What happens to an electric rooflight in a power cut?
It stops exactly where it is and stays there — open if it was open — because the motor, the controller and the rain sensor all run from the same supply, so losing power takes all three at once.
What “stops where it is” means at nine on a wet evening
If the skylight was shut, nothing happens and you will not notice until you try to open it. If it was open a few inches for a hot kitchen, it is open a few inches for as long as the outage lasts, with no automatic anything to intervene.
That is a routine inconvenience in most of the service area and a genuine problem in some of it, because the weather that interrupts a supply in Dorset is the weather that then drives rain through the opening. Around Poole the two arrive together on the same south-westerly.
The rain sensor goes down with everything else
This is the part that catches people, because a rain sensor feels like a safety device. It is not independent. The pad, the controller reading it and the drive it commands all sit downstream of the same transformer. With no supply the pad can be soaking and nothing hears it.
Worth being clear about
A rain sensor protects you from forgetting. It does not protect you from a power cut. Those are different problems, and only the first one has a sensor as its answer — the second needs a backup module, a manual override, or a rooflight positioned so that an open sash does not matter.
What happens when the supply comes back
Almost always: nothing, until someone presses something. Controllers hold their commissioned travel limits in memory that survives an outage, so the unit does not need recommissioning and does not forget how far it opens. What varies is whether it does anything on its own at the moment power returns.
| On restoration | What the unit does | What it means for you |
|---|---|---|
| Most domestic controllers | Wake up idle, sash where it was left | You close it at the switch when you notice |
| Controllers with a rain input active | Read the pad immediately and close if it is wet | A pleasant surprise, but not something to count on |
| Units with a backup module fitted | Never stopped; may already have closed itself at the outage | The module recharges, and wants testing afterwards |
| Timer or scene-based control | May resume at the next scheduled event | Check the clock has not reset, or the schedule drifts an hour |
Travel limits surviving is the useful half of this. A power cut does not damage a correctly installed skylight, and it does not leave you needing an engineer to reset it.
If it is open and the rain is coming
Do the easy checks before assuming the street has lost power. If the rest of the house is lit, the problem may be at the fused spur — a blown fuse or a tripped device — rather than a supply failure at all, and that is a two-minute fix rather than an evening.
If the supply really has gone, use the manual override if the unit has one, from the floor, with a pole or crank. Do not push a sash against an engaged motor and do not go onto a wet roof at night. What each override type does, and how to test yours before you need it, is set out in the guide to what a vent does when the mains fails.
The two exceptions
A solar-powered skylight is unaffected, because it never used the house supply at all. It has its own version of the problem in a flat battery, which is a real consideration under the protected pine canopy at Branksome Park and Canford Cliffs, and that is dealt with in the guide linked above.
An escape rooflight is the other. A unit serving as a means of escape from a loft room has to open by hand, with no power anywhere in the chain, which is why we specify a manual top-hung unit for that duty rather than a motorised one with a battery behind it. A battery has a date on it. An escape route does not get to depend on one.
What we fit, and where
On the spit it is standard, inland it is optional. At Sandbanks, Studland and Mudeford the wind that takes the supply out is the wind driving rain through the opening, and an open sash is also acting as a sail on its own hinges — so a backup module and a restricted opening angle go on the quotation as standard. At Broadstone or Canford Heath, over a hall, with a reachable override, we will tell you plainly that a module is an option rather than a need.
Our commissioning includes testing the override with you watching, from floor level, and writing the date on any backup module so the annual test has something to measure against. To talk through what your rooflight should do on the night the lights go out, ring 01202 923272.
Related reading
Are electric rooflights noisy when they open?
No. A correctly installed unit makes a low hum for the twenty or thirty seconds it is moving and is…
Cable routing through a warm deck without breaching the vapour layer
The electrical side of getting power to an actuator is a settled matter, and it is set out on wiring…
Can a fixed rooflight be upgraded to an opening one?
Almost always this turns out to be a replacement rather than an upgrade, because a fixed rooflight has no hinge,…
Can a rooflight be set to close automatically at night?
Yes. A timed close is the most useful automation an opening rooflight can have, and unlike most of them it…
Can a smoke vent rooflight be used for everyday ventilation?
Technically, often yes — many certified automatic opening vents include a comfort ventilation mode, and it works. Practically, it is…
Can an electric rooflight be controlled from a phone?
Yes — either through a gateway that bridges the rooflight controller onto your home network, or through a manufacturer’s own…