Why does condensation form on the inside of my rooflight?

The short answer

Because that surface is colder than the dew point of the air in the room. Warm air holds moisture; cool it enough and it cannot, and the surplus lands on whatever cooled it. A rooflight is usually the coldest surface in the room and it sits in the one place the warmest, wettest air in the house collects, so it is where the water appears first.

U-value and g-value pull in opposite directionsU-value measures heat leaving through the unit; g-value measures solar energy coming in. A coating that cuts summer gain also cuts the winter daylight and warmth a room receives, which is why the right answer depends on orientation and on what shades the roof.solar energy ing-valueheat outU-valueglazed unitlowering one usually raises the other

That makes it a humidity and surface-temperature problem, not a leak, and not in most cases a fault in the glass.

Where it sits names the fault

Look at the pattern rather than the quantity. Wipe the glass dry at night and photograph it in the morning.

Where the water is What it means Where the fix lies
A band round the perimeter of every pane The spacer. A conductive bar bridging cold outer glass to warm inner glass, all the way round A warm edge spacer, which can only be specified in a new sealed unit and never retro-fitted
Across the whole pane, evenly Room humidity is high, or the unit is old and uncoated and the whole inner face is running cold Ventilation and moisture sources first, then the unit if it is pre-2000 and has no low-emissivity coating
On the frame rather than the glass A cold metal path through the frame. Either no thermal break, or one interrupted at a junction The frame, not the glass. Upgrading the glass alone can make this worse
On the plaster reveal below the frame A cold reveal or an uninsulated kerb. The bridge is in the construction, not the skylight Insulated reveal board and a continuous vapour control layer, which is internal work
Between the two panes, unwipeable The sealed unit has failed. The desiccant is exhausted and moisture is inside the cavity A new sealed unit. This is the one case that is genuinely a fault

The three numbers behind it

Condensation is arithmetic

Three things decide whether a surface runs wet: how much moisture is in the room, how warm the room is, and how cold that particular surface is. The first two together set the dew point. Any surface below it collects water; any surface above it stays dry.

So there are three routes out, not one: take moisture out of the room, raise the surface temperature, or manage where the water goes. It also explains a result that catches people out — upgrading the glass can make a cold frame or reveal worse, because the room now runs warmer and wetter while the cold component has not moved.

Why the roof and not the windows

Warm air rises and carries its moisture with it, so the wettest air in a house is at ceiling level, and a rooflight is the only glazing sitting in that layer. A wall window meets ordinary room air at head height; a skylight meets the plume off the cooker and the bathroom door.

Position makes it worse twice over: an upright cavity suppresses convection and a near-horizontal one does not, so the inner pane of a flat rooflight runs a little cooler than the same unit would in a wall. Colder surface, wetter air.

Telling it from a leak

Timing settles it, not location. Condensation follows the calendar: it starts in November, is worst on cold clear mornings whether or not it has rained, and is gone by April. A leak follows the weather, arrives during or just after rain, often only on a driving south-westerly, and happens in any month. Condensation is clean; a leak usually leaves a mark. Two weeks of notes will separate them, and the full comparison lives on the roof lantern pages rather than here.

What to do, in order

  1. Reduce the moisture load. Extract fan run during cooking and afterwards, washing dried anywhere but under the glass, internal doors not sealing a wet room shut for days. Free, and it lowers the dew point.
  2. Move the air. Still air at the ceiling is what lets the pane run cold. A room heated evenly, with some air movement past the glazed area, keeps the inner surface closer to room temperature.
  3. Insulate the reveal and the kerb if the water is arriving on plaster rather than off metal or glass. Internal work, and usually cheaper than anything involving the roof.
  4. Check the frame before the glass. A cold frame is a frame problem and new glass in it will not cure it.
  5. Specify a warm edge spacer in any replacement sealed unit. It lifts the edge temperature and moves the perimeter band out of ordinary winter conditions.
  6. Replace the unit only when it is the unit. Misting between the panes, or an uncoated pre-2000 rooflight in a frame with no thermal break. Everything above should be ruled out first.

Dorset humidity is not the excuse it sounds like

Coastal air is damp, and it changes less than people assume. Outdoor humidity at Sandbanks or on the Quay affects the ventilation air coming in, but the large majority of the moisture in a kitchen or a bathroom is generated inside the room by cooking, washing and the people in it. A harbour location is not a reason to stop ventilating; it is a reason to ventilate deliberately rather than by leaving something ajar.

The one genuinely local effect is temperature swing. A clear, still night after a mild day — common here through autumn — gives the sharpest surface cooling, on the inside of an older skylight and the outside of a very good one.

What we do about it

On survey we look at where the water sits, whether the frame has a continuous thermal break, what the kerb is built from and whether anything insulates it, how the reveal is formed, and what the room is used for. That names a component, and often it is the reveal or the ventilation rather than the glass.

We will not promise that a new rooflight stops condensation. It cannot: the moisture in your room is half the equation, and a room that dries washing under the skylight will find the next-coldest surface. What we will do is name what is cold and why, in writing — including where the honest finding is that the unit is sound.

Our installation work carries a ten-year workmanship guarantee — a workmanship guarantee, plainly, and not insurance backed — with a fixed price after survey. Ring 01202 923272 and describe when the water appears and where it sits, rather than how much of it there is.

Get a fixed quote

Get a fixed quote

Tell us which way your roof faces.

We will come back with a specification, not a catalogue page. If your extension faces south we will tell you the G-value we would fit and why.

  • No pressure, no doorstep sales call
  • We handle the Building Control notification
  • 10-year workmanship guarantee on every installation
  • Installations and replacements across Poole and south Dorset

Prefer to talk it through? 01202 923272