Do VELUX windows come with flashing included?

The short answer

No. The window comes in one box and the flashing comes in another, with its own code, chosen by what your roof is covered in. Ordering one without the other is the commonest mistake in a self-managed job.

A roof window set between rafters in a pitched coveringThe window sits in the plane of the covering between existing rafters. A flashing kit matched to the covering carries water around the frame, and the underlay is dressed to a collar so anything passing the tiles is returned to the outside.roof windowrafterrafterflashing kitcovering

It catches people out because the two are sold side by side and the flashing looks like packaging. It is not packaging. It is the component that keeps the water out, and on the roofs around Poole it is frequently the part of the specification that takes the longest to get right.

What is in the box, and what is not

Item Supplied with the window? What happens if it is missing
Frame, sash and glazing Yes Not applicable
Fixing brackets and handle Yes Not applicable
Flashing kit No, ordered separately by covering type The junction with the roof cannot be formed correctly and the installation leaks
Underfelt collar No, and it is often bundled with the insulation collar Water getting past the tiles has no route back to the underlay, and arrives in the room
Insulation collar No A cold bridge around all four sides of the opening, and condensation with it
Vapour control collar No Moist room air reaches the cold perimeter inside the roof build-up, where nobody sees the consequence for years
Internal lining kit No, optional Nothing structural; the reveal is formed in plasterboard instead

Read that list against a bargain price found online and the bargain usually disappears. There is nothing dishonest about how they are sold, but the headline figure is for a window, not for an installation.

Why the flashing cannot be generic

A flashing kit is pressed and folded to sit against a particular kind of covering. A kit made for deep clay pantiles has to press into a wave; a kit made for slate has to lie flat against a thin, even surface. Neither will do the other one’s job, and the difference is a measurement rather than an opinion: the profile depth of the covering, taken with a rule at the position of the proposed opening.

Across our service area that means at least three distinct answers. Deep interlocking concrete tiles on the post-war estates, natural slate and plain clay tile on the Victorian streets, and Purbeck stone slates on the Isle of Purbeck, which fall outside the boxed kits altogether and take a formed detail made on site.

Ordering it correctly

  1. Identify the covering and measure its profile depth at the opening, not at the eaves.
  2. Decide whether the window is being fitted standard or recessed, because that selects a different flashing family.
  3. Match the flashing size code to the window size code. They correspond and a mismatch cannot be adapted on site.
  4. If more than one window is going in side by side, order a combination kit, which sets the gap between the frames.
  5. Add the collars as separate line items. They are separate items.

Reusing an old flashing on a replacement

Almost always a false economy

The theory is that if the window size is unchanged, the old kit should still fit. Occasionally it does.

The practice is that flashing kits are matched to the frame generation as well as the size, and a kit that has been weathering on a Dorset roof for twenty years has work-hardened creases, fixing holes in the wrong places for the new frame, and a surface finish that has done its service. Reusing it saves a modest sum and puts the entire installation on the oldest component in it.

Salt, and what it does to the kit

Flashing sections weather like anything else exposed to the sky. Inland, across Wimborne, Ferndown and Verwood, they do it slowly and predictably. Out on the spit at Sandbanks, or at Mudeford and Highcliffe where the salt load is genuine, surface deterioration runs faster and the fixings deserve as much attention as the sheet. We specify stainless fixings there as standard, and an inspection interval agreed at handover rather than a claim that anything is immune.

If a quote does not mention it

Ask. A quote for supplying and fitting a skylight that does not name a flashing family is either incomplete or assumes something about your roof that nobody has measured. Ours names the covering, the flashing family and the collars, because those three decide whether the rooflight is watertight in ten years’ time.

Call 01202 923272 and we will tell you which family your roof needs before you buy anything.

Get a fixed quote

Get a fixed quote

Tell us which way your roof faces.

We will come back with a specification, not a catalogue page. If your extension faces south we will tell you the G-value we would fit and why.

  • No pressure, no doorstep sales call
  • We handle the Building Control notification
  • 10-year workmanship guarantee on every installation
  • Installations and replacements across Poole and south Dorset

Prefer to talk it through? 01202 923272