Energy Efficient Rooflights and Skylights in Poole
How U-value, g-value, coatings, gas fill and the kerb detail decide whether a rooflight saves energy in Poole, and which glazing build-up each of the town's four exposure zones actually needs.

A rooflight is asked to do two opposite things
Every energy question about a skylight ends at one conflict: you want the glass to hold heat in during February and keep heat out in July. Different jobs, different numbers, and the glass best at one is rarely best at the other.
The U-value is heat lost: watts per square metre for each degree of difference between inside and out, and lower is better. The g-value, or solar factor, is the share of the sun’s energy the glass passes, and lower means a cooler July and a dimmer, colder January. They pull against each other, because the coatings that push the g-value down take daylight with them, and solar gain through a roof is free heating in winter and an unwanted load in summer.

| The question | U-value | g-value (solar factor) |
|---|---|---|
| What it measures | Heat conducted out through the whole unit | Solar energy passing in through the glass |
| Typical on a rooflight | 1.0 to 1.4 W/m²K for a good argon-filled double, declared vertically | Near 0.6 clear, around 0.4 solar control, around 0.3 high performance |
| What the Regulations set | 2.2 W/m²K limiting standard for a replacement | No fixed domestic figure: a comfort decision, not a compliance one |
The 2.2 figure, and what it commits you to
Replacing a rooflight in an existing home in England is controlled work under Part L, and the limiting standard is 2.2 W/m²K. It gets quoted at homeowners as a target. It is not: it is the worst you are allowed to fit, and most sealed units we specify sit well inside it. Two details behind it decide whether a quote is comparable with anyone else’s.
The rule, and where it bites
The rule: a replacement rooflight must meet 2.2 W/m²K, and for that standard the U-value is assessed in the vertical plane. It is a whole-unit figure covering glass, spacer and frame, and on a pitched or domed unit it is based on the developed area of the glazing rather than the hole in the roof. BCP Council Building Control, or an approved inspector, signs it off.
Where it bites: the same unit tested lying near-horizontal performs worse than it does standing up, because a cavity on its back convects far more freely than one on edge. Ask which plane a figure was declared in, and whether it is whole-unit or centre-pane, because centre-pane is the flattering one: it leaves out the spacer and the frame, which is exactly where a rooflight loses heat.

Coatings, argon, and where the money should go
A low-emissivity coating is a layer of silver a few atoms thick, close to invisible, and it does more for the U-value than anything else in the unit: it reflects heat radiated from the room back into the room instead of letting it cross the cavity. An uncoated air-filled double sits near 2.8 W/m²K at the centre pane. Add a soft-coat low-e and an argon fill and the same build-up lands around 1.1 to 1.2.

| Surface | Where it is | What belongs there |
|---|---|---|
| Surface 1 | Outer face, against the weather | Nothing, or a self-cleaning hard coat, the only one durable enough to be exposed |
| Surface 2 | Outer pane, cavity side | Solar control, catching the sun before that energy is inside the cavity |
| Surface 3 | Inner pane, cavity side | The low-e coat, in a heating climate like ours. It keeps room-side heat on the room side |
| Surface 4 | Inner face, against the room | Nothing we specify. Where retrofit film ends up, on the wrong side of the glass |
Argon slows the convection loop across the cavity, worth roughly a couple of tenths of a watt per square metre per degree: real, and modest next to the coating. It counts for more overhead than in a wall, where the cavity stands on edge. How long it stays is the fair question. Units are filled to around ninety per cent argon at manufacture, and the European standard permits a leakage rate of no more than one per cent a year, so a compliant unit still holds most of its fill after twenty years. One losing gas faster is losing it through the edge seal that will later admit moisture, so misting shows long before the heat does.
- The low-e coating. The biggest single move on heat loss, and the cheapest performance in the unit.
- The edge seal and spacer. A dual-sealed unit with a warm-edge spacer holds its gas and lifts the glass edge temperature, which is where condensation starts on a rooflight. The fill itself is cheap and pointless behind a poor seal.
- The frame’s thermal break. An excellent unit in a frame with a cold metal path through it still runs a wet line round the perimeter in January.
At Sandbanks and the harbour mouth that order changes and the edge seal goes to the top: a unit that fails at its edge after eight years has thrown away whatever you paid for the glass inside it.
Solar control glass, or film stuck to the ceiling
When a room is already cooking, the cheap suggestion is film on the inside of the existing glass. It is not the same product. A coating on surface 2 reflects solar energy while it is still on the cold side of the cavity; a film on surface 4 largely absorbs it, on the room side, where much of the heat it captures is re-radiated into the room it was meant to protect.

