Condensation on the inside of the glass is a humidity problem
Internal condensation on a rooflight is the house telling you how much moisture it is carrying and how cold the coldest surface is, and the fix is a moisture budget rather than a new pane of glass.
A week with a hygrometer settles it faster than an argument
Almost every conversation about a wet skylight starts in the wrong place. The owner has decided the unit is at fault, the installer has decided the house is at fault, and neither position can be tested by looking at the glass. A cheap hygrometer left in the room for a week ends the argument, because the pattern it records is the diagnosis.
What you are looking for is not a single reading but a shape. Humidity that climbs sharply in the evening and falls back overnight is a production problem, and the spikes will line up with cooking, bathing or laundry. Humidity that sits high and flat around the clock is a ventilation problem, because the moisture is going in and never coming out. Humidity that only misbehaves on the coldest nights is a surface temperature problem, and that is the one where the rooflight itself is genuinely implicated.
This page is about the underlying physics and the levers that move it. If what you actually want is the symptom-level diagnosis — which pane is wet, what that means, and what to do first — that sits on why condensation forms on the inside of a rooflight and is not repeated here.
Relative humidity is a ratio, and the ratio is the trap
The number on the hygrometer is relative humidity: the moisture in the air expressed as a percentage of the most that air could hold at its current temperature. Because the denominator moves with temperature, the same quantity of water vapour reads as a different percentage in a warm room and a cool one.
That is why turning the heating down to save money often makes condensation worse rather than better. Nothing has been added to the air. The air has simply become less able to hold what was already in it, the relative humidity climbs, and the dew point rises towards the surface temperature of the coldest thing in the room.
Dew point is a surface temperature, not a weather forecast
The useful number is the dew point: the temperature at which the air in the room becomes saturated. Any surface colder than that collects water. Any surface warmer than it stays dry. The whole subject reduces to a comparison between two temperatures — the dew point of the room air and the temperature of the glass.
| Room air | Relative humidity | Dew point, approximately | What that means at the glass |
|---|---|---|---|
| 20°C | 50% | 9°C | A sound insulated unit stays well clear of this on almost any night |
| 20°C | 60% | 12°C | The edge strip around the pane and the corners of the reveal start to be at risk |
| 20°C | 70% | 14°C | Most rooflights will wet at the perimeter on a cold night, whatever the specification |
| 18°C | 65% | 11°C | A cooler room at the same moisture load is closer to trouble, not further from it |
Those are standard psychrometric values, rounded, describing air rather than any product. The point is the spacing: each step up in relative humidity moves the dew point several degrees, which is a long way in glass surface temperatures. You cannot buy your way past a 70% room.
Where the moisture comes from, in order of size
Water vapour in a house is generated, not imported. In winter the outside air is cold and therefore dry in absolute terms, so almost all of the moisture indoors was put there by the people living there. Ranked by how much they contribute in a typical week:
- Drying laundry indoors. Consistently the largest single source, and the one most often not recognised as a source at all. A load of washing hung on a radiator puts every litre it was holding into the room air.
- An unvented tumble dryer. A condensing dryer helps; a vented one ducted properly outside removes the problem entirely; a dryer venting into the utility room is a humidifier.
- Cooking without extract, or with extract that recirculates. A recirculating cooker hood filters grease and returns the steam to the room. It is not ventilation.
- Bathing and showering. Large but short-lived, and easily dealt with by an extract fan that runs on afterwards and a door kept shut while it does.
- The occupants themselves. Breathing and perspiration are continuous and unavoidable, which is why occupancy density matters and why a spare room slept in by guests suddenly streams.
- Unvented flueless heaters and drying building work. A paraffin or bottled-gas heater produces water as it burns. A new screed, plaster or render releases moisture for months.
We will not put litre figures against those, because the honest range for each is wide enough that a number would be decoration rather than measurement.

Stratification: the wettest air in the house is at ceiling level
Warm air holds more moisture and warm air rises, so the air in contact with a rooflight is both the warmest and the most heavily loaded in the room. The plume from a hob or a shower does not disperse evenly — it goes up, spreads across the ceiling plane and pools there. A skylight is the one piece of glazing sitting directly in that layer.
The reveal makes it worse. A rooflight in a warm deck roof sits at the top of a lined shaft, often a couple of hundred millimetres deep and sometimes a great deal more. That shaft is a pocket. Air that enters it is not swept by room air movement, it stays there, and it is the most humid air available.
Two details decide whether the pocket drains or stagnates. A square reveal, with vertical sides meeting the frame at a right angle, traps air in its corners and those corners are also where the insulation is hardest to keep continuous — so the coldest surface and the stillest air coincide. A splayed reveal, cut back so the opening widens into the room, lets room air wash the glass and lets the corners see the room. It is a joinery decision made at first fix that determines whether the owner is wiping the frame every December.
Three levers, and there are only three
Everything you can do falls into one of these
Put less moisture in. Vent the dryer, stop drying laundry on radiators, use the cooker hood and check it discharges outside. Free, and usually the biggest single move.
