Ridge bar cold bridging and the drip you keep wiping off the sill

How to tell a leak from condensation on a roof lantern, why the ridge is the coldest line in the assembly, and which component to fix before anyone quotes for replacement glass.

Section through a roof lantern on a kerbA roof lantern is a pitched glazed structure standing on a kerb above a flat roof. The pitch sheds water and debris and distributes light; it is not a flat rooflight with a hat on.ridge barglazing barkerbflat roof deckpitch sheds water

You have been wiping the same 200mm of sill since October

It is always the same spot. One end of the lantern, usually the end nearest the ridge, and usually the side of the room that gets the least sun. Cold mornings are worse than wet ones. It dries up completely in April and comes back in the second week of November, and by then you have half-convinced yourself the roof is leaking.

In most cases it is not. A drip that behaves like a season rather than like weather is condensation, and condensation on a roof lantern nearly always traces back to one component running colder than everything around it. On a well-built lantern that component is usually the ridge.

This matters because the two problems have opposite fixes. A leak is repaired by making something more watertight. Condensation is not — you can seal a cold bridge perfectly and it will still run with water, because the water is arriving out of the air inside your own house.

Telling the two apart without getting on the roof

You can settle this yourself in a fortnight of ordinary weather. Almost every distinguishing feature is about timing rather than location.

What you observe Points to a leak Points to condensation
Timing against rain Appears during or shortly after rain, stops when it dries Appears on cold clear mornings, often with no rain at all
Timing against the year Any month, whenever the weather is right for it Roughly November to March, absent all summer
Where it starts A defined point, often with staining spreading from it A line or a band along the coldest edge, no staining
The water itself May carry dirt, grit or a tint from what it has run over Clean, clear, no residue when it dries
Response to the room Unaffected by cooking, drying washing or closing the door Noticeably worse after a bath, a wash load or a closed-up weekend away
Response to wind direction Often only on a driving south-westerly Indifferent to wind direction; follows temperature

What a thermal break is, and what it is not

Aluminium is an excellent conductor. That is exactly what you want in a saucepan and exactly what you do not want in a frame with warm air on one side and a February night on the other. A solid aluminium bar running from outside to inside would sit at close to outdoor temperature on its internal face, and every rooflight of that construction would run with water all winter. Early ones did.

A thermally broken bar solves it by being two separate aluminium sections held together by low-conductivity strips — usually polyamide — running the full length. The outer section is allowed to be cold. The inner section, isolated from it, stays much closer to room temperature. Nothing conducts straight through.

The phrase “thermally broken” on a quotation does not tell you whether the break is continuous, how deep it is, or whether it survives at the junctions. That is the part that decides whether you get a drip, and it is worth asking about specifically rather than accepting the label.

Why it is the ridge that gives out first

A lantern’s rafters are straight runs of extrusion, and a straight run is the easy case: the break is extruded into the profile and it is continuous from end to end by definition. The ridge is not that. It is where every rafter arrives from a different direction, where the geometry changes, and where the assembly has to be mechanically joined rather than simply cut to length.

So the ridge is where a break gets interrupted. A through-fixing that catches both the inner and outer sections shorts the break at that point. A ridge capping that touches cold metal outside and warm metal inside does the same. A hip end, where several rafters converge on one point, concentrates the problem still further. None of these are visible once the lantern is assembled, and none of them show on the thermal figures for the bar itself, which are quoted for the straight section.

Warm air also helps. The warmest, wettest air in the room is the air that has risen, and in a room with a pitched glazed roof over it, the place that air collects is the apex. The coldest line in the assembly and the wettest air in the house end up in contact with each other, which is a poor combination by design.

Ridge bar cold bridging and the drip you keep wiping off the sill
The same lantern after dark, seen from the garden.

The three numbers behind every winter drip

Condensation is arithmetic, not bad luck

Water leaves the air and lands on a surface when three things line up: how much moisture is in the room, how warm the room is, and how cold that particular surface is. Together the first two give a dew point — the temperature at which that air can hold no more. Any surface below it collects water. Any surface above it stays dry.

That is why the fix has three possible routes rather than one. Take moisture out of the room, raise the surface temperature of the cold component, or accept the condition and manage where the water goes. Building Control assessments of thermal bridging use a temperature factor for exactly this reason — a criterion in the region of 0.75 is what is commonly applied to dwellings — and it is a measure of how far a junction’s inside surface drops below room temperature, not of how much heat is lost.

It also explains something people find counter-intuitive: upgrading the glass on its own can make a ridge drip worse. Better glass means the room holds its heat, so the room runs warmer and wetter, while the ridge — unchanged — stays exactly as cold as it was. The coldest surface has not moved but the dew point has risen to meet it.

Where the cold bridge actually is

Before anyone blames the ridge bar, the other candidates deserve a look. Several are cheaper to fix and two of them are more common.