| What matters | Coating in the sealed unit | Film on finished glass |
|---|---|---|
| How it works | Reflects the energy before it enters the cavity | Absorbs much of it, then sheds that heat both ways |
| Effect on the glass | None. The unit is designed around it | Raises pane temperature and thermal stress; some films exclude sealed or toughened units |
| Warranty | Covered by the sealed unit maker | Filming a sealed unit commonly ends its warranty. Check before, not after |
Film has a place on a sound unit you are not ready to replace, as a mitigation rather than a specification.
Triple glazing, and why we rarely specify it overhead
Triple glazing is excellent in the right building. On a domestic rooflight in Dorset it usually is not, for specific reasons rather than a matter of taste.
| What changes | Good double: low-e, argon, laminated inner | Triple |
|---|---|---|
| Heat loss | Comfortably inside the 2.2 limiting standard | Better again, but a fraction of the step from single to double |
| Daylight | Two panes, two coated surfaces at most | More glass and more coatings, each taking a slice of the light |
| Weight and frame | Glass weighs about 2.5kg per square metre per millimetre of thickness | A third pane adds roughly 10 to 15kg per square metre overhead, and a deeper frame designed for it |
| Lying near-horizontal | One cavity to keep still | Two cavities, both convecting more freely at low pitch, and the second returns less than the first |
| Outer pane on a clear night | Occasional dew in autumn | More often and for longer: so little heat reaches it that it chills below the air |
That last line is the one people are least prepared for. Condensation on the outside is evidence the unit is working, not that it is faulty: on a clear autumn morning at Canford Heath a high-performance skylight can be milky until the sun clears it.
Triple earns its place on a large glazed area, or in a structure designed for the weight from the outset. Bolted onto an ordinary domestic kerb it is money that would do more good in the kerb insulation.
Which way the roof faces, and how steeply
Orientation is the first thing people ask about, and the answer depends almost entirely on pitch, which is the thing they do not mention. A flat rooflight at three to five degrees barely has an aspect: it faces the whole sky dome and takes the midsummer sun close to square on at midday whichever way the house is turned. A roof window at thirty to forty-five degrees has a strong aspect, and west is its worst case: the late sun is low, hits that pitch nearly head-on, and arrives when the room has been warming all day.
The rule, and the exception
The rule: the flatter the unit, the less its orientation matters and the more solar control earns its cost. The steeper the unit, the more aspect decides everything, and west-facing steep glazing is the case to specify hardest against.
The exception: north-facing roofs, and anything under permanent shade. There is no solar load worth paying to block, so solar control glass buys nothing but a darker room. That budget goes into the U-value and light transmission instead.

