Does a sun tunnel need an electrician?
Not for the daylight. A sun tunnel has no electrical parts at all — it is a dome, a tube and a diffuser, and nothing in it is wired. You need an electrician only if you add a light kit, and if that kit is going into a bathroom the work is notifiable and must be certified by the person who carries it out.
The daylight half is entirely passive
It is worth saying plainly because the question comes up so often. Installing a tunnel is roofing and ceiling work: a flashed opening in the covering, a tube through the loft, a round opening in the plasterboard. No circuit is touched, nothing is switched, and nothing needs testing afterwards.
What the installer does need to do is find the cables that are already up there and route around them, which is a competence question rather than an electrical qualification.
When an electrician becomes necessary
| What you are having done | Electrician needed? | Notes |
|---|---|---|
| Tunnel, daylight only | No | No electrical work of any kind takes place |
| Light kit in a hall or landing | Yes | New wiring and a connection to an existing circuit |
| Light kit in a bathroom or shower room | Yes, and notifiable | Special location rules apply to the whole room |
| Reusing an existing fitting position | Yes | Altering the point is still electrical work |
| A new circuit at the consumer unit | Yes, and notifiable | Rarely required for one light, but it happens |
What notifiable actually means
Part P of the Building Regulations, in England
Certain domestic electrical work has to be notified to building control. In England that includes new circuits and, relevantly here, work in a room containing a bath or a shower, which counts as a special location.
There are two routes. Either the work is carried out by an electrician registered with a competent person scheme, who self-certifies it and notifies on your behalf — or an application is made to the building control body for the area before the work starts. Which authority that is depends on where you live: BCP Council across Poole, Bournemouth and Christchurch, Dorset Council for Wareham, Wimborne, Swanage and the Purbeck area, and New Forest District Council for Lymington, Ringwood and the Hampshire side.
Either way you should end up holding a certificate. If a light kit is installed in a bathroom and nobody gives you paperwork, that is a gap you will notice when you come to sell.
Bathroom zones, in one paragraph
A room with a bath or shower is divided into zones, and a fitting has to suit the zone it sits in — principally in terms of ingress protection and how the circuit is supplied and protected. A ceiling-mounted light above a bath is entirely normal; it simply has to be the right fitting, installed by someone who knows the rules. The specification side of that is on the light kit page.
What we do and what we do not claim
We install the tunnel. Where a light kit is wanted, the electrical work is carried out and certified by a qualified electrician, and the certificate comes from them rather than from us.
You are equally welcome to use your own electrician. If you do, the useful thing is to have them there, or at least to have the cable route agreed, while the ceiling is open.
Sequence, if you want it done once
- Agree the tunnel position and the switch position at survey, together, before anything is ordered.
- Run the cable while the loft is open and the ceiling is out. This is the step that is cheap now and expensive later.
- Fit the kit at the diffuser end before the collar is finally sealed, so the seal is made once.
- Terminate, test and certify. Paperwork issued at the time, not posted on later.
- Check it after dark. Colour and output are subjective and this is the only way to know.
Plan for the cable even if you are undecided
The commonest small regret in this job is deciding against a light kit, then wanting one two years on and finding the loft has since been boarded and topped up with insulation. Having a cable run and left capped while everything is open costs very little at the time and removes the worst part of the work later.
The thing no electrician can fix
A light kit makes the tunnel useful after dark. It does not improve the daylight, and if the daylight is disappointing because the run is long or the dome sits under a pine canopy, wiring is not the remedy.
And if the room has a roof plane of its own, the honest answer is the one we give everywhere on this site: a sun tunnel is not a substitute for a rooflight where a rooflight would fit, and a skylight in that slope would deliver more daylight than any electric kit is standing in for. Fixed written price after survey, ten-year workmanship guarantee which is ours and is not insurance backed. Ring 01202 923272.
Related reading
1930s Poole semis with internal bathrooms and no wall to reach
The interwar semi built across Parkstone, Winton, Penn Hill and Oakdale has a recognisable problem: a bathroom in the middle…
Adding a light kit so the tunnel works after dark
A sun tunnel goes dark when the sky does. In a bathroom or a hall that had no daylight at…
Are sun tunnels warm or do they lose heat?
A sun tunnel is a hole through your insulated ceiling, so yes, it loses some heat — and a properly…
Broadstone bungalows where the loft void is shallow and wide
Broadstone, Creekmoor and the bungalow runs out towards Corfe Mullen were built low and built wide. Every room sits on…
Can a sun tunnel be fitted in a bathroom?
Yes. A windowless internal bathroom or en-suite is the single most common place a sun tunnel earns its keep, and…
Can a sun tunnel be fitted into a Purbeck stone slate roof?
Yes, but not with a kit. Purbeck stone slates are thick, heavy and laid in diminishing courses, and there is…