Are electric rooflights noisy when they open?

The short answer

No. A correctly installed unit makes a low hum for the twenty or thirty seconds it is moving and is silent the rest of the time, and anything louder than that is a symptom rather than a characteristic.

An opening rooflight and the parts that move itA chain or spindle actuator drives the sash open against its hinges. The cable is routed to the kerb before the ceiling closes, because reaching it afterwards means opening the ceiling. An open sash on an exposed roof is a sail, which is what wind sensors and restrictors answer.sashactuatorhingecable routed before the ceiling closeswind load on an open sash

What you actually hear

A small direct-current motor turning under light load is not a loud thing. Most of what reaches the room is mechanical rather than electrical: the chain or spindle moving, the sash releasing from its gasket at the start of travel, and a small clunk as the drive reaches its limit and stops.

The two drive families sound slightly different. A chain actuator has a faint ratcheting quality as links leave the housing and lock. A spindle drive is smoother and lower, more of a whirr. Neither is intrusive, and in an open-plan kitchen with anything else going on you will generally lose both.

Volume, without inventing a number

We will not quote a decibel figure, because the figure that matters is the one in your room and it depends on ceiling height, hard surfaces and what the frame is fixed to. The useful comparison is that a domestic skylight actuator is quieter than an extract fan and much quieter than a kitchen extractor on its middle setting — audible if the room is silent, unnoticed if it is not.

It is also brief. Twenty to thirty seconds, once or twice a day, which is a different proposition from a fan running for an hour.

The sounds that mean something

Sound Usual cause What it needs
Grinding or grating Salt or grit in the hinge knuckles or chain joints Fresh-water rinse and a dry PTFE lubricant, before the drive is blamed
A squeal near the end of travel A drive working at its limit against a stiff gasket Check the limits and the sizing — the motor may be under-specified
Clicking or stuttering Voltage sagging on a long low-voltage run, or a loose terminal The supply checked before the actuator is replaced
A thump as it stops Limits set slightly beyond the mechanical stop Recommissioning, a five-minute job
Rattling in the wind when shut Gasket compression lost, or a sash no longer sitting square Adjustment now, before it becomes a leak

The first row is the one we hear about most around the harbour and on the spit. A rooflight that has become noticeably noisier over two or three years has almost always got stiff rather than gone faulty, and the cure is maintenance rather than a new motor.

The frame is the loudspeaker

A motor bolted to an aluminium frame, which is bolted to a timber kerb, which is built into a ceiling, has three chances to turn a small vibration into an audible one. This is structure-borne sound, and it is why the same unit can be inaudible in one house and clearly heard in another.

What controls it is workmanship rather than product: the drive mounted on the maker’s fixing centres and not packed out to fit, the kerb built tight and square, the frame properly bedded, and nothing left over-tightened against a distorted section. Most noise complaints we are asked to look at turn out to be an installation detail rather than a component.

Rain on the glass is a different question

People sometimes ask about noise meaning weather rather than motors. A sealed glass rooflight is a solid, laminated, heavy thing and handles rain very differently from an old polycarbonate dome — the drumming that makes people ask this question belongs mostly to domes and thin plastic units on 1980s and 1990s extensions.

That said, a large glass skylight directly over a bedroom in heavy rain is audible. If a quiet bedroom is the priority, say so at survey: the make-up of the glass and the position of the unit relative to the bed both make a difference, and both are decided before ordering.

Bedrooms, night use and timers

A small thing worth asking for

If the unit is over a bedroom and might be set to close on a timer or a humidity reading, ask what it will do at three in the morning. A rooflight closing itself is not loud, but it is unexpected, and unexpected is what wakes people. Scheduling the movement for a time somebody is awake usually solves it, and that is a commissioning setting rather than a different product.

What we do about it at commissioning

We run the unit ten full cycles from every control point and listen, because a limit that drifts or a fixing that has not quite seated shows up on the third or fourth run rather than the first. The drive gets checked on its proper centres, the hinges get lubricated dry rather than oiled, and the travel limits get set to stop at the mechanical stop rather than into it.

If your existing electric rooflight has become noisy, it is worth a look before it is worth a new actuator — in this part of Dorset the odds are heavily on salt in a hinge. Ring 01202 923272.

Get a fixed quote

Get a fixed quote

Tell us which way your roof faces.

We will come back with a specification, not a catalogue page. If your extension faces south we will tell you the G-value we would fit and why.

  • No pressure, no doorstep sales call
  • We handle the Building Control notification
  • 10-year workmanship guarantee on every installation
  • Installations and replacements across Poole and south Dorset

Prefer to talk it through? 01202 923272