Poole is four different climates for a piece of glass
The town wraps around the second largest natural harbour in the world, and within four miles the conditions a piece of glass lives in change completely.
The pine canopy at Canford Cliffs and Branksome Park changes the sums, and the trees are not going anywhere. Tree preservation orders mean the mature pines stay, and pine is evergreen: it shades the roof in August and just as thoroughly in January. A deciduous canopy drops its leaves exactly when you want the sun back; a pine canopy does not, so heavy solar control glass under those trees buys shade twice and is paid for with a dark room all winter. That roof wants light transmission, a sound U-value and a self-cleaning outer pane, because resin and needle fall cut daylight more than owners expect.
Sandbanks and the harbour mouth are the opposite problem: salt-laden wind with no fetch break is hard on edge seals and fixings, and it strips heat off the outer pane faster than a sheltered site does, so an exposed roof never quite delivers the lab figure. The Quay and Poole Old Town sit behind land that breaks the prevailing south-westerly, so the constraint there is appearance rather than salt, and conservation area status makes a mirrored or tinted coating the kind of detail that gets noticed. Broadstone, Creekmoor, Canford Heath and Upton are ordinary inland exposure, and ordinary is a specification rather than an insult.

| Roof aspect and pitch | Exposure zone | Glazing build-up we specify | What it is optimised for |
|---|---|---|---|
| Flat or low pitch, any aspect | Zone 1: Sandbanks, the harbour mouth | Toughened outer, solar control on surface 2, low-e on surface 3, warm-edge dual-sealed argon cavity, laminated inner, A4 stainless fixings | Summer gain first, then seal life: the unit’s life here is decided at its edge |
| South or west, pitched 30 to 45 degrees | Zone 2 or 4: Old Town, the Quay, Broadstone, Creekmoor, Canford Heath | Neutral solar control near a 0.4 g-value, low-e on surface 3, argon fill, laminated inner | Cutting the afternoon peak without tinting the room |
| North, or heavily shaded, any pitch | Any zone | Clear low-e double, argon fill, no solar control, highest light transmission | Daylight and heat retention. No solar load worth blocking |
| Any aspect under mature pine | Zone 3: Canford Cliffs, Branksome Park | Lightly coated low-e double, self-cleaning outer pane, argon fill, laminated inner | Recovering the daylight the canopy and debris take, all year |
Glass overhead: the laminated inner pane is not an upgrade
Anything glazed above a place where people stand is overhead glazing, and Part K of the Building Regulations covers what happens if it breaks. Toughened glass is strong, but when it fails it dices into thousands of fragments and those come down. Laminated glass has a plastic interlayer bonded between two plies: break it and the pieces stay stuck to the interlayer, and the sheet stays in the opening.
The default we do not vary, and what it changes on a replacement
The default: a toughened outer pane and a laminated inner pane on every rooflight we fit, at every size, over every room. Toughened outside because it takes hail, maintenance traffic and thermal stress. Laminated inside because that is the pane above your head, and the interlayer stops effectively all the ultraviolet as well.
On a replacement: a great many rooflights fitted across Poole in the 1990s and 2000s are toughened on both faces, and replacement is the moment that gets corrected. A like-for-like quote that quietly keeps a toughened inner pane is cheaper for a reason.

