Warm edge spacers and the cold strip around the glass
Why the coldest line in a sealed unit runs round its perimeter, what a warm edge spacer changes about that, and why it is the one upgrade that cannot be added after manufacture.
Look at where the water was, not at how much there is
A rooflight running with condensation in January tells you more by its pattern than by its quantity. Water across the whole pane is a room humidity problem. Water in a band, fifteen or twenty millimetres wide, following the perimeter of every pane and stopping where the clear glass begins, is not about the room at all. That band is the spacer.
It is the single most recognisable fault pattern on a sealed unit and it is also the one most often misread as a failing skylight. The glass is fine. The unit is not leaking. There is simply a strip round the edge of it running several degrees colder than the middle, and on a cold morning that strip drops below the dew point of the room while the rest of the pane stays above it.
The spacer is doing three jobs at once
The spacer is the hollow bar running round the perimeter between the two panes. It looks like a trim. It is structural, and it carries three separate responsibilities, which is why the choice of material is a genuine engineering decision rather than a finish.
- It holds the cavity open. A fixed, even gap across the whole unit. Uneven spacing changes the optics and the thermal performance together.
- It carries the desiccant. The bar is perforated on the cavity side and filled with a drying agent that absorbs the small amount of moisture sealed in at manufacture. Its capacity is finite, and when it is exhausted the unit mists.
- It carries the seals. A primary seal of butyl against gas loss and moisture ingress, and a secondary structural seal holding the sandwich together. Both are applied against the spacer.
And it does one thing it is not meant to: it conducts. Any material spanning from the cold outer pane to the warm inner one is a thermal bridge, all the way round, on every pane in the roof.
What the materials actually change
| Spacer type | Thermal behaviour | Practical consequence |
|---|---|---|
| Aluminium box | Highly conductive. The original design and still in circulation on older units | A cold band round every pane, reliably wet on winter mornings. Cheap, durable, and the reason the warm edge category exists |
| Thin-walled stainless | Far less conductive than aluminium because the wall is thin and the alloy conducts poorly | A genuine warm edge in a metal bar, with metal’s durability at the seal. Common where longevity matters |
| Polymer and composite hybrids | A plastic body, usually with a thin metal or foil vapour barrier to hold the gas | The lowest conduction of the common types. Performance depends on the barrier surviving handling and manufacture |
| Flexible foam and thermoplastic | Applied as a bead rather than a bar, with desiccant built into the material | Very low conduction and no corners to fail. More sensitive to manufacturing consistency |
The phrase “warm edge” is a category rather than a product, and it does not tell you which of these you are getting. That is worth pinning down on the order, because you are buying an outcome at the perimeter and the outcomes across the category are not identical.
Psi: the number that does not make it onto the quote
The centre of a pane loses heat at a rate per square metre, which is the U-value. The edge loses heat at a rate per metre of perimeter, and that is a different quantity with a different unit. It is called a linear thermal transmittance, written psi, and it is measured in watts per metre per degree.
Psi is how the spacer gets into a whole-unit U-value in the first place. The calculation takes the centre-pane performance, adds the edge effect over the length of the perimeter and the frame over its area, and weights all of it by area. That is why a whole-unit figure is always worse than the centre-pane one, and why the gap between them is a rough measure of how good the edge and the frame are.
Why the edge counts for more on a skylight than on a window
Rooflights are small and there are several of them. Perimeter scales with the linear dimension while area scales with the square of it, so the smaller the pane, the more metres of cold edge there are for each square metre of glass. Three modest rooflights in a row have far more perimeter than one large pane of the same total area, and every metre of it is edge.
The coldest air in the room is not near a window. It is at the ceiling that the warmest, wettest air in a house collects. A cold perimeter strip in a wall meets ordinary room air; the same strip overhead meets the wettest air in the building, which is why the same spacer produces more visible condensation in a roof than in a wall.

The edge is also what keeps the unit alive
Everything that eventually kills a sealed unit happens at its perimeter. The gas fill leaves through the edge seal. Moisture enters through the edge seal. When the desiccant is finally saturated, the misting that appears between the panes is the visible end of a process that started there years earlier.
So the spacer and seal are two arguments in one. Thermally, a warm edge lifts the glass edge temperature and moves the condensation band out of ordinary winter conditions. In terms of service life, a well-made dual-sealed edge is what decides whether the unit reaches twenty years or twelve. Choosing on the first argument and ignoring the second is how people end up with a warm, short-lived rooflight.