Component How it bridges What resolves it
The kerb A timber box left hollow, so the perimeter of the opening is uninsulated all the way round Insulating the kerb as it is built, and continuing the insulation line up to meet the frame
The internal reveal Plasterboard returned straight onto cold structure with no insulated backing Insulated reveal board and a continuous vapour control layer behind it
Glazing unit spacer An aluminium spacer bar around the perimeter of each pane, cold to the touch at the edge A warm-edge spacer specified at order; it cannot be changed afterwards
Ridge bar and capping Fixings or cappings connecting the cold outer section to the warm inner one A ridge detail whose break is continuous through the junction, specified rather than assumed
Hip or corner nodes Several bars meeting at a point where the break geometry is hardest to maintain Manufactured node components rather than site-fabricated junctions

A drip that runs along the whole ridge is a ridge problem. A drip that appears only at the ends of each pane, on every pane, is almost always the spacer. A drip on the plaster rather than on the frame is the reveal or the kerb. The pattern names the component.

The room under the lantern is half the problem

Most lanterns go over the room that generates the most water vapour in the house. A kitchen-diner produces moisture from cooking, from a dishwasher, from a kettle, from washing hung on an airer at the far end, and from the people sitting in it. Then the extension gets its own door, that door gets closed to keep the heat in, and the room’s moisture has nowhere to go but up to the coldest surface in it.

Two habits make a measurable difference before any building work is considered: run the extract while cooking and for a while afterwards rather than only during, and do not dry washing under the glass. Ventilation is a subject in its own right and there is a separate guide on trickle vents and the Part F argument in lanterns, so it gets one sentence here.

The reason it belongs on this page at all is that a ridge cold bridge and a wet room are the same fault seen from two ends. Fixing the ridge in a room that never ventilates buys you a smaller drip somewhere else. Ventilating a room whose ridge is shorted out by a through-fixing does not fix the ridge.

Ridge bar cold bridging and the drip you keep wiping off the sill
The pitch throws daylight sideways, lighting the back wall rather than only the worktop.

What actually works, in the order worth trying it

  1. Confirm it is condensation. Two weeks of notes against the table above. A repair to the wrong problem is worse than no repair, because it convinces you the diagnosis was right.
  2. Reduce the moisture load. Extract fan used properly, washing dried elsewhere, internal doors not sealing the room shut for days. This is free and it moves the dew point down.
  3. Warm the surface. A room that is heated evenly, with air moving past the glazed pitch rather than sitting still beneath it, keeps the internal face of the frame closer to room temperature.
  4. Insulate the reveal and the kerb. If the drip is arriving onto plaster rather than off metal, this is the fix, and it is internal work rather than roof work.
  5. Get the ridge detail examined. Not the lantern in general — the ridge specifically, for through-fixings, capping contact and continuity of the break at the node.
  6. Replace the component, not the lantern. On many systems the ridge assembly and its capping can be changed without taking the whole skylight out. That is a far smaller job than a full replacement and it should be priced first.
  7. Replace the unit only when the frame is the fault. If the bars are not thermally broken at all — common on pre-2000 lanterns — no amount of reveal work will cure it, and the honest answer is a new rooflight.

The replacement question, answered honestly

Poole has a large stock of 1990s and 2000s glazing reaching the end of its life, and a proportion of it was never thermally broken in the first place. On those units the drip is not a defect, it is the design working as it always did, and it will not be argued away with sealant or a dehumidifier. The fix is a frame with a continuous break, a warm-edge spacer and a ridge detail that holds the break through the junction.

On a lantern from the last fifteen years the answer is usually much smaller. We look at where the water starts, in what pattern, at what time of year, and we say which of the five components in the table above is doing it. Quite often that ends in an insulated reveal and a ventilation habit rather than a quotation for glass.

What you get from us in writing

A ten-year workmanship guarantee on our installation work, stated plainly as a workmanship guarantee and not insurance backed. A fixed written price after the roof has been surveyed — never estimated from a photograph, and never a range that moves once work starts. And a named diagnosis rather than a replacement quote, including the cases where the honest finding is that your lantern is sound and the room needs ventilating.

If you have been wiping the same patch of sill since autumn, ring 01202 923272 and describe when it happens rather than where — the timing is what identifies it. The wider picture sits on the roof lantern installation page, and the related question of how rainwater is handled inside the bars is covered in how glazing bars shed water into the kerb.

Get a fixed quote

Get a fixed quote

Tell us which way your roof faces.

We will come back with a specification, not a catalogue page. If your extension faces south we will tell you the G-value we would fit and why.

  • No pressure, no doorstep sales call
  • We handle the Building Control notification
  • 10-year workmanship guarantee on every installation
  • Installations and replacements across Poole and south Dorset

Prefer to talk it through? 01202 923272