G-value and solar gain: why a summer room refuses to cool down

Why a room under glass peaks in the evening rather than at noon, what a g-value does and does not count, and the order in which overheating is actually fixed.

U-value and g-value pull in opposite directionsU-value measures heat leaving through the unit; g-value measures solar energy coming in. A coating that cuts summer gain also cuts the winter daylight and warmth a room receives, which is why the right answer depends on orientation and on what shades the roof.solar energy ing-valueheat outU-valueglazed unitlowering one usually raises the other

Nine in the evening, and the room is still the hottest in the house

This is the complaint, almost word for word, every July. The sun left the roof hours ago. The rest of the house has cooled. The room under the glass has not, and by bedtime it is still several degrees ahead of everywhere else.

People reach for the glass first, and the glass is part of it. But the timing is the giveaway. If the glass were the whole story the room would peak when the sun was at its strongest and fall away with it. A room that peaks hours late is not being heated by the sun any more. It is being heated by what the sun left behind.

What a g-value counts

The g-value — also written as solar factor, total solar energy transmittance, or in imported literature as SHGC — is the share of the sun’s energy striking the glass that ends up inside the room. It runs from 0 to 1 and it counts two routes: energy that passes straight through, and energy absorbed by the glass that is then re-radiated inwards.

That second route is why an absorbing tint is a weaker tool than a reflecting coating. Tinted glass takes energy out of the beam, but a good deal of the heat it absorbs is handed on to the room afterwards rather than being sent back out. A coating that reflects on the cavity side of the outer pane turns the energy around before it is inside the unit at all.

Number Direction it describes What people confuse it with
U-value Heat conducted outwards, all year, day and night Assumed to cover summer performance. It does not describe solar gain at all
G-value Solar energy passing inwards, only while the sun is on the glass Read as a quality score, where in fact low is only better for half the year
Light transmittance Visible daylight passing inwards Assumed to fall in step with the g-value. A selective coating deliberately separates the two

Why a roof collects far more than a wall

A south-facing wall window catches the sun for part of the day and at an angle. In midsummer, when the sun is highest, it catches rather less of it, because the beam arrives glancing across the vertical face rather than square on.

A flat rooflight is in the opposite position. At three to five degrees of pitch it faces the entire sky dome, takes the midsummer sun close to square on around the middle of the day and does so whichever way the house is turned. The season that is kindest to a south wall is the season that is hardest on a flat skylight. Homeowners who have only ever had wall windows are not being careless when this surprises them; the geometry genuinely reverses.

Pitch is what decides it. A roof window at thirty to forty-five degrees behaves far more like a wall window, with a strong aspect and a worst case in the late afternoon on a west-facing slope. A near-flat unit has almost no aspect at all, which is why orientation advice that works for windows transfers badly to rooflights.

The heat the sun leaves behind

Why the peak arrives after the sun has gone

Solar energy entering a room does not stay in the air. It lands on floors, walls and worktops and is absorbed by their mass. A screed floor, a plastered blockwork wall or a run of stone worktop takes hours to warm and hours to let go again. So the room’s air temperature keeps climbing after the input has stopped, and peaks in the evening.

That lag is the whole reason an overheating complaint is rarely solved by the glass alone. Cutting the input reduces how much goes into store. Getting the heat back out of store is a ventilation problem, and the two have to be solved together.

It also explains the run of bad days. One hot day and one cool night, and the mass discharges overnight and the room starts even. Four hot days and four warm nights, and each morning begins warmer than the last. By the fourth day the room is uncomfortable from breakfast and no change to the glass would have prevented it.

G-value and solar gain: why a summer room refuses to cool down
A warm-edge unit on a cold morning: clear glass, dry reveal.

It is an area sum before it is a glass sum

The g-value is a rate. What arrives in the room is that rate multiplied by the glass area and by how much sun that area actually receives. Doubling the glazed area doubles the input, and no plausible coating recovers a doubling.

This is the most common route into an overheating room, and it happens with the best intentions: a rear extension is designed for light, two large skylights go in over an open-plan kitchen, and the glazed area ends up a substantial fraction of the floor beneath. The daylight is genuinely wonderful in March. The same arrangement in July is a greenhouse with a dishwasher in it.

The corresponding daylight question — how much rooflight area a room actually needs before more stops helping — has its own page in this cluster, and the honest answer there frequently reduces the glazed area rather than the g-value.

Night purge, and why it fails in a Poole kitchen

Getting stored heat out overnight is the cheapest cooling there is: open up late, let cooler night air run through, and start the next day from a lower base. It works well in principle and there are four ordinary reasons it fails in practice.

