Will a rooflight meet current Part L requirements?
Almost certainly, as a product. Any competently made rooflight sold for the UK market clears the limiting standard for a replacement, which is 2.2 W/m²K for the whole unit declared in the vertical plane. But Part L does not test the unit in isolation — it tests the work — and a compliant skylight can sit in a job that does not comply, which is where almost all the trouble comes from.
The unit is not the thing being examined
People ask the question as though a rooflight carried a pass or a fail stamped on it. What it carries is a declared figure. Whether that figure is good enough depends on what you are doing with it, and the rest of the compliance — insulation continuity at the kerb, ventilation provision, glazed area limits, safety glazing — belongs to the installation rather than the product.
Which test applies to you
| What you are doing | What has to be shown | How hard it usually is |
|---|---|---|
| Swapping a failed unit like for like | The new rooflight meets the limiting standard and is no worse than the one it replaces | Straightforward. A declaration and a certificate, no calculation |
| Putting a new rooflight into an existing roof | The same limiting standard, plus the opening detailed so the insulation and air barrier stay continuous | Straightforward on the glass. The kerb detail is where it is won or lost |
| A new extension | Elemental standards for each new element, and the total glazed area within the allowance for the new floor area | Easy until the glazing is generous, then it needs a calculated route |
| A new dwelling | Whole-dwelling target rates from a notional specification, with limiting values as a backstop | A full calculation, in which the rooflight is one input among many |
How the calculation itself consumes a skylight — area, declared U-value, g-value, orientation, overshading, frame factor — is set out on Part L, SAP and how a rooflight is counted.
The figure, and the catch inside it
2.2 W/m²K is a limit rather than a target, and it is declared as though the unit were upright even though it will spend its life lying at a shallow pitch. Lying down the cavity convects more freely, so the installed behaviour is a little worse than the declaration. That is a universal convention rather than anyone’s trick, and it is one good reason to specify comfortably clear of the limit rather than at it. What the figure covers and omits is on what a rooflight U-value covers.
Four ways a compliant rooflight ends up in non-compliant work
- No declaration. A unit with no traceable manufacturer’s figure for the actual product is not evidence of anything, whatever the brochure says.
- A thermal bypass at the kerb. Insulation stopped at deck level and a bare upstand conducting heat out. The unit passes; the junction does not.
- Too much glass in an extension. A run of rooflights plus bifold doors over the area allowance pushes the job onto a calculated route that nobody budgeted for.
- Ventilation removed. Replacing a ventilated unit with a sealed one without providing equivalent background ventilation fails a different approved document and causes condensation as well.
Ask for these three things in writing
Everything you need fits on one page
The declared whole-unit U-value for the specific rooflight, attributed to the manufacturer, in the vertical plane — not a range for a product family.
The compliance route the work falls under, named before the job starts, so nobody discovers at second fix that a calculation is needed.
The certificate at the end, either a building control completion certificate or a competent person scheme certificate. It is asked for when the house is sold, and its absence is a conveyancing problem years later.
Where it is decided around Poole
Three authorities cover this service area. BCP Council for Poole, Bournemouth, Christchurch and their suburbs. Dorset Council for Wareham, Swanage, Corfe Castle, Wimborne, Dorchester, Weymouth and the Purbeck area. New Forest District Council for Lymington, Brockenhurst, Ringwood and New Milton. A private approved inspector can be used instead of the local authority on most work, which changes who inspects but not the standard.
Building regulations are separate from planning. A roof in a conservation area, on a listed building, in the Dorset National Landscape or on the Jurassic Coast may need both, and planning is assessed on merit and never assured.
What we do about it
We name the route, put the manufacturer’s declared figures on the quotation as theirs, detail the kerb so the insulation and the air barrier stay continuous, and tell you which authority signs the work off.
We will not tell you a skylight will pass a calculation we have not seen, and we will not quote a saving or a payback. Our installation work carries a ten-year workmanship guarantee — a workmanship guarantee, plainly, and not insurance backed — with a fixed written price after survey. Ring 01202 923272 and describe the work; which of the four rows above you are in takes a minute to settle and decides everything else.
Related reading
Argon and krypton fills matter less than the brochure suggests
The cheapest line on the specification is usually the loudest Argon fill appears on almost every glazing quotation in the…
Condensation on the inside of the glass is a humidity problem
A week with a hygrometer settles it faster than an argument Almost every conversation about a wet skylight starts in…
Do rooflights cause draughts?
A correctly installed one should not. When a skylight is blamed for a draught it is almost always one of…
Do rooflights help with damp in a room?
With one kind of damp, and only if it opens. A skylight does nothing whatever for rising or penetrating damp…
Do rooflights lose more heat than walls?
Per square metre, yes, and it is not close. Any glazing loses heat several times faster than the insulated fabric…
Do rooflights make a room colder in winter?
No, not a modern one. A well-specified rooflight in a well-detailed opening adds heat loss in the same way any…