Insulation collars, vapour collars and the order they go in
The collars around a roof window frame handle insulation, vapour control and stray water, and fitting them out of order or leaving one out causes damage that takes two winters to show.
Three separate collars go round a roof window frame. They do three different jobs, they sit in a fixed order from the inside out, and the one that gets left out is almost always the one nobody can see afterwards.
We write this up because it is the part of a roof window installation that is completely hidden by the time the plasterboard is on, and therefore the part where corners get cut without anyone noticing for two winters. It is also the part that has almost nothing to do with the window itself and everything to do with whether the room works.
Three collars, three different jobs
| Collar | Where it sits | What it is for | What happens without it |
|---|---|---|---|
| Vapour collar | Innermost, on the warm side, sealed to the room’s vapour control layer | Stopping moist indoor air reaching the cold frame perimeter | Condensation inside the construction, mould at the reveal, timber wetting from within |
| Insulation collar | Wrapped round the frame within the thickness of the roof | Closing the thermal gap between frame and rafter so the perimeter is not cold | A cold line round the window, condensation on the plaster, a draughty-feeling room |
| Underfelt or drainage collar | Outermost, on the cold side, dressed onto the roofing underlay | Taking any water that gets past the covering back out onto the underlay below | Stray water runs into the insulation and onto the ceiling, presenting as a leak |
The order, and why it is not negotiable
- Frame in, squared, fixed to the trimmers and checked against the diagonals. Nothing else happens until the frame is right.
- Underfelt collar dressed out onto the existing underlay, with the bottom edge lapped over it so water runs down and out, never behind.
- Flashing and covering made good outside, so the window is weathertight before anything warm is done.
- Insulation collar fitted round the frame, packed to the rafter, with no gaps at the corners.
- Vapour collar fitted on the room side and sealed continuously to the vapour control layer of the roof build-up.
- Lining battens, plasterboard reveal, then decoration.
The sequence follows the physics. Water is dealt with from the outside in; moisture in air is dealt with from the inside out. Doing the warm-side work before the cold-side work means someone has to go back through finished insulation to fix the underlay, and in practice that means it does not get fixed.
Warm side and cold side, in plain terms
Indoor air holds moisture. When it meets a surface cold enough, that moisture turns to water. In a roof build-up the layers get progressively colder as you move outward, so there is a point somewhere in the thickness where the air, if it reaches that far, will condense.
Everything built for the warm side, meaning the vapour collar and the vapour control layer it joins, exists to stop indoor air reaching that point. Everything on the cold side, meaning the underlay and the drainage collar, exists to let anything that does get there escape harmlessly outward. Reverse them and you have built a trap.
What a missing vapour collar looks like two winters later
It does not look like a leak, which is why it gets misdiagnosed. The signs are black spotting at the top corners of the reveal, paint lifting on the plasterboard return, a musty smell in still weather, and damp that is worst in cold dry spells rather than in rain. A leak follows the weather. A vapour failure follows the heating.
The reason this matters commercially is that the usual response is to re-seal the flashing outside, which does nothing, and then to replace the window, which also does nothing, because the water was never coming from outside. We diagnose this by when it appears rather than where it appears, and it is worth asking any firm that quotes you for a leak how they ruled interstitial condensation out.

The drainage collar is the one that gets skipped
Of the three, the underfelt collar is the one most often absent on installations done by a general builder rather than a roofer. It is fiddly, it is invisible the moment the insulation goes in, and the window is weathertight without it right up until the day it is not.
Its job is modest and vital. Some water will get past a tile covering in driving rain, particularly at a shallow pitch and particularly on an exposed elevation. The underlay carries that water down and out at the eaves. A window cut into the slope interrupts the underlay, and the collar is what restores the path round the interruption. Without it, the water that the underlay was carrying arrives at the top of your window opening and goes inside.
