The short answer

A properly installed roof lantern does not leak. When one does, the water has almost always arrived through the kerb, the flashing or the roof covering around the unit rather than through the glazing itself — which is why a leak at a lantern is usually a roofing fault wearing a glazing costume.

Section through a roof lantern on a kerbA roof lantern is a pitched glazed structure standing on a kerb above a flat roof. The pitch sheds water and debris and distributes light; it is not a flat rooflight with a hat on.ridge barglazing barkerbflat roof deckpitch sheds water

Why the glass is almost never the first thing to fail

A lantern is not sealed like a jam jar. Each pane sits on a gasket along the rafter bars and is held down by a pressure cap screwed through into the bar beneath it. A little water is expected to get past that cap in driving rain, and the bar carries a drainage channel underneath precisely to catch it and run it down to the eaves detail where it rejoins the outside of the building.

That is the design: it manages water rather than pretending to exclude it perfectly, and a well-made flat rooflight works the same way. So when a wet patch appears on the plasterboard, the glazing is the last place we look. The likely places all sit below the glass line — in the part of the job a roofer built, not the part a factory made.

It matters because the fixes are different. A failed seal means a new unit. A failed kerb detail means opening the roof covering, and no amount of sealant round the outside of a skylight holds that for a winter.

The five places water actually gets in

Where What has gone wrong What you see inside
Kerb to roof junction The covering was not dressed up the upstand properly, or terminated without a mechanical fix and has crept back down Staining that starts at one corner of the reveal and spreads along one side
Upstand termination The covering stops short of the frame line, leaving the top edge exposed to whatever runs down the glass Wet only in sustained driving rain, dry in ordinary showers
Frame bedded on the kerb The lantern was set on an uneven kerb and the bedding bridges a gap instead of filling it A drip at one point, repeatable, always the same spot
Caps, gaskets and end closures A cap screw overtightened onto the gasket, or a ridge end cap never fitted Water tracking down the inside face of a bar, often mistaken for condensation
The roof beyond the lantern A split, a ponding area or a failed lap elsewhere on the deck; the opening is simply the water’s exit Wet after heavy rain, nowhere near the worst-affected part of the roof

Four of those five are roofing work, which is the short answer to why lanterns get blamed for leaks they did not cause.

Condensation is not a leak, and it is the commonest false alarm

More calls about water under a lantern turn out to be condensation than a leak. A kitchen-diner with a hob, a kettle and a family in it makes a great deal of moisture, and the coldest surface in the room is the inside face of the glazing. It condenses there, runs down the panes, gathers along the bottom bar and drips.

Telling them apart without going on the roof

Condensation appears on cold mornings regardless of rain, is worst when the room has been shut up overnight, forms evenly across several panes and clears as the room warms. A leak tracks rainfall, appears in the same place every time, and does not care what the room is doing.

Condensation is cured by ventilation, a warm-edge spacer and an insulated kerb — not by a new lantern. A leak is not cured by sealant from the outside.

Wind-driven rain is the Poole variable

Poole is not one exposure, and rain does not arrive the same way across it. At Sandbanks and the harbour mouth the prevailing south-westerly has no fetch break, so rain arrives close to horizontal and is pushed up a kerb face rather than falling onto it. Behind the Quay and the Old Town the land takes most of that out. In Broadstone and Creekmoor the driving-rain load is ordinary inland weather.

The detail that survives a Creekmoor winter untouched can be the detail that lets water past on the spit. That is a specification question rather than a workmanship one, settled before anything is ordered.

What actually keeps a lantern dry

Four things. A kerb built square, level and high enough for the covering to be dressed up it. Waterproofing taken up that kerb and mechanically terminated, so the opening is watertight before the lantern arrives. A frame bedded on a flat surface, not bridged over a wavy one. And fixings that suit the exposure, because a corroded fixing works loose and a loose frame opens a gap.

The rule

A roof lantern is made watertight at the kerb, not at the glass. A quote that treats the kerb as a preliminary is quoting for the wrong thing. How it is built: can a lantern sit on a flat roof without a kerb.

Tracing a leak on an existing lantern

  1. Rule out condensation first. A week of noting when the water appears against when it rained settles it without anyone going up a ladder.
  2. Check the roof away from the lantern. Ponding, splits and failed laps elsewhere on the deck send water to the nearest opening.
  3. Look at the termination. Where the covering stops against the frame is visible from a tower and tells you most of what you need.
  4. Hose test in stages. Bottom of the kerb, then the upstand, then the glass line, ten minutes each with someone inside watching. Wetting it all at once proves nothing.
  5. Fix the layer that failed. Which usually means roof covering and kerb, occasionally a gasket or cap, and only rarely a sealed unit.

If the glazing itself has failed — misting between the panes rather than water on the inside face — that is a different fault entirely, covered under replacing a failed or misted rooflight.

If yours is leaking now

We install and replace rooflights and lanterns across Poole and about thirty miles around it. We are not a general roofing firm, so if the fault is the deck rather than the glazing we will say so rather than sell you a lantern to cover it.

What we put in writing

A ten-year workmanship guarantee on our installation work. It is a workmanship guarantee and it is not insurance backed — we would rather you heard that from us. And a fixed written price after survey, with any roof repair itemised separately so you can see what is glazing and what is not.

To get a leak looked at, ring 01202 923272 or ask for a survey.

Get a fixed quote

Get a fixed quote

Tell us which way your roof faces.

We will come back with a specification, not a catalogue page. If your extension faces south we will tell you the G-value we would fit and why.

  • No pressure, no doorstep sales call
  • We handle the Building Control notification
  • 10-year workmanship guarantee on every installation
  • Installations and replacements across Poole and south Dorset