Do sun tunnels leak?
A sun tunnel flashed with the right kit for the covering it sits in does not leak. Most reported leaks turn out to be one of two things: condensation forming inside the tube, or a roof opening that was sealed with mastic instead of being flashed at all.
How a tunnel keeps water out
A tunnel does not rely on a seal. It relies on a lapped detail, the same principle that keeps the rest of the roof dry: water arriving from above passes over the top of the flashing, the flashing passes over the covering below it, and gravity does the rest. Nothing is asked to stick permanently to anything.
It is the same principle a rooflight upstand works on, at a smaller scale: the roof sheds water past the opening rather than being sealed against it.
That is why the flashing kit has to match the covering. A skirt designed to dress into a profiled concrete tile behaves quite differently on a flat slate, and neither one suits a thick, irregular stone. Fitting the wrong kit and filling the difference with sealant produces a roof that is watertight on the day and leaking within a few winters, because the sealant is the only thing doing the work and sealant ages.
What actually fails, in order of how often
| Cause | How it shows | Whether it is a leak |
|---|---|---|
| Condensation inside the tube | Drips at the diffuser on cold mornings, clean water | No. A sealing and insulation fault |
| Mortar or mastic instead of a flashing | Water in the loft during driving rain | Yes, and it will recur until flashed properly |
| Flashing not dressed into the covering | Wet timbers on one side of the opening | Yes. Laps are wrong way round or too short |
| Dome seal or gasket failure | Moisture visible under the dome, gradual | Yes, but a component fault rather than workmanship |
| Underlay cut and not dressed | Occasional damp with wind-driven rain | Yes, and it is invisible from outside |
| Something else on the roof | Water tracking along a rafter to the tunnel | Yes, but not the tunnel’s. Water travels |
The last row catches people out regularly. Water entering at a ridge or a chimney runs down the underlay and appears at the first obstruction, which is often the newest hole in the roof. The tunnel gets blamed for a fault that pre-dates it.
Condensation is not a leak, and here is how to tell
- Weather or temperature? If it appears in rain, suspect a leak. If it appears on cold mornings and after showers, suspect condensation.
- Dirty or clean? Water through a roof carries dirt from the covering and stains. Condensate is clear.
- Where is it wet in the loft? A leak wets the timbers and underlay around the opening. Condensation wets the outside of the tube, or nothing at all.
- How fast? A leak in real rain runs. Condensation beads, gathers, drips slowly, and stops.
- Does it track the household? Worse in a week of indoor drying is the giveaway. Rain is indifferent to your laundry.
The full explanation, and the sleeve and seal that stop it, are on the condensation page.
The covering decides the flashing
Around this service area the coverings vary more than people expect, and so does the correct kit. Profiled concrete interlocking tiles across most of the interwar and post-war suburbs take a standard tile flashing. Natural and fibre cement slates take a flat kit with different laps. A flat roof needs a kerb-mounted arrangement and the covering dressed up it, which is a different job again.
Purbeck stone slates are the outlier. Heavy, thick, irregular, laid in diminishing courses, and no standard flashing kit fits one — that roof needs a bespoke detail and heritage constraint often comes with it, which is why it has a sun tunnel be fitted into a Purbeck stone slate roof. The general comparison across coverings is on the flashings page.
Exposure changes what the detail has to survive
Poole is not one exposure, and the flashing follows the zone
Sandbanks, Studland and the harbour mouth. A sand spit with water on both sides and salt-laden wind arriving with no fetch break. Wind-driven rain hits from directions a sheltered roof never sees, so laps and fixings are specified for it and the materials are chosen to survive salt.
Broadstone, Creekmoor, Canford Heath and Ferndown. Sheltered inland, heathland edge, ordinary exposure. Marine-grade specification there is an overcharge, and we will tell you so rather than sell it.
Canford Cliffs and Branksome Park. The risk is not wind but debris: pine needles and leaf litter accumulating around a small dome and in the flashing skirt, holding water where it should be shedding. That is a maintenance condition rather than a defect, and it is worth knowing about before you choose a dome.
What we do on the day to make sure
The covering is lifted rather than broken, the underlay cut and dressed properly rather than slit, the flashing laid so every lap sheds downhill, and the covering reinstated over the skirt. The roof is opened and closed in the shortest window we can manage, and nothing relies on sealant to be watertight.
Inside, the tube is sealed at every joint and at the ceiling collar, which is as much about moisture as about light. A tunnel is a closed run from dome to diffuser and it should be left that way.
If yours is leaking now
Get it diagnosed before anyone proposes replacing it. A tunnel that drips is more often a sealing job than a new installation, and a tunnel that leaks in rain is more often a flashing detail than a faulty product. Both are correctable without a new skylight or a new tube.
We quote a fixed written price after survey, and our workmanship carries a ten-year guarantee, which is our own guarantee and is not insurance backed. To have a wet tunnel looked at properly, ring 01202 923272.
Related reading
1930s Poole semis with internal bathrooms and no wall to reach
The interwar semi built across Parkstone, Winton, Penn Hill and Oakdale has a recognisable problem: a bathroom in the middle…
Adding a light kit so the tunnel works after dark
A sun tunnel goes dark when the sky does. In a bathroom or a hall that had no daylight at…
Are sun tunnels warm or do they lose heat?
A sun tunnel is a hole through your insulated ceiling, so yes, it loses some heat — and a properly…
Broadstone bungalows where the loft void is shallow and wide
Broadstone, Creekmoor and the bungalow runs out towards Corfe Mullen were built low and built wide. Every room sits on…
Can a sun tunnel be fitted in a bathroom?
Yes. A windowless internal bathroom or en-suite is the single most common place a sun tunnel earns its keep, and…
Can a sun tunnel be fitted into a Purbeck stone slate roof?
Yes, but not with a kit. Purbeck stone slates are thick, heavy and laid in diminishing courses, and there is…