Rooflight and Skylight Installation Lytchett Minster

Rooflight and skylight installation in Lytchett Minster, at the sheltered head of Lytchett Bay, where the covering on your particular roof decides the job and thatch changes the answer entirely.

ZoneSpecified by exposure
10 yrWorkmanship guarantee
BCPNotification handled
Roofs and exposure around Rooflight and Skylight Installation Lytchett Minster
The sheltered side. Salt is present, but the land breaks the prevailing south-westerly.
Roofs and exposure around Rooflight and Skylight Installation Lytchett Minster
The sheltered side. Salt is present, but the land breaks the prevailing south-westerly.
Exposure zones across the Poole service areaExposure changes within about four miles. The harbour mouth and the spit take salt-laden wind with no fetch break; the Quay and Old Town are sheltered by the land behind them; the wooded cliffs add debris and canopy; inland is ordinary exposure where a marine specification is an overcharge.spitharbourwooded cliffinlandmost aggressiveordinaryabout four miles changes the specification

The quietest water in Poole Harbour

Lytchett Minster sits at the head of Lytchett Bay, a shallow, reed-fringed arm at the north-western corner of Poole Harbour where the Sherford River comes in. It is about as sheltered as harbour-side living gets in this area. There is water nearby and there is salt in the air, but it arrives as a fine haze on a still morning rather than as driven spray with a gale behind it, and the prevailing south-westerly has crossed several miles of heath, farmland and woodland before it reaches a roof here.

Exposure zone: sheltered marine, at the mild end of it. Coastal-grade coating on the frame and A4 (316) stainless on exposed fixings is a reasonable and proportionate specification here. Full severe-marine build-up — the one we write for Studland, a few miles away as the wind blows and twenty-five by road — is not justified by these conditions, and quoting it would be charging you for protection Lytchett Bay will never test.

What genuinely shortens the life of glazing in this village is not corrosion. It is shade, damp and debris, and that is a different set of decisions entirely. More on those below, because they are where the money should actually go.

Two building stocks in one village, and they need different things

Lytchett Minster is really two places sharing a name. There is an old village core of cottages and older houses, and there is the later twentieth-century and modern housing that grew around it and out along the roads towards the Bakers Arms junction and Upton. A rooflight enquiry from one of those is a different quote from the other, and we identify which one you are before discussing products.

Covering Where in the village Flashing detail What we look at first
Concrete interlocking tile Later estate and infill housing Manufacturer’s profiled kit — engineered, off the shelf, reliable Roof pitch, since most pitched roof windows are rated from about 15 degrees
Clay plain tile Older houses and the village core Plain tile kit with tile-and-a-half cuts at the reveal Batten condition and whether there is underlay, sarking or nothing behind the tiles
Natural slate Scattered, on older and on some modern builds Slate kit with soakers; slates lifted and re-hung by hand Whether the slates are nail-sick and will break on removal
Flat roof, felt or single ply Rear extensions and garage conversions of every era Insulated kerb built, weatherproofed, then measured, then the unit ordered Deck build-up and joist condition under an intact-looking covering
Thatch Older cottages, in Lytchett Minster as in most Dorset villages Normally none from us — see the panel below Whether there is an adjoining tiled or slated section that could take the glazing instead

Thatch, where the answer is usually no

A rule we do not bend, and the one route round it

The rule: we do not cut rooflights or skylights into thatch. There is no way to dress a flashing into a thatched surface the way it is dressed into tile or slate, thatch is a fire-spread consideration in its own right, and a thatched building in a Dorset village is very often listed as well. A firm that agrees to do it quickly is a firm to be wary of.

The route round it: a great many thatched cottages have a later addition — a rear extension, an outrigger, a garage conversion — under tile, slate or a flat deck. Where the dark room is under one of those, the job becomes ordinary and we can do it properly. Where the daylight is genuinely wanted under thatch, the honest answer is a dormer or an eyebrow window designed and built by people who work in thatch, which is not us, and we will say so rather than take the enquiry.

Shade, damp and debris: the real local variables

Lytchett Minster is green. Mature trees through the village, the wooded edges, the marsh and reedbed along the bay, and a lot of north-facing rear slopes on houses that face the road. That combination does three things to glazing, none of which a marine specification fixes.

