Why did my Sandbanks rooflight fail after only ten years?

The short answer

Because something in the original build-up was wrong for a roof, and because the roof is on the most exposed ground in the service area. Ten years is early even at Sandbanks. The common finding is a sealed unit specified as a window and fitted overhead on the spit, where ultraviolet, salt and driven rain arrive together with nothing in the way. The position made it worse; the specification made it possible.

How a sealed unit fails and mistsA sealed unit holds dry air or argon between two panes, kept dry by desiccant in the spacer bar. Daily heating and cooling pumps the cavity; once the edge seal loses its grip, moist air is drawn in, the desiccant saturates, and the misting that appears between the panes cannot be cleaned because it is on the inside.cavity: dry air or argonspacer with desiccantedge sealmisting sits between the panes, so it cannot be cleaned offmoist air

Ten years is a diagnosis, not bad luck

A well-made overhead unit in a well-built opening should be going about its business at ten. When one is not, there is a reason, and it is nearly always something that was decided before the rooflight ever reached the roof. Knowing which reason matters, because a replacement specified without knowing it is a replacement that will fail on the same timetable.

What the spit does that four miles inland does not

Sandbanks is a sand spit with open water on both sides and no fetch break on the prevailing south-westerly. That is not a description of a nice view, it is a description of a load. Salt aerosol is on the roof continuously rather than occasionally. Driven rain arrives horizontally and goes up an upstand as readily as it lands on a deck. There is no shading, so ultraviolet exposure at the perimeter seal is full for the whole day. And wind-blown sand abrades coatings and glass surfaces in a way that simply does not happen at Broadstone or Canford Heath. A unit that would run twenty years on the heathland edge is commonly finished by fifteen here, and by ten if it was the wrong unit to start with.

The four candidate causes, ranked for this address

Cause Why it is likely here What you would see
A window make-up fitted overhead The usual secondary sealant on a volume window unit is not stable in full sunlight A perimeter seal that has darkened, softened or shrunk back behind shallow edge cover
Standing water at the low edge A lost or absent fall holds water against the one part that must stay dry A tide mark low on the glass and dirt collected along the same edge
Corrosion at the fixings and frame Salt attacks what holds the assembly together, not the sealant itself Blistered coating at cut ends and fixings, chalky white frame surfaces
An upstand too low for the exposure Driven rain with no fetch break overtops a height that is adequate inland Staining on the reveal below, worst on the south-west corner

What the evidence on your own unit will show

  1. Look along the perimeter through the glass. A seal that has retreated from the spacer, darkened or gone patchy is the material telling you which sealant it was.
  2. Measure how much frame actually overlaps the edge of the sealed unit, because shallow edge cover is the detail that lets sunlight onto a seal that cannot take it.
  3. Find the tide mark. Where it sits tells you whether water has been standing, and on which side.
  4. Look for the spacer bar between the panes and any stamp on it, and for the toughening mark etched into a corner of the glass. Between them they usually date and identify the unit.
  5. Photograph the frame at each corner and at every visible fixing, because corrosion shows as a lifted coating long before it shows as rust.
  6. Check the upstand height above the finished covering on all four sides separately, since roofs settle and one corner is generally lower.

Is there anything left of a warranty?

Possibly, and it is worth ten minutes finding out before spending anything. Sealed units are normally supplied with a manufacturer’s guarantee for a defined period and under stated conditions, and those conditions matter: how the unit was installed, whether the edge was detailed as the manufacturer required, and whether the original order paperwork still exists. Dig out the original invoice and any specification sheet. We will read them with you and tell you honestly whether there is a claim worth pursuing, including when the answer is that there is not.

What actually lasts on the spit

The rule, and the exception

The rule. Overhead glazing here is specified as marine overhead glazing: a secondary seal that is stable in ultraviolet, generous edge cover so the perimeter is not sunbathing, a warm-edge spacer, a genuine fall so the low edge sheds, an upstand height that suits driven rain off open water, and fixings and coatings chosen for salt rather than for price.

The exception. Every word of that is wasted money four miles inland. At Broadstone, Creekmoor, Canford Heath, Ferndown or Wimborne the salt is not in the air, the ordinary specification is the correct specification, and a firm selling marine-grade fittings into a sheltered heathland garden is selling a defence against a threat that is not there. We name the exposure zone your roof sits in before we specify anything, and we say when the plain answer is the right one.

Even the right specification is shorter-lived here

This is the part nobody enjoys hearing. A properly specified overhead unit on the spit will still not match the life of the same unit at Wimborne, because the loads are genuinely higher and no product removes them. What a correct specification buys you is the difference between ten years and a long, ordinary life, not immunity. Anyone promising you a unit that will not fail in that position is selling something they cannot deliver, and the promise is worth precisely nothing when the day comes.

What to do next

Photograph the perimeter, the corners and any tide mark, and send them to 447880284133, or ring 01202 923272. We will tell you which of the four causes the evidence points at, whether the original supplier is worth a letter, and what a replacement in that position actually needs. The survey produces a fixed written price; we will not give you a figure for a Sandbanks roof over the phone, because the exposure, the upstand and the access all move it and none of them is visible from a description. Our installation work carries a ten-year workmanship guarantee, given directly by us, which is not insurance backed.

Get a fixed quote

Get a fixed quote

Tell us which way your roof faces.

We will come back with a specification, not a catalogue page. If your extension faces south we will tell you the G-value we would fit and why.

  • No pressure, no doorstep sales call
  • We handle the Building Control notification
  • 10-year workmanship guarantee on every installation
  • Installations and replacements across Poole and south Dorset

Prefer to talk it through? 01202 923272