Why the purge fails What answers it
Nothing high enough to open Hot air collects at the ceiling. An opening at low level alone cannot reach it; an opening rooflight at the high point can
One opening, so no path Air needs an inlet and an outlet. A single opening ventilates by diffusion and very little else
Security, so nothing is left open A rooflight is the one opening in most houses that can be left ajar overnight without being reachable from the ground
Rain, so it gets shut at eleven A rain sensor closes an electric unit on its own; the trade-off is that sea mist off the harbour can trigger it

Ventilation is a subject of its own and the electric rooflight cluster covers the hardware properly. It belongs here because a purge that works changes the glass specification you need, and a purge that cannot work makes the glass carry the entire load.

What a lower g-value costs you in January

Solar gain is not a defect. From October to March the sun coming through a skylight is free heating arriving exactly where a room with a glazed roof loses it. Specify hard against summer and you pay for it in a darker, colder winter room, and the payment is every year rather than only in the four weeks that prompted the decision.

Typical figures give the shape of the trade-off: clear double glazing passes something near 0.6 of the incident solar energy, a neutral solar control coating lands around 0.4, and a high-performance coating nearer 0.3. Those are indicative bands rather than specification, and the manufacturer’s declared g-value for the actual unit is what governs.

The decision is asymmetric, and it should be made that way. A room that overheats for three weeks in July is a real problem with several non-glass fixes available — shading, purge, reducing the glazed area. A room that is dim and cold from November to February has only one fix, and it is replacing the glass. That is the argument for solving summer with shading and ventilation first, and reaching for a low g-value only when those have been used up.

G-value and solar gain: why a summer room refuses to cool down
The kerb is measured before anything is ordered.

Under the Branksome Park pines, the sum is already done

Canford Cliffs and Branksome Park sit under mature pine, much of it protected, and a pine canopy is evergreen. It shades a roof in August and shades it just as thoroughly in January. That is external shading — the most effective kind, because it stops the energy before it reaches the glass — and it is already installed and free.

Specifying a heavy solar control coating under that canopy pays for shade twice and takes the winter daylight along with it, in a room that was already short of light because the trees do not stop in December. On those roofs the sensible specification is a clear or lightly coated low-emissivity double with high light transmittance, and the budget that would have gone into solar control goes into the kerb insulation and a self-cleaning outer pane instead, because needle and resin fall cut daylight more than owners expect.

Out on the exposed roofs at Sandbanks and the harbour mouth nothing shades anything. There the solar control case is at its strongest, and it is the seal and the fixings rather than the coating that decide how long the unit lasts.

The order to fix an overheating room in

  1. Measure before deciding. A cheap logger in the room for a fortnight tells you when it peaks. An evening peak is stored heat; a midday peak is direct gain. They have different fixes.
  2. Open the purge path. A high-level outlet and a low-level inlet, used overnight. Free, reversible, and it addresses the stored heat that glass cannot.
  3. Shade externally where you can. An external blind, a screen or a planted canopy beats anything fitted inside the room, because the energy never arrives.
  4. Look at internal gains. An oven, a hob and a fridge condenser all run in the same room, in the same weather, and they are usually counted last if at all.
  5. Then consider the glass. A solar control coating in the sealed unit, specified on surface 2, with the winter cost accepted deliberately rather than discovered later.
  6. Reduce the glazed area last, and only on a new design. On a project still on paper this is the most effective move available and the only point at which it is cheap.

What the survey settles, and what we will not claim

On site we take the glazed area against the floor area, the pitch, the aspect, what shades the roof and at what time of year, whether a purge path exists or could be made, and what else in the room generates heat. That produces a specification for a particular roof rather than a default.

We will not put a temperature reduction or a payback period in writing. Both depend on occupancy, weather and habits we cannot model honestly, and a figure invented to close a sale is worth nothing to you in August. What we will put in writing is the unit, the declared g-value and light transmittance from the manufacturer, the surface the coating sits on, and a fixed price after survey. Our installation carries a ten-year workmanship guarantee, stated plainly as a workmanship guarantee and not insurance backed.

If the room is already too hot, ring 01202 923272 and tell us what time of day it peaks. That one detail sorts the cases that need glass from the far larger number that need a way to let the heat out.

Get a fixed quote

Get a fixed quote

Tell us which way your roof faces.

We will come back with a specification, not a catalogue page. If your extension faces south we will tell you the G-value we would fit and why.

  • No pressure, no doorstep sales call
  • We handle the Building Control notification
  • 10-year workmanship guarantee on every installation
  • Installations and replacements across Poole and south Dorset

Prefer to talk it through? 01202 923272