What happens if a roof window is fitted too close to the ridge?

The short answer

Four things go wrong and only one of them is a leak. The head flashing runs out of roof above it, so water gets a short cut behind the apron. The ridge ventilation path gets obstructed. On a visible slope it can breach the planning condition that nothing may sit above the highest part of the roof. And it looks wrong from the ground, which is the one you notice first.

A roof window set between rafters in a pitched coveringThe window sits in the plane of the covering between existing rafters. A flashing kit matched to the covering carries water around the frame, and the underlay is dressed to a collar so anything passing the tiles is returned to the outside.roof windowrafterrafterflashing kitcovering

What the head of a roof window needs above it

Water arriving from higher up the slope is carried round the window and back onto the covering below by the head apron, working with the underlay collar behind it. Both are lapped under the courses above, so water running down those courses passes over the flashing and never behind it.

That lapping needs roof to lap into. Too close to the ridge and there is not enough of it: the apron finishes hard against the ridge tiles or under a single short course, the underlay collar has nowhere to be dressed, and the assembly relies on a few centimetres rather than a proper lap.

The failure it produces, and how it shows

It is not usually a dramatic leak. It is intermittent, it arrives in wind-driven rain rather than a steady downpour, and it shows as a damp patch at the head of the reveal or a stain on the ceiling below. People report it as a failed flashing, and the flashing is not failing; it is being asked to work without the covering it was designed to be built into. On the coast it shows sooner: rain driven up a slope by an unbroken south-westerly is exactly what a short head lap cannot handle, which is why the same detail sits unnoticed for years at Broadstone and stains a ceiling in one winter at Southbourne.

The ridge is also where air leaves the roof

In most modern roofs and most upgraded older ones, the ventilation path runs from the eaves, up between the rafters, and out at the ridge. A window crowded up against the apex sits right on top of the exit. Its frame, its trimmers and its insulation collar all take room out of a path that was already narrow, and if that path is choked the moisture-laden air that should be leaving the roof stays in it. The symptom is damp timber and mould at the ridge, reported six months later as an unrelated problem, and it is a great deal harder to trace than a leak.

The planning condition people forget

A rule that applies even when no application is needed

Permitted development for roof alterations on a house comes with conditions, and one is that no part of the alteration may be higher than the highest part of the existing roof. A unit crowded up against the ridge, particularly one standing proud rather than recessed, can breach it. The other condition is the limit on how far the installation may project beyond the roof plane. Neither is a matter of opinion. The full picture is on do roof windows need planning permission.

It looks wrong, and that is a real cost

A roof reads as a composition: a field of courses with a line along the top. A window jammed into the last few courses intrudes on that line, and the eye picks it up from across the street even when it cannot say why. Set the same unit two or three courses lower and it sits within the field instead of fighting the ridge. On a visible front slope in a conservation area that difference is not merely taste; it is the difference between an installation that passes without comment and one that attracts it.

How much room the head actually needs

Covering What the head needs above it Why
Plain tile Several full courses, which on a shallow gauge is a modest distance Small courses mean the required lap is achieved in less vertical roof than any other covering
Natural slate Several courses, more vertical distance than plain tile Deeper courses, and the headlap has to be maintained into the apron
Interlocking concrete tile Fewer courses but the most vertical distance of the common coverings Each course is 300mm or more, so a small number of courses is a large piece of roof
Purbeck stone slate Determined on the roof, course by course Diminishing courses mean the stones near the ridge are the smallest on the roof, so more of them are needed

The rule is the awkward one: the bigger the tile, the further from the ridge the window has to be. On a 1930s roof re-covered in large concrete tile, with a short rafter run to begin with, the band a window can sit in is narrower than people expect.

The opposite mistake is just as easy

Dropping the window too low is the same problem upside down. At the eaves sit the first course, the tilting fillet, the fascia and the ventilation inlet, and the sill apron needs a full course to sit over. Between the two constraints there is a usable band, and on a short slope it can be under a metre of roof, which is why the position is set out on the roof rather than assumed from a plan.

If yours is already too close

  1. Establish whether it is leaking or whether the damp is condensation at the perimeter. The two look similar from inside and are unrelated.
  2. Look at the head detail from outside: how many full courses sit above the apron, and whether a collar was ever formed.
  3. Check the ridge ventilation path is not choked by the frame or the collar.
  4. Where there is enough roof and the detail was simply built badly, the head can often be re-formed and the courses re-laid.
  5. Where there genuinely is not enough roof above it, moving the unit down the slope is the honest answer. What that involves is on moving a roof window.

What we do at survey

We measure the rafter run from wall plate to ridge, establish the gauge, work out how many courses must stay above the head and below the sill, and show you the band that is left. If the position you wanted is outside it we say so before anything is ordered, and explain which of the four problems it would cause. A roof window, a skylight or a recessed conservation rooflight all need roof above them to lap into, and the ridge is where that runs out. Ring 01202 923272.

Get a fixed quote

Get a fixed quote

Tell us which way your roof faces.

We will come back with a specification, not a catalogue page. If your extension faces south we will tell you the G-value we would fit and why.

  • No pressure, no doorstep sales call
  • We handle the Building Control notification
  • 10-year workmanship guarantee on every installation
  • Installations and replacements across Poole and south Dorset

Prefer to talk it through? 01202 923272