Setting a roof window between rafters without cutting the structure

How to read your rafter spacing in the loft and choose a roof window width that fits the roof as built, with no trimming and no structural work.

A roof window set between rafters in a pitched coveringThe window sits in the plane of the covering between existing rafters. A flashing kit matched to the covering carries water around the frame, and the underlay is dressed to a collar so anything passing the tiles is returned to the outside.roof windowrafterrafterflashing kitcovering

The loft decides the width, not the brochure

A roof window’s width is settled by whoever framed the roof, usually decades before anyone in the house started thinking about daylight. The width you like in a brochure certainly exists. Whether it goes into your roof without a saw touching a rafter is a different question entirely, and the answer is already sitting above your ceiling.

This guide is about the windows that fit the roof as it stands: no structural design, no trimmers, no conversation with Building Control about where the load goes. The frame lands in a gap that already exists and the roof carries exactly what it carried the day before. Everything that follows is about finding that gap and reading it honestly.

Widening past it is structural carpentry with its own rules and its own guide. Start here anyway, because the decision to cut should be made knowing what was on offer for free.

What is really between two rafters

Rafter centres are measured from the middle of one rafter to the middle of the next. The clear gap, which is the number that matters, is that figure minus one rafter thickness. Common rafters in post-war roofs are 47mm or 50mm sawn. Older Victorian and Edwardian roofs around Parkstone, Westbourne and the Old Town often carry heavier timber, rough sawn, and not laid out with any great consistency down the slope.

Roof framing Centres Clear gap What that allows
Cut roof, 600mm centres 600mm nominal Around 550mm The narrowest standard widths drop straight in with nothing cut
Cut roof, 450mm centres 450mm nominal Around 400mm Nothing in a standard range fits; the choice is trimming or a sun tunnel
Cut roof, 400mm centres 400mm nominal Around 350mm No standard window fits between; at least one rafter comes out
Trussed rafters, 600mm centres 600mm nominal Around 555mm The narrowest width fits. Nothing wider, ever, without a truss designer
Older cut roof, irregular Wanders, often 380mm to 620mm Measure the actual bay Sometimes one generous bay in an otherwise tight roof. Find it before you choose

The last row is the one people miss. A hand-cut roof was set out by eye, so bays are rarely identical, and the variation occasionally gifts you one bay that takes a window the rest of the roof would refuse.

Measuring your own roof before anybody quotes

You can do this yourself in twenty minutes, and it will make every conversation that follows shorter. Take a torch, a tape and a phone for photographs. Stand on the joists or on boarding, never on the plasterboard between them.

  1. Pick the bay you actually want. Daylight is decided by where the window lands over the room, not by where the loft is easiest to stand up in.
  2. Measure centre to centre across at least four rafters. Take the smallest spacing you find, not the average. The window fits the tightest bay it touches.
  3. Measure the clear gap at the height the window will sit. Not at the eaves, where rafters are birdsmouthed over the wall plate and the gap can read wider than it is up the slope.
  4. Measure the rafter depth. 100mm, 150mm, 175mm and 200mm are all common. It matters later for insulation at the perimeter and for whether a recessed installation is possible.
  5. Look along the bay from eaves to ridge. Note anything crossing it: purlin, binder, strut, collar, cable run, soil vent pipe, tank platform.
  6. Photograph the rafter ends and the junction plates. Metal nail plates at every joint mean a trussed roof, and that changes the answer completely.

Six numbers and a handful of photographs is enough for us to tell you on the phone whether the window you want fits between, needs a rafter out, or is not happening on that roof.

The widths that drop in, and the ones that do not

Standard roof window widths cluster around 550mm, 660mm, 780mm, 940mm and 1140mm, with variations by manufacturer. Set against a 550mm clear gap the arithmetic is unforgiving. One width fits; everything above it needs a rafter removed and the load taken round the opening.

Shaving a rafter is not a small cut

The usual suggestion, once the tape has disappointed somebody, is to take a slice off the side of each rafter and squeeze the next size up in. It sounds minor. It is not. A rafter’s resistance to bending is proportional to its breadth and to the square of its depth, so planing 15mm off each side of a 47mm rafter removes roughly a third of its bending strength at exactly the point where you have also cut a hole in the roof. There is no honest way to gain 90mm of clear width by shaving. If the frame does not fit, it does not fit, and the answer is a trimmed opening designed as such.

This is also where the words start blurring. Somebody searching for a narrow skylight and somebody asking for a slim rooflight are usually after the same object. What they want is a unit that fits between what the roof already has, and on a 600mm-centre roof there is precisely one family of widths that does.

Setting a roof window between rafters without cutting the structure
Set in the plane of the covering, with the flashing matched to the slate.

Height is free, width is not

Here is the release valve, and it is the single most useful thing on this page. A roof window runs up the slope, parallel with the rafters. Its length is therefore unconstrained by rafter spacing. You cannot have 940mm of width on a 550mm gap, but you can very often have 1400mm or 1600mm of length on the same gap, and the extra glass is real daylight, not a consolation prize.

Lengths in the standard ranges run roughly 780mm, 980mm, 1180mm, 1400mm and 1600mm, and going longer raises the head, which throws light deeper across the floor than a wide low window does. The limits are the courses kept above the window before the ridge, the eaves detail at the bottom, and the internal head height once the reveal is formed.

