Are sun tunnels warm or do they lose heat?

The short answer

A sun tunnel is a hole through your insulated ceiling, so yes, it loses some heat — and a properly sleeved, properly sealed one loses very little. It also brings in a small amount of warmth with the daylight. The thing that actually matters is not the heat loss but the air leakage, because that is what causes condensation.

A sun tunnel run from dome to diffuserLight enters at the dome and is reflected down the tube to a ceiling diffuser. Every bend costs reflectance, so a straight short run delivers far more than a long one with turns. Light falls with the square of the diameter.daylightdomeevery bend costs lightceiling diffuser

Three separate things people mean by this question

The first is conducted heat loss: warmth passing through the diffuser, the tube and the dome to the outside. The second is air leakage: warm moist air escaping from the room into the loft around a badly fitted collar. The third is solar gain: heat arriving with the light on a sunny day.

They behave differently, they are fixed by different details, and lumping them together is why the answers people get are confusing.

How each one behaves

Effect Scale in a domestic installation What controls it
Conducted heat loss Small, because the aperture is small The sleeve, and the glazing of dome and diffuser
Air leakage at the ceiling Potentially the largest of the three, and avoidable A properly sealed collar at the ceiling
Solar gain Modest; noticeable in a small room in summer Diameter, orientation and what the dome can see
Cold bridging at the tube Small in heat terms, significant for condensation Continuous sleeving with no gaps or crushing

The second row is the one worth your attention. A gap at the ceiling trim behaves as a small chimney, drawing warm wet air out of the room continuously, which loses heat and delivers moisture into the loft at the same time.

Why the aperture being small matters

Heat loss through any element of a building scales with its area. A tunnel’s opening is a circle a few hundred millimetres across — a fraction of the area of even a modest rooflight, and a tiny fraction of a window.

So while a tunnel is undeniably a weaker point in the ceiling than the insulated plasterboard around it, the total amount involved is limited by how little of the ceiling it occupies. That is the honest framing: a small weak spot, not a hole in your heating.

What a good installation includes

  1. A sleeve over the full cold length. Not most of it. The uninsulated part becomes the coldest surface in the loft and everything finds it.
  2. Sleeve continuous with the loft insulation. Butted and dressed, with no ring of open space where the two meet.
  3. A sealed collar at the ceiling. Continuous all the way round, to the ceiling’s vapour-resisting layer where one exists.
  4. Taped joints along the tube. A tunnel should be a closed run from dome to diffuser. Open collars leak light and air together.
  5. Loft ventilation left working. Insulation pushed back to clear the tunnel must not block the eaves.
  6. The right dome and diffuser for the product. Their glazing arrangement is part of the thermal performance, and it is declared by the manufacturer.

The figures, and who owns them

Thermal performance for a specific tunnel is declared by its manufacturer for the assembled product, measured against a standard. That declaration is what governs, and it is the figure that should appear on a building control submission if one is needed.

We will tell you which product we propose and where its declared figures are published. What we will not do is quote you a number from memory, because a thermal figure without the product, the diameter and the test behind it is not information.

Solar gain, and when it is noticeable

A real effect, at a realistic scale

A tunnel does bring warmth in with the light. In a small internal bathroom or cloakroom on a south or west slope, on a hot afternoon, you may notice it. The room is small, so a modest gain goes further than it would in a large space.

The exception worth naming: this is nothing like the solar gain from a large skylight or a roof lantern, which has many times the glazed area and is a genuine overheating consideration in a kitchen extension. If somebody is warning you about a tunnel overheating a room, they are describing a different product’s problem — and if the room would take a rooflight, that gain is part of what you would be weighing up.

The connection to condensation

Heat and moisture are the same conversation here. A tube that is cold because it was not sleeved properly is also a surface that moisture will collect on. A collar that leaks warm air is also delivering vapour into the tunnel and the loft.

Which is why the fix for both is the same fix, done once, properly, at installation. The full explanation is on the condensation and insulation sleeve page, and it is the single most useful page in this hub if you already have a tunnel that is behaving badly.

What our quotation says

Written down, not assumed

The quotation names the product so you can read its declared thermal figures yourself, states that the full cold length is sleeved and that the ceiling collar is sealed, and names the exposure zone your roof sits in — because a dome on the Sandbanks spit and a dome in sheltered Ferndown do not get the same specification, and marine-grade materials inland are an overcharge we will not make.

It is a fixed written price after survey. Our workmanship carries a ten-year guarantee, which is our own guarantee and is not insurance backed. Ring 01202 923272.

Get a fixed quote

Get a fixed quote

Tell us which way your roof faces.

We will come back with a specification, not a catalogue page. If your extension faces south we will tell you the G-value we would fit and why.

  • No pressure, no doorstep sales call
  • We handle the Building Control notification
  • 10-year workmanship guarantee on every installation
  • Installations and replacements across Poole and south Dorset

Prefer to talk it through? 01202 923272