Underlay, drape and the gap that stops water tracking behind a window
How roofing underlay, its drape and the collar around a roof window form the second line of defence, and why a stain a metre away is usually this.
The wet patch is rarely where the water got in
Somebody rings about a damp corner of plasterboard a metre to the left of their roof window. The flashing looks immaculate. The tiles are sound. Nothing about the outside of the roof suggests a problem, and yet in the right sort of weather a stain appears, dries out, and comes back a fortnight later.
Almost every time, the answer is underneath. Water that gets past the covering, and some always does, is supposed to land on the roofing underlay and run down it to the eaves. A roof window interrupts that layer. If the interruption is handled properly the water is caught, steered round the frame and put back onto the tiles below. If it is not, the water runs behind the window, along a rafter, and emerges wherever gravity and the plasterboard agree to let it. This page is about the layer nobody sees again once the job is closed up, and it is behind most of the skylight callouts we attend where the flashing turns out to be blameless.
What the underlay is for when the tiles are already waterproof
They are not waterproof. A tiled or slated roof is water-shedding, which is a different claim: it sheds the overwhelming majority of what lands on it using lap, pitch and gravity. In driving rain, in wind that lifts a tile edge, in snow melting under a covering, and through capillary action between two slates, a proportion gets past. On an exposed slope in a south-westerly gale that proportion is not trivial.
The underlay catches it. Any roof built or re-covered in the last seventy years will have something under the battens. What has changed is what that something is made of, and how it is expected to behave around an opening.
Drape is not slack, it is a channel
The sag that is doing a job
Underlay is laid with a deliberate drape between the rafters, typically in the order of 10mm to 15mm below the batten line at mid-bay. That sag turns each rafter bay into a shallow gutter, so water landing on the membrane runs down the middle of the bay rather than spreading sideways and finding the nail holes along the rafter tops. Pulled drum tight, an underlay does not drain; it holds a film of water against the battens and the fixings.
The exception is a supported system. Where the membrane is laid over boarding, sarking or a counter-batten arrangement that supports it fully, drape is neither wanted nor possible, and the drainage route is designed differently. Check which system you have before assuming a taut membrane is a fault.
Too much drape is its own problem. A membrane sagging 40mm or more touches the insulation below it in a cold roof, wicks, and stops draining. It also flaps in wind, and a flapping underlay abrades against batten edges until it splits.
Bitumen felt and breathable membrane are not interchangeable
What is under your battens changes how the window perimeter must be detailed, and on a re-covering it changes what the loft below needs.
| Underlay type | Typical roofs | Behaviour | What it means at a window |
|---|---|---|---|
| Reinforced bitumen felt | Roofs covered or re-covered from the 1950s to the 1990s | Impermeable to vapour. Stiff when new, brittle and prone to tearing with age | Cuts badly, will not dress neatly to a frame. Usually patched with a proprietary collar rather than folded |
| Vapour permeable membrane | Most work from roughly the 2000s onward | Sheds water, lets vapour out. Light, tough, foldable | Dresses and tapes to a collar cleanly. The detail manufacturers design for |
| Air-open permeable membrane | Specified where unventilated cold roof build-ups are intended | Relies on airflow through the membrane as part of the moisture strategy | The perimeter seal must not blind it. Sealing the wrong face changes the roof’s whole moisture behaviour |
| No underlay at all | Pre-war roofs never re-covered, torching lost or failed | The covering is the only barrier | A local area of new membrane is formed around the opening. Honest, and it should be priced in from the survey |
That last row is common on older stock around the Old Town, Parkstone and the Purbeck villages, and it is one of the things a survey in the loft is for. A quote written without knowing whether there is an underlay is a quote with a hole in it.

The cut: an envelope, never a cross
Once the opening is framed, the membrane spanning it has to be opened. The instinct is a cross cut, four flaps folded back. That leaves cut edges pointing uphill at the head of the opening, and a cut edge facing uphill is a scoop. Water running down the bay arrives, meets the edge, and goes under.
The correct approach is an envelope: the membrane is cut so that the head flap folds up over the head trimmer and is fixed on its upper face, the side flaps wrap the trimming rafters, and the bottom flap is dressed down over the sill trimmer and out onto the covering below. No cut edge faces the flow. Every lap runs the way the water runs. It is the same discipline as flashing, applied a layer lower and with nothing to hide behind.
The flaps are then stapled or taped to the sides of the timbers, not to their top faces where the battens and the frame brackets will land. A staple through the top face puts a hole exactly where water passes.
The underlay collar, and the gutter it forms
Manufacturers sell a collar for this, and it is the piece most often left in the van. It is a shaped membrane or foil-faced apron that joins the roof underlay to the window frame all the way round and forms a defined drainage path, so that water arriving from above is split at the head, carried down both sides in a lined channel, and discharged onto the covering below the sill.
- Frame fixed and squared first. The collar is dimensioned to the frame, so nothing is cut until the frame is in its final position.
- Head section on, lapped under the roof underlay above. The membrane from up the slope must sit on top of the collar, not the other way round.
- Side sections next, lapped under the head section and over the sill section. Bottom of the lap always downhill.