Debris settles. Leaf fall, blossom, pine needles and seed all land on a rooflight and, on a shallow or flat unit, sit there until they dry into a mark. Self-cleaning glass works by needing rain to run off it, so it earns its cost on a pitched unit and rather less on a nearly flat one. We will tell you which of those you have before you pay the upgrade.

Algae and moss grow. Damp shade at the low end of a roof near reed and water is an ideal place for both, and the green film people notice on north-facing glazing in this village is usually biological rather than a failure of the unit. It cleans off. It also tells you something about how much daylight you are actually getting through that pane in February.

Condensation is not a leak, and the difference is diagnosable

A large share of the “my skylight is leaking” calls we take from sheltered, damp, tree-shaded locations are not leaks. They are condensation, and the two look identical to a worried homeowner at seven in the morning.

What you see Points to condensation Points to a genuine leak
Timing Cold still mornings, worse in winter, often with no rain at all During or shortly after rain, and worse in wind-driven rain
Where the water is On the inside face of the glass and running down the internal frame At the head of the opening, in the reveal plaster, or staining outwards from one corner
Between the panes Misting inside the sealed unit means a failed seal — the unit is spent, not the installation Not applicable; a leak does not get inside a sealed unit
The likely fix Ventilation, an insulated and broken cold bridge at the kerb or reveal, sometimes trickle ventilation The flashing detail, the upstand height, or the covering around the opening

A bare timber kerb on a flat roof is a cold bridge running right round the perimeter, and in February that produces water on the inside of the frame reliably enough to set your watch by. It gets reported as a leak, a firm is called out, and nothing is found. We insulate the kerb as standard for that reason and we explain it at handover.

Dorset Council decides here, not BCP

Which council, and what it changes

Lytchett Minster is in the Dorset Council area. Poole is in Bournemouth, Christchurch and Poole. The village looks towards Poole for shops, schools and traffic, and the planning goes the other way. Different portal, different local plan, different conservation officers, different Building Control team.

Until 2019 this was Purbeck District Council. The name is still in local use and is still attached to a great deal of out-of-date guidance online.

Usually permitted development: a rooflight or skylight in an existing roof slope projecting no more than 150mm beyond the plane of the roof and sitting below the highest part of the roof. Building Control is separate and is almost always needed, because you are altering structure and installing a thermal element.

Unless: the building is listed, the address is in a conservation area, an Article 4 direction applies, or a condition on an earlier consent removed permitted development rights. We check the boundary against your actual address rather than guessing from the village name. Where consent is needed it is decided on the merits and is never assured — we will not tell you an outcome and nor should anyone else.

What the survey settles

  1. The covering, identified on the roof. Tile, slate, flat deck or thatch — and whether there is a second covering on a later part of the building that changes the answer.
  2. Pitch, measured. The number that decides whether you are having a pitched roof window, a low-pitch range with a specific collar, or a flat rooflight on a kerb.
  3. The structure. Rafter or joist size and spacing, what trimming the opening needs, and whether an engineer is required rather than assumed.
  4. Zone and specification, written down. Sheltered marine, with the coating and fixing grade that follows, and no upgrade you do not need.
  5. Shade and orientation. Which way the slope faces, what overhangs it, and therefore whether self-cleaning glass is worth its cost on your roof.
  6. Constraints. Listing, conservation area, Article 4 or planning conditions, checked against the address.
  7. Access. Whether there is a side route to the rear roof or everything comes through the house, and whether the lane takes a delivery.
  8. A fixed written price, itemised, with any roof repair shown separately.

What we promise, and what we will not claim

Written, not implied

A ten-year workmanship guarantee on our installation work. It is a workmanship guarantee and it is not insurance backed, and we say so in plain words. Units and components carry their own manufacturer warranties, handed over with the paperwork.

A fixed written price after survey. One figure, not a range. If soft deck appears under an intact covering we stop, show you and price the repair separately before going on.

The firm is new and holds none of them.

We install and replace rooflights and skylights across Poole and about thirty miles around it. We are not thatchers, we are not general roofers, and in a village with as much older building stock as this one those limits come up often enough to be worth stating. Ring 01202 923272 to talk through what is on your roof.

Get a fixed quote

Tell us which way your roof faces.

We will come back with a specification, not a catalogue page. If your extension faces south we will tell you the G-value we would fit and why.

  • No pressure, no doorstep sales call
  • We handle the Building Control notification
  • 10-year workmanship guarantee on every installation
  • Installations and replacements across Poole and south Dorset

Prefer to talk it through? 01202 923272