What a misted unit means, and whether it can be replaced without the frame, belongs to the failed and misted rooflight pages rather than this one.
It cannot be retro-fitted. That is the point of this page
A spacer is sealed inside the unit at manufacture and there is no way to change it afterwards. Not by a glazier, not by taking the unit out, not by any coating or film. The only route to a warm edge in an existing rooflight is a new sealed unit — which on some frames is possible without replacing the whole skylight, and on others is not.
That is why the spacer belongs on the order alongside the glass make-up, and why it is worth ten seconds of a conversation that is otherwise entirely about U-values and coatings. It is a decision with a twenty-year consequence taken in the week before manufacture.
Salt, ultraviolet and the edge at the harbour mouth
Exposure acts on the edge before it acts on anything else. At Sandbanks, Studland and Mudeford the wind carries salt off open water with no fetch break, and a rooflight sits in the one plane that gets the full sun as well. The secondary seal is a polymer, ultraviolet degrades polymers, and a horizontal unit takes more ultraviolet than a vertical one ever does.
There is a second, purely mechanical load. A sealed cavity breathes with temperature and pressure: the panes flex outwards on a hot afternoon and inwards on a cold clear night, and every cycle works the seal. A rooflight lying flat under an open sky sees bigger swings than a wall window on the same house, which is why rooflight sealed units generally have a harder life than the windows below them.
For roofs in that zone we put the edge seal at the top of the specification, ahead of the fill and sometimes ahead of the coating. A unit that fails at its edge after eight years has thrown away whatever was paid for the glass inside it. Inland at Broadstone, Creekmoor and Canford Heath that pressure is much lower, and ordinary good practice is genuinely enough — specifying marine-grade everything on a sheltered heathland roof is an overcharge and we will say so.

What to ask before the unit is ordered
- Which spacer, by name. Not “warm edge” — the actual type, so it can be compared against another quote.
- Is the unit dual sealed. Primary butyl against gas loss, secondary for structure. This is what decides service life.
- Is the whole-unit U-value calculated with that spacer. A figure lifted from a different build-up is not a figure for your rooflight.
- What is the warranty on the sealed unit itself, as distinct from the frame and from the installation, and what conditions it carries.
- What happens at the frame. A warm edge inside a frame with a cold metal path through it still gives a wet line, one component further out.
- What happens at the kerb and the reveal. Insulated to meet the frame, with a continuous vapour control layer, or the cold band simply moves onto the plaster.
What we specify, and what we will not promise
A warm edge spacer in a dual-sealed unit is our default on every rooflight we fit, at every size, in every zone. It is not an upgrade line on the quotation and it is not optional at the harbour mouth. Alongside it the quote names the glass make-up surface by surface, the frame’s thermal break, the kerb insulation detail and the exposure zone.
We will not tell you a warm edge will stop condensation. It will not, because condensation is set by the moisture in your room as much as by the temperature of the glass, and a room that dries washing under a skylight will find the next-coldest surface. What a warm edge does is lift the edge temperature so that ordinary winter mornings stop producing the band, and that is the claim we are prepared to make.
Our installation work carries a ten-year workmanship guarantee, stated plainly as a workmanship guarantee and not insurance backed. Sealed unit warranties are the manufacturer’s. Ring 01202 923272 and describe where the water sits — the pattern names the component, and it is frequently a cheaper component than the one people expect.
Related reading
Argon and krypton fills matter less than the brochure suggests
The cheapest line on the specification is usually the loudest Argon fill appears on almost every glazing quotation in the…
Condensation on the inside of the glass is a humidity problem
A week with a hygrometer settles it faster than an argument Almost every conversation about a wet skylight starts in…
Do rooflights cause draughts?
A correctly installed one should not. When a skylight is blamed for a draught it is almost always one of…
Do rooflights help with damp in a room?
With one kind of damp, and only if it opens. A skylight does nothing whatever for rising or penetrating damp…
Do rooflights lose more heat than walls?
Per square metre, yes, and it is not close. Any glazing loses heat several times faster than the insulated fabric…
Do rooflights make a room colder in winter?
No, not a modern one. A well-specified rooflight in a well-detailed opening adds heat loss in the same way any…