Is a misted rooflight still weatherproof?
Almost always, yes. A failed edge seal is a failure of the cavity between the panes, not of the line that keeps water out of your roof. The weatherproofing is done by the gaskets, the frame, the upstand and the flashing, and none of those is affected by the unit misting up.
That is why we say a misted skylight is not an emergency. It is unattractive, it costs a little in heat, and it can wait for a sensible date rather than a wet Tuesday in January.
Where the weather line actually is
| Component | What it keeps out | Affected by a failed seal? |
|---|---|---|
| Perimeter gasket or cap seal | Driven rain at the joint between glass and frame | No. Same age, so it may be tired, but the two failures are independent |
| Frame and drained rebate | Incidental water, which is led back out through drainage slots | No |
| Upstand or kerb | Standing and driven water at deck level | No |
| Flashing and covering junction | Everything arriving from the roof surface | No |
| The sealed unit edge seal | Water vapour, from the cavity between the two panes only | This is the part that has failed, and it is inside the glass |
Read down that table and the point makes itself. Four separate things are keeping the rain out, and the failed component is not one of them.
What you actually lose
Three things, none of which is weathertightness. You lose daylight, gradually, as the haze thickens and then stops clearing. You lose thermal performance, partly because the gas fill has long since permeated out and partly because water in the cavity conducts heat far better than gas does. And you lose the view, which for a lot of people is the reason the rooflight was put in.
The three cases where it does signal a risk
When misting is a warning rather than a nuisance
When the gaskets have gone too. They are the same age as the unit. A failed seal does not cause a gasket to perish, but a rooflight old enough for one is old enough for the other, and a perished gasket is a weather problem.
When the misting is a band along the low edge. That pattern says water has been standing on that edge, which usually means no fall or a blocked rebate. Standing water at a perimeter is a weatherproofing issue in its own right, whatever the glass is doing.
When the inner pane is annealed rather than laminated. Some older overhead glazing was built without a laminated inner pane. That is a safety consideration rather than a weather one, and it is the argument we would put for not leaving an old unit indefinitely.
Does the glass get weaker?
No. Toughened glass does not lose strength because the cavity it forms part of has failed, and a laminated inner pane keeps its interlayer. What can happen over years is that liquid water standing in the cavity attacks the low-emissivity coating on the inner faces and leaves permanent mineral deposits, which is a cosmetic and thermal loss rather than a structural one.
The one genuine exception is a unit that has also been drilled and vented as a so-called defogging repair. A vented cavity on overhead glazing, with a hole at the edge where water stands, is a different proposition, and it is the reason we do not offer that treatment.
How long can you leave it?
Practically, as long as you can tolerate looking at it, with two caveats. The first is that tide marks and coating damage accumulate the longer liquid water sits in the cavity, so a unit left for years may end up looking worse than the replacement timetable required. The second is that if the rooflight is one of several of the same age, the others are on the same schedule, and it is generally easier to plan that than to react to it one unit at a time in February.
Leaving one through a winter on this coast
Exposure changes how quickly a tired assembly moves from nuisance to fault. On the sand spit at Sandbanks and around the harbour mouth, where the prevailing south-westerly arrives with no fetch break, the gaskets, fixings and cap seals around a twenty-year-old unit are taking a beating the glass never sees. A misted unit there is still weatherproof, but it is worth having somebody look at the perimeter rather than only the pane. Four miles inland at Broadstone or Creekmoor the same misted unit is simply a cloudy skylight, and there is no particular hurry at all. Which of those applies is the first thing we establish from your address.
What to watch for
Staining on the ceiling or the reveal around the opening, particularly if it appears during rain rather than on cold mornings. A whistle or a draught at the perimeter in a strong south-westerly. Rust streaks running down the frame from a fixing head. Any of those is a separate fault from the misting and is worth a look; the misting on its own is not.
What we would do
Establish that it is a cavity failure rather than a leak or condensation, check the gaskets, drainage and upstand while we are there, and tell you plainly whether you have a problem now or a job to plan. If the answer is that it can wait until spring, that is what you will be told. When you do want it dealt with, the survey produces a fixed written price with the glass-only and full replacement routes shown separately, and our installation carries a ten-year workmanship guarantee given directly by us, not insurance backed. Ring 01202 923272.
Related reading
Are 1990s rooflights on Poole extensions worth replacing now?
In most cases yes, and usually not for the reason people expect. A 1990s unit that has misted is finished…
Can a leaking rooflight be resealed instead of replaced?
Sometimes, where the leak is at a gasket, a termination or a joint that can genuinely be renewed. But the…
Can a misted rooflight be repaired?
Sometimes, but not in the way most people mean. The misting itself cannot be cured, because the fault is inside…
Can a misted unit be replaced with a larger one?
Yes, and it is often worth doing while the roof is open. But be clear what you are agreeing to:…
Can a rooflight be replaced in one day?
The fitting usually is, yes. One rooflight, on a roof that can be reached, onto a kerb that turns out…
Can an old dome rooflight be swapped for flat glass?
Yes, and it is one of the replacements people are most pleased with afterwards. The work is usually straightforward, because…