what each turn costs is on the corner page.

Shortening a run that looks too long

  1. Move the roof end. Usually the freest of the two. Any clear field of covering with a good view of sky will do, and moving it a metre can remove a bend entirely.
  2. Move the ceiling end. Half a metre across a hallway often costs nothing in usefulness and saves a great deal in tube.
  3. Go up a diameter. A wider tube lets light travel further between bounces, which partly buys back what distance took.
  4. Change tube type. Rigid over flexible is the single biggest improvement available on a long run.
  5. Straighten rather than shorten. A slightly longer straight route frequently beats a shorter one with two turns in it.
  6. Consider two smaller tunnels. In a long hallway, two short runs can beat one heroic one, if the roof allows.

The point at which we say stop

The answer that loses us work, given anyway

A sun tunnel is not a substitute for a rooflight where a rooflight would fit. If a route has grown long enough that we are discussing diameter upgrades and rigid tube just to get an acceptable result, the first question is whether the room has a roof plane of its own. If it does, a skylight in that ceiling beats the long tunnel on every measure and removes the routing problem entirely.

Tunnels are for rooms with no roof above them. A long run is justified when there is genuinely no alternative — an internal stairwell, a hallway under a bedroom floor. It is not justified as a way of avoiding a rooflight that would fit.

The Poole factor that shortens every honest answer

Canford Cliffs and Branksome Park, under the canopy

Run length limits assume a dome with a decent view of sky. Under mature pine the dome starts with less to work with, and evergreen cover does not thin out in winter. A run that would be perfectly reasonable on an open roof in Creekmoor can be too long on a shaded roof half a mile from the cliff top, for the same tube and the same diameter.

Needles accumulating on a small dome take another share on top of that. Where canopy is heavy we shorten what we are willing to call an acceptable run, and sometimes say that no run is acceptable and the room wants a different answer.

What we do about it at survey

We measure the true route rather than the straight line, count the deflections, establish the largest diameter your joists and ceiling will take, and check what the dome will see across the year. Then we say whether the run is comfortably inside the product’s declared maximum, near it, or past the point where we would rather fit something else.

Whatever we propose is a fixed written price after survey, naming the product so you can read its declared maximum yourself. Workmanship carries a ten-year guarantee, our own, not insurance backed. Ring 01202 923272.

Get a fixed quote

Get a fixed quote

Tell us which way your roof faces.

We will come back with a specification, not a catalogue page. If your extension faces south we will tell you the G-value we would fit and why.

  • No pressure, no doorstep sales call
  • We handle the Building Control notification
  • 10-year workmanship guarantee on every installation
  • Installations and replacements across Poole and south Dorset

Prefer to talk it through? 01202 923272