Who made my rooflight if there is no label on it?
Frequently nobody can say for certain, and it matters much less than people expect. What a replacement order actually needs is the unit described: measured opening, glazing method, rebate depth, spacer type and frame profile. The brand on the original is useful when it survives and rarely decisive when it does not.
Labels do not last on a skylight. They are stuck to a frame that sits in weather, or printed on a face that spent twenty years in sunlight, or painted over during a redecoration. On 1990s flat rooflights in particular, finding nothing is the normal outcome rather than the unlucky one.
Why the maker matters less than you think
Almost every flat glass rooflight and roof lantern sold today is manufactured to the customer’s dimensions. That means a replacement is specified to a measured opening rather than selected from a list, so the identity of the company that made the original is simply not on the critical path. The exception is where you need a part rather than a whole unit, and that is a narrower question dealt with further down.
Five places a mark survives
| Where to look | What is usually there | What it tells you |
|---|---|---|
| The spacer bar, seen through the glass | A code or date stamped or printed into the aluminium or polymer spacer | Often the manufacturing date of the sealed unit, and whether it is warm edge or plain aluminium |
| The toughening mark, etched in a corner | A small permanent sandblasted or acid-etched mark | The glass processor and the standard the pane was toughened to. No date |
| The underside of the frame | A printed label, sometimes with a works order number | The most useful of the lot when it survives, because an order number can be traced |
| The inner face of the kerb | A label applied at manufacture and then hidden by the upstand | Often legible precisely because it has been protected from light and weather |
| The house paperwork | Building control records, a completion certificate, a builder’s invoice | Dates the work even where it does not name the rooflight. BCP Council holds records for its area |
Roof windows in a pitched roof are a different case: those carry a manufacturer’s plate on the sash or frame, with its own conventions, and that has its own guidance elsewhere on this site.
Reading a toughening mark
The mark etched into one corner of a toughened pane is permanent, because it is applied before toughening. It normally identifies the processor that toughened the glass and cites the standard the pane was processed to. What it does not carry is a date, and what it does not tell you is who assembled the sealed unit or who made the rooflight, since a glass processor supplies many fabricators.
It is still worth photographing. It confirms the pane is toughened rather than annealed, which matters overhead, and combined with a spacer stamp it usually places the unit within a few years.
What a spacer code does and does not say
Read it as a date, not as a name
Many sealed units carry a mark on the spacer bar recording when and where the unit was assembled. Where the edge cover is shallow enough to see it, that is the single most useful thing on the whole rooflight, because it dates the failure and tells you whether the unit died early or reached the end of an ordinary life.
What it does not identify is the rooflight manufacturer. The company that made the sealed unit and the company that made the frame it sits in are usually different businesses. A spacer code answers “how old” far more reliably than it answers “who”.
What we record instead of a brand
- The opening, measured at the top of the kerb, both widths, both heights and both diagonals.
- The glazing method: bead, gasket, wet glazed or factory bonded, which decides whether a repair is even possible.
- The rebate depth and the available edge cover, which decides what make-up can go back.
- The overall unit thickness, read at the edge, which tells us what the original specification was.
- The frame profile and finish, photographed in section where we can, since profiles date a system fairly accurately.
- The kerb construction, height, insulation and fall, because those are as much a part of the specification as the glass.
The 1990s extension, where there never was a brand
A great many Poole rooflights were bespoke from the first day. On extensions built through the 1990s and early 2000s, the carpenter formed an upstand from whatever the joists and the timber allowed and glass was ordered afterwards to suit it. There was no catalogue product, no model name and no label, because none of those things ever existed. Owners sometimes spend a long time looking for a manufacturer that was never involved. A measured opening and a current, supported product is a better outcome than a nominal match to something untraceable, and it is what we would specify anyway.
When the maker genuinely does matter
Three situations. Where you want a single failed unit to match a run of others that are staying, in which case the frame profile and finish matter more than the name, but the name helps. Where the rooflight opens and you need gear, gaskets or an actuator rather than glass, since those are system-specific and a discontinued system is a real problem. And where a guarantee is still live, which on a twenty-year-old unit it will not be, but on a ten-year-old one is worth checking before anyone touches it.
What to photograph
Each corner from inside, close and with the flash, which sometimes catches a spacer stamp or a toughening mark. The frame edge showing the beads or gaskets. The underside of the frame where a label may still be. The reveal and upstand from inside. Send them to 447880284133 or ring 01202 923272 with your address. If the maker cannot be identified we will say so plainly rather than guess, and specify to the measured opening instead. The survey ends in a fixed written price, and our installation carries a ten-year workmanship guarantee given directly by us, which is not insurance backed.
Related reading
Are 1990s rooflights on Poole extensions worth replacing now?
In most cases yes, and usually not for the reason people expect. A 1990s unit that has misted is finished…
Can a leaking rooflight be resealed instead of replaced?
Sometimes, where the leak is at a gasket, a termination or a joint that can genuinely be renewed. But the…
Can a misted rooflight be repaired?
Sometimes, but not in the way most people mean. The misting itself cannot be cured, because the fault is inside…
Can a misted unit be replaced with a larger one?
Yes, and it is often worth doing while the roof is open. But be clear what you are agreeing to:…
Can a rooflight be replaced in one day?
The fitting usually is, yes. One rooflight, on a roof that can be reached, onto a kerb that turns out…
Can an old dome rooflight be swapped for flat glass?
Yes, and it is one of the replacements people are most pleased with afterwards. The work is usually straightforward, because…