Take more moisture out. Ventilation, continuously or on demand. In winter this works precisely because cold outside air is dry, so exchanging it lowers the indoor moisture load even though the air outside feels damp.
Make the cold surface warmer. A better unit, a warm edge spacer, a continuously insulated kerb, a splayed reveal. This is the only lever a glazing specification can pull, and it is the most expensive of the three.
A firm that sells you the third without mentioning the first two has sold you the most costly available answer to a question you could have settled with a vented dryer.
Ventilation that actually moves the moisture
Opening a rooflight for ten minutes is not a ventilation strategy in January, and it is a particularly poor one on the exposed side of the harbour where the wind will take the heat out of the room in seconds. The realistic options differ in whether they run when nobody is thinking about them.
| Approach | What it does well | Where it falls down |
|---|---|---|
| Trickle vents and background openings | Continuous, unnoticed, no running cost, and required as reasonable provision on most replacement work | Depends on wind and temperature difference, and is routinely taped over by the occupant |
| Intermittent extract in kitchen and bathroom | Deals with the two big short-lived sources at the point they are produced | Only works if it is switched on, runs on afterwards, and actually ducts outside rather than into a void |
| Continuous low-rate mechanical extract | Runs all the time at a low rate and boosts on demand, so the moisture never accumulates | Needs a sensible duct route and a make-up air path; a sealed room starves it |
| Mechanical ventilation with heat recovery | Exchanges the air without throwing the heat away, which is the objection to every other method | A whole-house installation with commissioning and filters. Realistic in a deep retrofit, rarely worth retrofitting for one wet skylight |
Measuring it instead of guessing
- Log the room for a week. Temperature and relative humidity, in the room with the rooflight, not in the hall.
- Log outside as well. Without the outdoor reading you cannot tell whether ventilation would help or make it worse, and on a mild wet Dorset week it genuinely can be the latter.
- Note what happened each day. Washing dried indoors, long showers, a full house at the weekend. The correlations are usually obvious once written down.
- Take a surface temperature. An infrared thermometer costs very little and tells you the temperature of the centre of the pane, the edge strip and the reveal corner. Those three readings almost always differ by several degrees.
- Compare the coldest surface with the dew point. If the reveal corner is below the dew point and the centre of the glass is above it, you have a thermal bridge, not a glazing failure.

Coastal Dorset air is humid, and that is not the reason
Outside air around Poole Harbour is frequently at or near saturation, and it is still drier than the air in the room. Saturated air at 5°C holds a fraction of the water that 20°C air at 60% holds. Relative humidity outdoors tells you almost nothing about whether ventilating will help; the absolute moisture content is what matters, and in winter it is nearly always lower outside.
Where the local air genuinely does bite is in the shoulder seasons and in low-lying, sheltered spots — Holes Bay, Upton, the Wareham water meadows, the lower ground behind the Quay. On a mild, still, saturated October night the outside air can be carrying as much moisture as the inside air, ventilation stops helping, and the only lever left is surface temperature. That is the weather in which a poorly detailed kerb shows itself.
What we change on the building side
The glass is rarely the weak point; the perimeter is. On a survey we look at the continuity of insulation from the roof deck up the kerb and over its head, because a kerb insulated on three sides and left bare on the fourth is a fin conducting heat straight out. We look at the spacer in the unit, since the edge strip is the coldest part of any sealed unit and a warm edge type raises that strip by a useful margin — set out on warm edge spacers and the cold strip around the glass. We look at the reveal geometry and specify a splay where the depth warrants it. And we keep recessed downlights out of the reveal lining, because each one is a hole through the airtight layer at the highest and wettest point in the room.
What we will and will not tell you
We will name the exposure zone your roof sits in, state the build-up that zone gets, and put the manufacturer’s declared figures for the actual unit on the quotation rather than a range from an article. Where the survey shows the problem is a moisture budget rather than a skylight, we will say so, and we would rather lose the order than sell a replacement that will wet at the edge next winter for the same reason the old one did.
What we will not do is promise a condensation-free rooflight. No installer can, because the dew point is set in your kitchen and not in our workshop. Our installation work carries a ten-year workmanship guarantee — a workmanship guarantee, plainly, and not insurance backed — and the price is fixed in writing after survey. If the glass is wet every morning, ring 01202 923272 and start by telling us what the hygrometer says.
Related reading
Argon and krypton fills matter less than the brochure suggests
The cheapest line on the specification is usually the loudest Argon fill appears on almost every glazing quotation in the…
Do rooflights cause draughts?
A correctly installed one should not. When a skylight is blamed for a draught it is almost always one of…
Do rooflights help with damp in a room?
With one kind of damp, and only if it opens. A skylight does nothing whatever for rising or penetrating damp…
Do rooflights lose more heat than walls?
Per square metre, yes, and it is not close. Any glazing loses heat several times faster than the insulated fabric…
Do rooflights make a room colder in winter?
No, not a modern one. A well-specified rooflight in a well-detailed opening adds heat loss in the same way any…
Do solar control rooflights make a room darker?
Slightly. Every solar control coating takes some daylight with the heat, because it is impossible to remove energy from sunlight…