Why is there water inside the double glazing of my rooflight?
Because the edge seal failed some time ago, and the unit has been quietly breathing damp air in and out ever since. The desiccant that was absorbing that moisture is now saturated, so what used to appear as a faint haze on cold mornings has become liquid water collecting in the bottom of the cavity.
Visible water is not a different fault from misting. It is the same fault, further along. And it puts a date on the failure: by the time there is standing liquid in the gap, the seal has usually been letting go for several seasons.
How liquid gets into a sealed space
- Morning sun warms the cavity. The gas inside expands and pushes outward against both panes and the perimeter seal.
- Late afternoon the glass cools and the cavity contracts. Overnight, radiative loss to a clear sky pulls the outer pane below air temperature and exaggerates it further.
- Where the primary seal has thinned, each of those cycles draws a small breath of outside air in and pushes cavity air out. Over a year that is several hundred meaningful movements.
- Every breath of outside air brings water vapour. The desiccant in the spacer bar takes it, and its capacity is finite and cannot be regenerated.
- Once the desiccant is spent, the dew point inside the cavity rises steeply and the moisture has nowhere to go but onto the glass.
- Condensed vapour runs down the inner faces and collects at the lowest point, which on a rooflight is a long low edge rather than a corner.
The stages, in order
| Stage | What you see | How long it has been going on |
|---|---|---|
| Early | Light haze on cold mornings that clears by lunchtime | The seal has been failing for a while. The desiccant is nearly spent |
| Established | Haze that no longer clears, thickest at one corner or along one edge | Usually a year or two past the first symptom |
| Liquid | Visible droplets or a pool of water inside the gap | Several seasons. Water has been condensing and evaporating repeatedly |
| Marked | Hard white tide lines and mineral deposits across the lower glass | Years. The deposits are usually permanent |
Why it sits at the bottom and leaves a line
Water in a wall window drains to a short sill and the tide mark is small. In a rooflight the low edge is the full width of the unit, so the water spreads along it, and because overhead glazing is at a shallow pitch the pool is broad and thin rather than deep. Each summer it evaporates and each winter it comes back, and every cycle leaves behind whatever minerals were dissolved in it. That is what produces the hard white line that will not shift.
It cannot drain out, and it should not be drilled
Why we will not vent an overhead unit
There is a treatment on the market that drills the unit, flushes the cavity and fits small vents so it can breathe. It does clear the appearance for a while. It also converts a sealed unit into an open one: the gas fill is gone, the desiccant is not replaced, and the cavity is now connected to outside air and everything it carries.
On a wall window that is a compromise. On overhead glazing, where the drilled edge is exactly where water stands all winter, it is a poor idea, and where tide marks have already etched the coating the appearance does not fully return anyway. We would rather quote the new unit and tell you honestly that on a mechanically glazed frame it is the smaller job than take money for something that lasts a season.
What the water does to the glass
The cavity faces of both panes normally carry a low-emissivity coating, and that coating is a fine metallic layer designed to sit in a dry, sealed space. Standing water attacks it. The result is patchy, iridescent staining that remains after any amount of drying, and in advanced cases fine etching of the glass surface itself. It is the clearest single reason a failed unit cannot be restored: even if you could get the water out, you could not get the coating back.
Is it dangerous?
No. Toughened glass does not lose strength because the cavity has flooded, and a laminated inner pane keeps its interlayer. Water inside the unit cannot get into the room, because the inner pane is a continuous sheet of glass. There is no electrical risk and no structural one, and nothing about it makes the roof less weathertight. It is a component that has reached the end of its life in an obvious and ugly way.
Flat rooflights show it more than pitched ones
The shallower the pitch, the more obvious this gets. A pitched roof window sheds water down a steep inner face, so a failed unit tends to look streaky rather than pooled. A flat glass rooflight or a lantern pane sits at a shallow fall, so the water lies across the lower glass in a broad sheet that is visible from everywhere in the room. It is also why flat units fail this way sooner: the same shallow fall means rainwater outside stands over the perimeter seal instead of running off it. Where there is no fall at all, which we still find on 1990s Poole extensions, the low edge of the unit has effectively been sitting in a puddle for twenty years.
What to do now
Nothing urgent. It is not a leak and it is not a hazard, and it will not suddenly get worse. Photograph the low edge along its length and each corner from inside, with the room lights off, and send them to 447880284133, or ring 01202 923272. What we will want to establish is whether the frame can keep its place and take a new unit, or whether the whole skylight is going, and whether the fall and the drainage that let water stand on that edge need correcting at the same time. The survey ends in a fixed written price, and our installation carries a ten-year workmanship guarantee given directly by us, which is not insurance backed.
Related reading
Are 1990s rooflights on Poole extensions worth replacing now?
In most cases yes, and usually not for the reason people expect. A 1990s unit that has misted is finished…
Can a leaking rooflight be resealed instead of replaced?
Sometimes, where the leak is at a gasket, a termination or a joint that can genuinely be renewed. But the…
Can a misted rooflight be repaired?
Sometimes, but not in the way most people mean. The misting itself cannot be cured, because the fault is inside…
Can a misted unit be replaced with a larger one?
Yes, and it is often worth doing while the roof is open. But be clear what you are agreeing to:…
Can a rooflight be replaced in one day?
The fitting usually is, yes. One rooflight, on a roof that can be reached, onto a kerb that turns out…
Can an old dome rooflight be swapped for flat glass?
Yes, and it is one of the replacements people are most pleased with afterwards. The work is usually straightforward, because…