The short answer

Four things make a rooflight look cloudy, and only one of them is a failed sealed unit. Wipe both faces of the glass: if the haze disappears it was condensation or dirt, and if it survives a wipe on both sides it is either between the panes, etched into the outer surface, or in the material itself.

How a sealed unit fails and mistsA sealed unit holds dry air or argon between two panes, kept dry by desiccant in the spacer bar. Daily heating and cooling pumps the cavity; once the edge seal loses its grip, moist air is drawn in, the desiccant saturates, and the misting that appears between the panes cannot be cleaned because it is on the inside.cavity: dry air or argonspacer with desiccantedge sealmisting sits between the panes, so it cannot be cleaned offmoist air

People almost always arrive at this question having assumed the answer is a failed unit. About a third of the time it is not, so it is worth spending five minutes ruling the others out before spending anything else.

Do this first

  1. Wipe the inside face with a dry cloth. If it clears, it was surface condensation on the room side and the skylight has not failed.
  2. If you can reach the outside safely from a window or a landing, wipe that too. Never go onto a roof to check. If it clears, it was dirt, salt film or dew.
  3. Look again mid-morning once the sun has been on the glass for an hour, and again late afternoon. Haze that comes and goes with temperature is a cavity failure in its early stage.
  4. Look at where it starts. A bloom in one corner, a band along the bottom edge and an even haze across the whole pane mean different things.
  5. Check whether the glass is actually glass. Tap it: a polycarbonate dome sounds and feels quite different, and it fails in a different way entirely.

The four causes, and how to tell them apart

Cause What it looks like Does wiping help? Is it a fault?
Failed edge seal Bloom or haze trapped between the panes, often worst at a corner or the low edge No, from either side Yes, of the sealed unit. The frame and kerb may be perfectly sound
Surface condensation Even film on the room side on cold mornings, worst in kitchens and bathrooms Yes, immediately No. It is humidity and ventilation, though an old unit runs colder and makes it worse
Degraded polycarbonate A yellow or milky cast across a dome, with fine crazing visible at an angle No. The material itself has changed Yes, and it is terminal. A dome cannot be re-glazed
Etched or scoured outer surface A dull, slightly milky face that catches the light unevenly No, and abrasive cleaning made it worse Yes, of the glass surface. The unit may still be perfectly sealed

If it is the sealed unit

Then the fault is inside a factory-made component: two panes held apart by a spacer packed with desiccant, closed by a thin inner seal that keeps vapour out. Once that seal thins, the daily warming and cooling of the cavity pumps damp air in and out, the desiccant saturates, and the cavity starts dewing at whatever temperature suits it. Nothing reaches it from either side. The unit is replaced, and on a mechanically glazed frame that often means new glass in the frame you already have.

If it clears when you wipe it

Then the rooflight has not failed and the moisture is in the room. Overhead glazing shows this before anything else in the house does, because it is the coldest surface in the room and warm moist air rises to meet it. Kitchens, bathrooms, rooms with a drying rack under the skylight and homes where trickle vents have been closed all produce it reliably. An old single-glazed or air-filled unit runs colder than a current one and will dew more readily, which is a fair argument for replacement, but the water is still coming from inside the house.

If it is a dome

Polycarbonate does not mist, it degrades

A twin-wall or triple-wall polycarbonate dome has no sealed cavity to fail. What happens instead is that ultraviolet breaks down the material from the outer surface in. It yellows, loses clarity, develops fine surface crazing and eventually goes brittle enough that a foot or a falling branch will go through it.

There is no repair and no restoration. A degraded dome is replaced, and on Poole estate extensions with domes from the 1990s and early 2000s it is one of the few replacements nobody afterwards wishes they had put off.

If the outer surface is etched

This one catches people out because the unit is often still perfectly sealed. A glass surface can be dulled by abrasive cleaning, by wind-blown sand on an exposed coastal roof, or by hard water and cleaning products left to dry in the sun. On self-cleaning glass, using the wrong cleaner or a scouring pad damages the coating permanently and leaves a patchy haze that looks very like a failed seal from below. It is worth identifying, because replacing a sealed unit will not fix a surface problem and a surface problem sometimes means only the outer pane needs attention.

What it means for the room either way

A misted skylight is not an emergency. It is unattractive, it cuts the daylight noticeably once the haze is even, and a unit old enough to have failed is losing more heat than a current one. It is not a leak, it does not make the roof less weathertight, and there is no safety issue in leaving it until spring. We would rather say that than manufacture urgency.

What to send us

  1. One photograph from inside, square on, room lights off and daylight behind the glass, which shows how far the haze has spread.
  2. A close shot of each corner from inside, since that is where a seal failure starts and where tide marks collect.
  3. One of the ceiling and reveal around the opening, which tells us whether anything else is going on.
  4. Your address, so we can name the exposure zone the roof sits in before anyone comes out.

Send them to 447880284133 or ring 01202 923272 and we will tell you which of the four we think you are looking at. The survey is what produces a fixed written price, and our own work carries a ten-year workmanship guarantee given directly by us, which is not insurance backed.

Get a fixed quote

Get a fixed quote

Tell us which way your roof faces.

We will come back with a specification, not a catalogue page. If your extension faces south we will tell you the G-value we would fit and why.

  • No pressure, no doorstep sales call
  • We handle the Building Control notification
  • 10-year workmanship guarantee on every installation
  • Installations and replacements across Poole and south Dorset

Prefer to talk it through? 01202 923272