Solar control coatings: how they filter without dimming the room
How a solar control coating separates the heat in sunlight from the light in it, the selectivity ratio that tells you whether a coating is any good, and where on a Poole roof the coating earns nothing.
Sunlight is not one thing, and that is the whole trick
If sunlight were a single substance, filtering the heat out of it would necessarily darken the room by the same proportion, and every solar control product would be a compromise of the same size. It is not a single substance, and that is what makes a coating worth specifying rather than simply tinting the glass.
Roughly speaking the energy arriving at the roof splits three ways. A small slice is ultraviolet, carrying little heat but doing most of the fading. Around half is visible light — the part you are buying a skylight for. The rest is near infrared, which is invisible, carries a large share of the heat and contributes nothing whatsoever to how bright the room looks.
A solar control coating exists to reject the infrared while letting as much of the visible through as it can. Do that well and the room stays bright while a substantial part of the heat never arrives. Do it badly and you have sunglasses on the ceiling.
Selectivity: the ratio that says whether a coating is any good
Two numbers describe a coated unit. Light transmittance is the share of visible daylight it passes. The g-value is the share of total solar energy it passes. Divide the first by the second and you have the selectivity ratio, and that single figure is the most useful thing on the datasheet.
A ratio near 1 means the coating removes light and heat in equal measure, which is what a plain tint does — it dims the room as much as it cools it. A ratio meaningfully above 1 means it is removing more heat than light, which is the entire point of a modern coating. The higher the ratio, the more summer relief you get for each unit of daylight surrendered.
One question, better than a brochure
Ask for the light transmittance and the g-value of the specific unit, from the manufacturer’s declaration, and divide one by the other yourself. That comparison is meaningful across brands in a way that product names and marketing tiers are not. We will not quote you a ratio we have not read off a declaration, because an invented figure here is the one that would actually cost you money.
Three families, three different bargains
Solar control is not one technology. The three approaches behave differently, look different from inside and below, and age differently.
| Approach | How it rejects heat | What it does to the room | Where it belongs |
|---|---|---|---|
| Body-tinted glass | The glass itself is coloured through its thickness and absorbs energy | Dims and colours the daylight. Much of the absorbed heat is handed on inwards anyway | Largely superseded. Occasionally a match for existing glazing rather than a performance choice |
| Hard-coat, pyrolytic | A coating fired onto the glass during manufacture, bonded and durable | Moderate selectivity, often a faint tint. Tough enough to face outward | Exposed surfaces, and self-cleaning duty on the outer face |
| Soft-coat, sputtered | Layers including silver, applied under vacuum, tuned to reflect infrared | The highest selectivity available. Near-neutral versions are hard to detect from inside | Inside the sealed unit only, on surface 2, where the cavity protects it |
| Applied film | A polyester layer stuck to finished glass, mostly absorbing rather than reflecting | Visible dimming for the heat removed, and often a mirrored look from outside | Mitigation on a sound unit you are not ready to replace. Never a specification |
The important row is the third. A soft-coat sputtered layer cannot survive exposure — it needs the sealed cavity to protect it — which is why solar control is a decision made before the unit is manufactured and not one that can be revisited afterwards.
Why surface 2, and not any of the others
A double-glazed unit has four glass surfaces, numbered from outside in. The solar control coat goes on surface 2: the cavity-facing side of the outer pane. It is the first surface the energy meets that is capable of carrying the coating, and rejecting energy there turns it around while it is still on the cold side of the cavity.
Put the same coating on surface 3 or 4 and it still rejects infrared, but by then the energy has already crossed into the unit or into the room, and a good share of what the coating absorbs is re-radiated inwards. That is precisely the weakness of applied film, which necessarily ends up on surface 4 — the room side of the inner pane, the worst available position. The full comparison of coating against film sits on the energy efficient rooflights page.
The low-emissivity coat is a separate layer with a separate job and it lives on surface 3, keeping room-side heat on the room side. A unit can carry both, and in a south-facing Poole kitchen it usually should.

Neutral, tinted, reflective: what other people see
Modern neutral coatings are close to colourless from inside. Older or heavier products carry a cast — blue, bronze or grey — and a cast overhead is more noticeable than the same cast in a wall window, because a skylight is what lights the room’s whole ceiling plane and every white surface reports the colour back to you.
From outside the question is reflectance. A high-reflectance coating reads as a mirror in daylight, which on a rear extension nobody sees is irrelevant, and on a visible roof slope is not.
In Poole Old Town and the Quay conservation area, and on any listed roof, the appearance of the glass is a planning matter and not only a comfort one. A mirrored or strongly tinted pane on a visible slope is exactly the detail a conservation officer notices. Where a coating is needed on a sensitive roof we specify the most neutral, lowest-reflectance option that does the job, and we do not predict what any authority will accept. Consent is assessed on merit and never assured. The conservation rooflight pages set out how those applications are actually put together.