The post-war estates around Poole are where this matters most. Creekmoor, Canford Heath, parts of Turlin Moor and much of Corfe Mullen were built with trussed rafter roofs at 600mm centres. On those roofs the tall narrow window is not a compromise; it is the only shape available, and it is a good shape. A 550 by 1400 unit in a Canford Heath loft gives more usable daylight than most people expect from something that looks slim from the pavement.

Two narrow windows instead of one wide one

If one slim unit is not enough, the next move is a pair: window, rafter, window. Manufacturers make combination flashing kits for exactly this, with a defined gap between the frames that matches a standard rafter and its fixing tolerance. Nothing structural is touched, and two apertures spread light across more floor than a single unit of the same total area.

Consideration One wide window, rafter cut Two narrow windows, nothing cut
Structure Trimmers, hangers, a design if the roof is trussed None. The roof is left as built
Daylight across the floor Concentrated, one bright patch Spread wider, softer, fewer hard shadows
The view out Uninterrupted Split by a rafter and two frames
Weathering One flashing perimeter A combi kit with a lined gutter between the units
Programme Longer, structural work first Longer on the roof, shorter overall, no design wait
On a trussed roof Needs an engineered solution or is refused Routine

The honest drawback is the bar of shadow the rafter throws between them, most obvious around midday in summer. It reads as two windows rather than one opening, which is taste rather than performance.

Where the frame actually fixes

The frame is carried on brackets or angle fixings screwed into the sides of the rafters either side, at the heights and centres the manufacturer sets out. Not into the battens, not into the sarking board, and not into a timber that is itself only skew-nailed to something else. Every bracket wants sound, dry, full-thickness timber behind it, which is worth checking at survey rather than at eight in the morning with the tiles already off. Rafter ends at the wall plate are the usual disappointment on older properties near the water, where a blocked gutter has left the last 200mm of timber soft.

Fixing grade follows exposure rather than habit. On the spit, where salt-laden air arrives off open water with nothing to break it, that means A4 stainless. Four miles inland at Broadstone or Canford Heath it does not, and we will say so rather than sell an upgrade the address does not need.

Setting a roof window between rafters without cutting the structure
A profiled tile needs a deeper flashing than a slate does.

What else crosses the bay

A clear gap between rafters is not the same as a clear route to the roof surface. Plenty of otherwise perfect bays have something running through them.

Obstruction Why it is there Usual resolution
Purlin Carries the rafters mid-span on a cut roof Window sits above or below it, or the purlin is boxed into the reveal
Strut or collar Props the purlin, or ties opposing rafters Move the window sideways one bay. Never cut one on the day
Cold water tank Gravity-fed plumbing in older houses Relocate, or use the opposite slope. A plumber’s job, not ours
Soil vent pipe Terminates through the covering Keep a clear course between the two; both need their own flashing
Chimney stack Original to most pre-war Poole housing Leave room for both flashings to work independently, not to share a course

A truss is not a rafter, and the difference decides everything

From the mid-1960s onwards most new British roofs were framed with trussed rafters: thin timbers in a designed triangulated frame, joined with pressed steel nail plates. Every member is doing a calculated job, the diagonal webs that look like they are in the way included. Cut one and the design no longer applies to the roof you are standing in.

The rule, and the only exception

Nothing on a trussed rafter roof gets cut on site. Not a chord, not a web, not a nail plate. A window fits between two trusses or it does not go in. The exception is a designed one: a truss manufacturer or structural engineer can specify a modified or infilled truss arrangement with the load taken on new members. That is a paid design, ordered ahead, not a decision made with a reciprocating saw.

If your loft is a forest of thin diagonals and metal plates, the fit-between window is not a lesser option. It is the option, and the long narrow shape is how you get daylight out of it.

What the survey settles, and what guessing costs

A survey in your loft settles six things: the framing type, the true clear gap at the intended height, the rafter depth, what crosses the bay, the condition of the timber the brackets bear on, and the exposure zone. Those six decide the window, the fixing grade and the price.

Guessing costs predictably. A unit ordered to a brochure width the roof will not take is a restocking problem at best. A frame forced into a bay 20mm short comes back as a sash that will not close evenly: a draught in the first proper south-westerly, a stain on the reveal the winter after, and both reported as a flashing failure.

What we put in writing

A ten-year workmanship guarantee on our installation. It covers our work and it is not insurance backed; we say that plainly because the difference is real. The window, the sealed unit and the flashing carry their own manufacturer warranties, handed over on the day.

A fixed written price after survey, with the exposure zone and the reason for the specification named on it. Send us the six measurements above, or ring 01202 923272, and we will tell you whether the width fits before anyone sells you anything. We fit roof windows, rooflights and skylights across Poole and about thirty miles around it.

Get a fixed quote

Get a fixed quote

Tell us which way your roof faces.

We will come back with a specification, not a catalogue page. If your extension faces south we will tell you the G-value we would fit and why.

  • No pressure, no doorstep sales call
  • We handle the Building Control notification
  • 10-year workmanship guarantee on every installation
  • Installations and replacements across Poole and south Dorset

Prefer to talk it through? 01202 923272