Yes, but less because of the mist than because of what the mist proves. Three things happen to a failed unit at the same time: the cavity gas has been slowly leaving for years, damp air has replaced it, and where liquid water reaches the low-emissivity coating that coating starts to degrade. The haze you can see is the least significant of the three. What you are losing is mostly invisible and it started long before the glass went cloudy.
Three losses, not one
People reasonably assume the water in the cavity is doing the damage. It contributes, but it arrives late. The performance of a sealed unit depends on the gas fill, the emissivity of the coating and the conduction path round the edge, and the first two of those have been quietly deteriorating for as long as the seal has been thinning.
Which loss is which
| Mechanism | What it does to performance | When it starts |
|---|---|---|
| Gas fill escaping | Argon or krypton is replaced by air, which convects more readily across the cavity | From new, slowly, through the secondary seal. Invisible throughout |
| Damp air in the cavity | Moist air conducts and convects more than dry gas, and carries heat as vapour | Once the primary seal is passing air, well before any mist appears |
| Coating degradation | A corroded low-emissivity layer stops reflecting heat back into the room | Where liquid water actually reaches the coated face, usually at the low edge |
| Edge conduction | A plain aluminium spacer conducts heat round the perimeter regardless of the glass | From new. It is a design property, not a failure |
What water does to a low-emissivity coating
The coating is a microscopically thin metallic layer on one of the internal faces, and it is on the inside precisely because it cannot survive exposure. Once liquid water is standing against it, it corrodes: usually as a dull, patchy bloom that spreads from the bottom edge upwards, and often visible as a difference in reflection rather than as a stain. When you can see that bloom, the unit has stopped doing the job it was bought for, and no amount of drying out would restore it.
Why we will not give you a figure
No numbers without the original specification
What would be needed. To tell you what a failed rooflight has lost, you would need the original make-up, the gas fill, the coating type and its position, the spacer, and a measurement taken now. Nobody has the first four for a unit fitted in the 1990s, and the fifth is a laboratory exercise, not a survey.
So we will not publish one. Any firm telling you a misted skylight has lost a stated percentage of its insulation value is quoting a number they invented, and the number is always large enough to justify the quotation attached to it. We would rather tell you what is happening and let you weigh it than sell you arithmetic.
What you actually feel in the room
Three things, in roughly this order. A radiant chill standing under the opening on a cold evening, because the inner pane is colder than it used to be and your skin reads that directly. Condensation appearing on the inside face of the glass or on the reveal, which is a symptom of a cold surface rather than of the misting. And a room that takes longer to warm through in the morning than the rest of the house. None of those is proof on its own, but together they are a better guide than the haze.
The comparison that matters
The honest comparison is not between your rooflight when it was new and your rooflight now. It is between your rooflight now and what would replace it. A current overhead unit with a warm-edge spacer, a proper coating and an intact gas fill is a considerably better piece of engineering than a 1990s unit was on its first day, quite apart from everything the old one has lost since. That gap is the real case for replacing, and it does not depend on any invented figure.
Winter under a harbour roof
The local climate makes the loss show up differently in different parts of the service area. Dorset winters are comparatively mild and comparatively wet, so the dominant complaint under a failed skylight here is condensation and a cold surface rather than raw heat loss. On a clear night the glass radiates to the sky and drops below air temperature, which is why the misting and the condensation both peak at four in the morning and ease by mid-morning. Around the harbour and on the spit at Sandbanks the wind adds to it: a cold outer pane in a continuous south-westerly stays cold, and an already failed unit has no gas left to slow the transfer. Under the pine canopy at Canford Cliffs and Branksome Park the same unit is shaded all day and therefore colder for longer, which makes the condensation more persistent even though the heat loss is no worse.
Is the heat loss alone a reason to replace?
Usually not on its own, and we would rather say that plainly. What tends to drive the decision is appearance, because a hazed rooflight is visible from every part of the room, followed by condensation, followed by the fact that the unit has failed and will not improve. The thermal gain is real and it is worth having, but it is the third argument rather than the first, and treating it as the first is how people end up with a payback calculation nobody can substantiate.
What the survey gives you
The make-up of what is proposed, in writing, with the manufacturer’s stated performance for that unit, so you are comparing a documented replacement against an undocumented original rather than two guesses. We also record whether the existing spacer is warm-edge or plain aluminium and how the perimeter is detailed, because on a good many Poole roofs the edge is doing more damage than the glass. The price is fixed in writing after the survey. Our installation work carries a ten-year workmanship guarantee, given directly by us, which is not insurance backed. Ring 01202 923272 or send a photograph taken from directly beneath the unit to 447880284133.
Related reading
Are 1990s rooflights on Poole extensions worth replacing now?
In most cases yes, and usually not for the reason people expect. A 1990s unit that has misted is finished…
Can a leaking rooflight be resealed instead of replaced?
Sometimes, where the leak is at a gasket, a termination or a joint that can genuinely be renewed. But the…
Can a misted rooflight be repaired?
Sometimes, but not in the way most people mean. The misting itself cannot be cured, because the fault is inside…
Can a misted unit be replaced with a larger one?
Yes, and it is often worth doing while the roof is open. But be clear what you are agreeing to:…
Can a rooflight be replaced in one day?
The fitting usually is, yes. One rooflight, on a roof that can be reached, onto a kerb that turns out…
Can an old dome rooflight be swapped for flat glass?
Yes, and it is one of the replacements people are most pleased with afterwards. The work is usually straightforward, because…