Can a roof lantern sit on a flat roof without a kerb?
No. A roof lantern has to stand on an upstand of some kind — either a kerb built on site or a proprietary insulated upstand supplied with the unit. Setting a lantern straight onto the deck puts its frame in the wettest few centimetres of the roof, which is exactly where nothing glazed should sit.
There is no version of this that skips the upstand
People usually ask this for one of two reasons: headroom is tight below and every millimetre counts, or a quote has come in with the kerb as a separate line and it looks like something that could be negotiated away. Neither reason survives contact with how a flat roof works.
A flat roof is not flat. It is laid to a fall, and water travels across it to an outlet. In heavy rain that water is a moving film, and at the low corners it briefly stands. A lantern frame sitting in that film is a lantern frame that will eventually let water past. Lifting the whole assembly clear of it is the entire point of the kerb, and it is the same reason a flat rooflight is set on an upstand rather than bedded onto the membrane.
The four jobs the kerb is actually doing
Not a plinth — a working part of the roof
It lifts the frame out of the wet zone, so the glazing line is never sitting in running or standing water.
It gives the waterproofing something to climb. The roof covering turns up the kerb face and terminates on it, which is what makes the opening watertight before the lantern ever arrives.
It provides a flat, square, level bed. Aluminium frames are not forgiving; a frame bedded across a hollow is a frame that will drip at that point.
It carries the fixings. The lantern is mechanically fixed into the kerb, and the kerb into the trimmed structure below.
A built timber kerb or a proprietary upstand
| Option | What it is | Where it suits |
|---|---|---|
| Timber kerb built on site | Treated timber framed around the trimmed opening, insulated, sheathed and dressed by the roofer | New openings, non-standard sizes, anywhere the height needs to be tuned to the falls |
| Proprietary insulated upstand | A factory-made insulated collar in a fixed size, delivered to suit the lantern | Standard apertures, cold-bridge-sensitive builds, jobs where consistency matters more than adjustment |
| Existing kerb reused | A sound upstand from a previous rooflight, checked for square, level, rot and height | Replacements only, and only after it has genuinely been checked rather than assumed |
Either of the first two is a proper answer. What is not a proper answer is a bead of sealant around a frame laid on the membrane, which is what “no kerb” tends to mean in practice.
How high, and why 150mm is the number roofers work to
Flat-roof waterproofing is detailed to turn up a minimum of 150mm above the finished roof surface at any abutment or upstand. That is the convention the trade works to, and it exists because it takes a realistic view of how far water climbs a vertical face in wind, how deep snow sits and how much a deck can sag over time.
The rule, and where it moves
The 150mm is measured from the finished roof surface, not from the deck — so insulation, boarding and covering all come off it first. And it is measured at the low side. On a roof with a pronounced fall, a kerb that gives 150mm at the high corner can give far less at the low one, which is how an upstand that looks generous on paper ends up marginal on the roof.
Height is not free, and in some of Poole it is looked at
Around the Old Town and the Quay, roofs sit inside a conservation area and are seen from the street and from the water. A tall kerb under a tall lantern raises the whole assembly into view in a way that a flush conservation rooflight does not, and that is a planning conversation with BCP Council before it is a construction one.
Four miles inland in Broadstone or Canford Heath the same kerb height is nobody’s concern. The constraint is local, and it is worth knowing which side of it you are on before the design is fixed.
Where visibility is the issue, the honest alternative is often not a shorter kerb but a different product — see conservation rooflight installation for what sits low in a roof plane by design.
Cold bridging, and the line of condensation on the plaster
A kerb built of bare timber connects warm inside air to cold outside air through a few centimetres of wood. That is a cold bridge, and it shows up as a cold stripe around the reveal, then as condensation on the plaster in that stripe, then as staining. It is one of the most common complaints about older lanterns and it has nothing to do with the glazing.
The fix is to insulate the kerb as part of building it, with the insulation continuous from the roof build-up up and around, so there is no line of untreated timber running from inside to out. A proprietary insulated upstand does this by design; a site-built kerb does it if the person building it treats it as a thermal element rather than a piece of carpentry. On thermal performance more generally, see whether a roof lantern is warmer than a flat rooflight.
What we build, and what we will not do
We build the kerb as part of the installation, insulated, square and checked on the diagonals, with the covering dressed up it and terminated before the lantern goes on. On a replacement we will reuse a sound existing kerb and say so, because charging to rebuild something that does not need rebuilding is not a service.
Where we say no
We will not set a lantern or a skylight straight onto a deck, and we will not reuse a kerb that is out of square, soft, or too low for the covering to be dressed properly. If that is what a job needs to come in at a lower figure, we are the wrong firm for it.
Our work carries a ten-year workmanship guarantee, which is a workmanship guarantee and not insurance backed. The price is fixed in writing after the roof is measured. Ring 01202 923272.
Related reading
Can a roof lantern be fitted in winter?
Yes. Winter changes how the working day is organised, not whether a roof lantern can be installed. Cold is a…
Can a roof lantern be made to open?
Yes, but it is decided at order, not afterwards A roof lantern can be made to open. Most systems offer…
Can a roof lantern go on a pitched roof?
Not onto the slope itself. A roof lantern is designed to stand on a level kerb, and a pitched roof…
Can a roof lantern go over a garage conversion?
Frequently yes — but the garage decides, not the lantern Garage conversions are one of the better places to put…
Can one cracked pane in a roof lantern be replaced on its own?
Normally yes, and that is a designed-in advantage of the format A roof lantern is assembled from a frame, a…
Do gulls off Poole Harbour damage a roof lantern?
Rarely the glass. Reliably the drainage and the finish Gulls do not generally break roof lantern glass. Overhead glazing is…