- Sill section dressed out over the covering below. The water has to leave the assembly onto tiles or slate, in daylight, not into a batten cavity.
- Laps taped where the system calls for it. In severe exposure that is not an upgrade, it is the specification.
- Only then the battens, and only then the flashing kit. A collar fitted after the flashing is a collar fitted for the photograph.
The vapour control and insulation collars that go on the inside face are a separate set of components with a separate order of work, and they belong to a different conversation; they are not substitutes for the underlay collar and they do not do its job.
Getting the water past the window and out
A drainage channel is only useful if it leads somewhere. The collar delivers water to the two rafter bays either side of the window, and those bays have to carry it down to the eaves and out over the fascia into the gutter. That means the underlay at the eaves has to be dressed into the gutter, over an eaves carrier tray if one is fitted, and not stopped short behind the fascia board.
A surprising number of older roofs stop the underlay at the wall plate. Water drains beautifully down the slope and discharges into the top of the wall. Add a roof window and the flow is concentrated into two bays instead of six, which is how a fifty-year-old defect becomes visible the month after a window was fitted. The window did not cause it, but the window gets the blame.
The roofs around here that fail this test
Reinforced bitumen felt has a working life, and a lot of it around Poole has reached the end of it. The post-war and 1960s to 1980s stock at Creekmoor, Canford Heath, Turlin Moor and much of Corfe Mullen was felted with material that is now stiff, dark and brittle. Lift a tile on one of those roofs and the felt often cracks rather than flexes. That matters when a window goes in, because the membrane has to be cut, dressed and taped, and a material that shatters at the fold cannot be dressed to anything. On those roofs we form a new local area of breathable membrane around the opening, lapped generously into the sound felt above and below, and we say so on the quote rather than discovering it on the day.

Condensation wearing a leak’s clothing
Not every damp patch around a roof window is rainwater. Warm, moist air from the room escaping through a gap at the reveal will condense on the cold underside of the underlay and on cold metalwork, run down, and drip. It produces a stain that appears in cold weather rather than wet weather, which is the diagnostic.
The cure is at the inside face: a continuous vapour control layer, sealed to the frame, with no gaps at the corners of the reveal, and insulation packed properly round the perimeter so there is no cold strip for moisture to find. Sealing the outside harder makes it worse, because the moisture is already on the inside. A roof window that drips in January and stays dry in an October downpour is telling you which problem you have.
Wind-driven rain, and why the spit is different
Everything above is more demanding on an exposed roof, because on an exposed roof the rain does not fall, it arrives sideways at speed. Water driven up a lap under pressure defeats details that are perfectly adequate in sheltered conditions.
| Exposure | Where in the service area | What changes at the underlay |
|---|---|---|
| Severe, no fetch break | Sandbanks, the harbour mouth, Studland, Mudeford | Increased laps, taped horizontal and vertical laps at the opening, collar laps sealed rather than lapped dry |
| Open coast | Portland, Barton on Sea, Milford on Sea, Highcliffe | Taped laps around the opening, extra mechanical fixing of the membrane at the perimeter |
| Sheltered marine | Hamworthy, Upton, Lower Parkstone, Wareham | Standard laps, taping at the collar. The land breaks the worst of the wind |
| Inland | Broadstone, Creekmoor, Canford Heath, Ferndown, Wimborne | Standard detail, standard laps. Upgrades here buy nothing and we will say so |
What we check, and what we will not skip
At survey we get into the loft and look at the membrane rather than asking you about it: what it is, what condition it is in, whether it drapes, whether it reaches the gutter, and whether there is anything there at all. That determines the collar, the taping, the laps and whether a local re-membrane is part of the job. All of it goes on the quote in words you can check afterwards.
Two commitments, and no claims we cannot stand behind
A fixed written price after survey, naming the underlay condition and the exposure zone we have specified to. If something genuinely unforeseeable appears once the covering is off, usually rotten battens or a rafter end gone at the wall plate, we stop, show you, and price it separately rather than quietly absorbing or quietly adding it.
A ten-year workmanship guarantee on our installation. It is not insurance backed, and we say so plainly. The window, its sealed unit and the flashing carry their own manufacturer warranties.
If a rooflight or roof window on your roof is staining a reveal and the flashing looks perfect, the layer below it is the first place to look. Ring 01202 923272. We fit and diagnose skylights across Poole, Dorset and into the New Forest, and this is the fault we are called to most.
Related reading
1930s semis in Poole: rafter spacing and the window sizes it allows
Half of suburban Poole was built to one drawing Between the wars the town spread outwards fast, and it spread…
Batten gauge, tile course and lining a window up with the roof
You can see a badly set out window from the pavement Stand on any residential street in Poole and look…
Can a roof window be fitted above a staircase?
Yes, and a stairwell is often the best place in the house for one A roof window over a staircase…
Can a roof window be fitted from inside the loft?
Part of it, yes. All of it, no. A roof window cannot be fitted entirely from inside the loft, and…
Can a roof window be fitted over a bath or shower?
Yes, and a bathroom is one of the best rooms in a house for daylight from above. Three things change…
Can a roof window be fitted to a slate roof?
Yes, with a flashing kit made for slate Slate is one of the easiest coverings to put a roof window…