Insulation at the perimeter: the cold frame problem
A roof window frame is a thermal weak point by nature. It is a relatively thin section of timber or composite bridging the full thickness of an insulated roof, and the gap between it and the rafter is where cold gets in if it is left as an air space.
The insulation collar closes that gap and, just as importantly, does so without being compressed to nothing at the corners. Compressed insulation is not insulation. The corners are where installers run out of patience, and the corners are where the condensation appears, which is not a coincidence.
Two things that change on this coast
Wind-driven rain on exposed elevations. Out on the spit at Sandbanks and Studland, and along the exposed coast at Portland and Milford on Sea, the volume of water reaching the underlay in a south-westerly is far higher than it is in Broadstone. The drainage collar is doing real work there, and the lap onto the underlay is checked rather than assumed.
Humidity indoors. A coastal loft bedroom with the window shut for a fortnight in January is a humid room. The vapour collar is not optional anywhere, but the margin for a sloppy one is smaller here than inland.
Taping, and the joints nobody photographs
A vapour collar only performs if it is continuous. That means sealed to itself at the corners and sealed to the roof’s vapour control layer all round, with a proper tape rather than a bead of anything. A collar stapled up and left unsealed at the head is a collar that has been installed and is doing very little.
The same applies where the collar meets the frame. There is a designed detail for that junction and it is worth following, because the frame perimeter is exactly where warm air wants to go.

Retro-fitting a collar to a window already in
Mostly you cannot, not properly. What is and is not retrievable follows which side of the frame the collar sits on.
| Collar | Can it be added later? | What it takes |
|---|---|---|
| Vapour collar | Partly | Reveal lining off from inside, collar formed and taped, lining rebuilt and redecorated |
| Insulation collar | Usually | Same access as above; the gap to the rafter is packed while the reveal is open |
| Underfelt or drainage collar | Effectively no | Covering lifted, flashing off, and in practice the window out and back in |
This is why we treat the question honestly at survey. If a skylight has a condensation problem at the reveal, the reveal comes off and we look. If it has a water problem at the head in driving rain, that is a covering-side job and it will cost what it costs.
Why we photograph this stage
Every one of these layers is buried by the end of the day. We photograph the underlay collar before the flashing goes on, the insulation collar before the vapour collar, and the sealed vapour collar before the lining. You get the photographs whether you ask for them or not.
That is not a marketing gesture. It is the only record that the hidden two-thirds of the job was done, and in ten years’ time when someone else is looking at your roof it is the difference between an informed opinion and a guess.
Where this sits in the wider job
Recessed installation changes the frame position in the roof plane and therefore changes how the collars are packed; that is covered in its own guide. Choosing the flashing is a separate decision again, driven by your covering. What this page owns is the sequence, and the sequence is the same whether the unit is a centre-pivot rooflight in a Parkstone loft or a top-hung one in a Wareham cottage.
If you are getting quotes and want to know what to ask, ask each firm which three collars they will fit and in what order. Call 01202 923272. Our workmanship carries a ten-year guarantee, given directly and not insurance backed, on a price fixed in writing after survey.
Related reading
Can a VELUX be converted from manual to electric?
Usually yes, if the unit is from roughly the last twenty years. A retro-fit kit replaces the top control bar…
Can a VELUX be fitted to a flat roof?
Not as it comes. A standard pitched-roof unit needs a slope of roughly fifteen degrees or more to shed water…
Can a VELUX be fitted to a roof with solar panels?
Yes, but it stops being a roofing question and becomes a clearance and sequencing one. A flashing needs a clear…
Can a VELUX be replaced with the same size unit?
Usually yes. The standard size grid has been stable for decades, so a like-for-like frame is normally available, but “same…
Can a VELUX window be repaired?
Yes, more often than not. Glass, gaskets, filters, handles, friction components and flashings are all replaceable on their own. The…
Can I fit a blind to an old VELUX window?
Usually yes, provided you can read the size and type codes off the data plate. Manufacturer blinds are made to…