The kerb is where the heat actually leaves
You can specify a 1.1 W/m²K unit, fit it properly, and lose much of the benefit in the 150mm of timber it stands on. The kerb is a continuous ring of structure standing proud of the insulation line, and if the insulation stops at the deck a cold band runs round the whole opening.
The arithmetic is unkind to small units. A 600 by 600 rooflight carries about 6.7 metres of perimeter junction for every square metre of glass; a 2 metre by 1 metre unit carries 3. The smaller the skylight, the more of its heat loss happens at the edge. The cure is to carry insulation up the outside of the kerb and return it over the top to meet the frame, so the thermal line runs unbroken. Get that wrong and the first cold snap tells you, usually as a phone call reporting a leak.
| Where the water is | When it shows | What it actually is | What fixes it |
|---|---|---|---|
| Room face of the glass and lower frame | Cold mornings after a still clear night, worst in kitchens and bathrooms | Condensation: warm moist air meeting the coldest surface in the room | Ventilation and extraction, plus insulating kerb and reveal. Not a new rooflight |
| Evenly down the reveal, all the way round | Through the winter, with no relation to rain | A cold bridge at the kerb, below dew point along its whole length | Insulate the upstand and return it to the frame |
| Outside face of the outer pane | Clear autumn mornings, gone once the sun is on it | Dew on a unit that is working: so little heat escapes that the pane cools below the air | Nothing. It is evidence, not a fault |
| At one point, with a stain and a growing tidemark | During and after driven rain, often from one wind direction | A leak: the upstand detail, the covering termination or a fixing | Find the detail and repair it. Ventilation does nothing here |
What the survey settles
We do not specify glazing from a photograph, or quote a U-value down the phone as though every roof in Poole were the same.
- The exposure zone, named in writing. Which of the four Poole zones you are in, and therefore the frame finish, the fixing grade and how hard the edge seal has to work.
- Aspect, pitch, shade and the room underneath. A pine canopy and a neighbour’s gable are not the same kind of shade, and a kitchen adds moisture and internal heat that a hallway does not.
- The U-value, with its plane and its scope. Vertical or horizontal, whole unit or centre pane, both stated so you can compare our quote with anyone else’s.
- The g-value and the light transmission together. Either alone tells you nothing. What you want is the most daylight per unit of solar heat.
- The make-up, surface by surface. Which coating on which face, spacer type and gas fill.
- The kerb detail and the approvals route. Where the insulation line runs, then Building Control through BCP Council or an approved inspector, and whether conservation area status applies.
If the glass is fine and the kerb is the problem, that is what the survey will say, even though insulating an upstand is a far smaller job than replacing a skylight.
What we promise, and what we will not claim
This is a new firm.
The two things we put in writing
A ten-year workmanship guarantee on our installation work. It is a workmanship guarantee and it is not insurance backed, which we say plainly because the difference is real. Sealed units carry their own manufacturer warranties, handed over with the declared figures for what was fitted.
A fixed written price after survey. Not a range and not a guide. If something genuinely unforeseeable appears once the roof is open, soft deck under an intact covering being the usual one, we stop, show you, and price that repair separately before going on.
We install and replace rooflights, roof windows, lanterns and flat skylights across Poole and about thirty miles around it; we are not a general roofing firm. If you want to know which exposure zone your address falls in, or whether a unit you have been quoted is declared vertically or horizontally, ring 01202 923272 and ask. We will give you the zone on the phone; the specification needs the roof measured first.
In this section
Argon and krypton fills matter less than the brochure suggests
The cheapest line on the specification is usually the loudest Argon fill appears on almost every glazing quotation in the…
Condensation on the inside of the glass is a humidity problem
A week with a hygrometer settles it faster than an argument Almost every conversation about a wet skylight starts in…
Do rooflights cause draughts?
A correctly installed one should not. When a skylight is blamed for a draught it is almost always one of…
Do rooflights help with damp in a room?
With one kind of damp, and only if it opens. A skylight does nothing whatever for rising or penetrating damp…
Do rooflights lose more heat than walls?
Per square metre, yes, and it is not close. Any glazing loses heat several times faster than the insulated fabric…
Do rooflights make a room colder in winter?
No, not a modern one. A well-specified rooflight in a well-detailed opening adds heat loss in the same way any…
Do solar control rooflights make a room darker?
Slightly. Every solar control coating takes some daylight with the heat, because it is impossible to remove energy from sunlight…
Does an inland Poole roof need the same solar control as the harbour?
For the glass, usually yes. Solar control follows the sun — pitch, aspect, glazed area and what shades the roof…
Does BCP building control check rooflight U-values?
Where the work is notifiable, yes — but as a paper check rather than a measurement. Building control wants the…
Does external shading beat an internal blind on a rooflight?
Yes, and the margin is large. External shading intercepts solar energy before it reaches the glass, so most of what…
Does heavy tree cover change the rooflight glass I need?
Yes — and usually towards a simpler, cheaper specification rather than a more elaborate one. Heavy cover has already done…
Does rooflight glass block UV and stop furniture fading?
It blocks almost all of the ultraviolet, and it will not stop fading. Those two statements sit together because ultraviolet…