Self-cleaning is a different coating doing a different job
Self-cleaning glass gets bundled into the same conversation and it is unrelated. It is a hard pyrolytic coat on surface 1, the weather face, and it works in two stages: sunlight breaks down organic dirt on the surface, and rain then sheets across the pane rather than beading, carrying the loosened dirt off.
It has conditions attached. It needs ultraviolet to work, so a permanently shaded pane gets less from it. It needs rain to run rather than sit, which is why manufacturers commonly want a minimum pitch and why a near-level pane undercuts its own coating. And it reduces cleaning rather than removing it.
It can be combined with solar control in the same unit, because the two coatings sit on different surfaces. On a rooflight you cannot reach, it is frequently the more valuable of the two.
What a coating cannot do
- It cannot fix an area problem. A coating reduces the energy per square metre. If the glazed area is large against the floor beneath it, the total arriving is still large and no coating recovers that.
- It cannot remove stored heat. Heat already in the floor and the walls comes out in the evening regardless. That is a ventilation job.
- It cannot cut glare on its own. Glare is about brightness contrast and the position of the sun. A room can be comfortably cool and still unusable at a screen without a blind.
- It cannot be added later. Not to an existing sealed unit. Film is a different product with a different result and it commonly ends the unit’s warranty.
- It cannot tell winter from summer. The rejection is permanent, so every July benefit is paid for with a January cost.
- It cannot beat external shade. Anything that stops the energy before the glass outperforms anything that acts at the glass, and both beat a blind inside the room.

Under the pines, the right coating is less coating
Canford Cliffs and Branksome Park are the case where the specification should come down rather than up. Mature pine, a great deal of it under tree preservation orders, shades those roofs permanently — and because pine is evergreen it shades them in January exactly as it does in August. The canopy is external shading, already installed and not going anywhere.
Put a heavy solar control coating under that canopy and you buy shade twice. The summer load was already intercepted; what the coating then removes is the winter daylight from a room that was short of it to begin with. The sensible specification there is a clear or lightly coated low-emissivity double with the highest light transmittance available, and a self-cleaning outer pane, because needle fall, resin and leaf litter dull a skylight faster than owners expect and the pane is usually out of reach.
The money that would have gone into solar control goes into the kerb insulation and the edge seal instead. It is one of the few decisions on this site where the honest answer is to spend less, and we would rather say it than sell a coating that makes a shaded room darker.
Where it does earn its place across the service area
| Roof | Solar control case | What we specify instead or as well |
|---|---|---|
| Flat or low-pitch, open sky, Sandbanks or the harbour mouth | Strongest. No shade, full sky dome, and the midsummer sun close to square on | Neutral soft-coat on surface 2 plus low-emissivity on surface 3, and A4 stainless fixings for the exposure |
| West-facing pitched roof window, Parkstone or Penn Hill | Strong. Late sun arrives near head-on at the worst time of day | Coating plus an external blind, because the low afternoon sun is a glare problem as well as a heat one |
| North-facing slope, any zone | None. There is no direct solar load worth paying to block | Clear low-emissivity double, highest light transmittance, budget into the U-value and the kerb |
| Under mature pine, Canford Cliffs or Branksome Park | Negative. The canopy already shades, all year | Light coating at most, self-cleaning outer pane, and accessible drainage channels for the needle fall |
| Visible slope in a conservation area, Poole Old Town | Conditional on appearance before performance | Lowest-reflectance neutral option that works, declared to the authority rather than assumed |
Specifying it so it arrives right
A sealed unit is made once. The coating, the surface it sits on, the spacer and the fill are all fixed at manufacture, and none of them can be altered on the roof. So the specification has to be right on the order rather than on the conversation.
What goes on our quotation: the product and its surface position, the manufacturer’s declared light transmittance and g-value, the low-emissivity coat and its surface, the spacer type, the laminated inner pane that Part K requires over any place people stand, and the exposure zone the roof sits in. Where a figure is the manufacturer’s, it is labelled as theirs and it governs.
Our installation work carries a ten-year workmanship guarantee — a workmanship guarantee, plainly, and not insurance backed. The price is fixed in writing after survey. If a room is already too bright or too hot and you are weighing a coating against a blind, ring 01202 923272; on a shaded roof the answer is often neither.
Related reading
Argon and krypton fills matter less than the brochure suggests
The cheapest line on the specification is usually the loudest Argon fill appears on almost every glazing quotation in the…
Condensation on the inside of the glass is a humidity problem
A week with a hygrometer settles it faster than an argument Almost every conversation about a wet skylight starts in…
Do rooflights cause draughts?
A correctly installed one should not. When a skylight is blamed for a draught it is almost always one of…
Do rooflights help with damp in a room?
With one kind of damp, and only if it opens. A skylight does nothing whatever for rising or penetrating damp…
Do rooflights lose more heat than walls?
Per square metre, yes, and it is not close. Any glazing loses heat several times faster than the insulated fabric…
Do rooflights make a room colder in winter?
No, not a modern one. A well-specified rooflight in a well-detailed opening adds heat loss in the same way any…